VIPER 186731835Recalls & reported problems
Medos International Sàrl · VIPER SYSTEM CORTICAL FIX POLYAXIAL SCREW 5.5 8 x 35mm · Class 2 · Implant
All models of VIPER (121)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034352176), received between Nov 5, 2020 and Nov 5, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
Patient problems
- Failure of Implant1
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 5, 2020Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2019 THE PATIENT UNDERWENT THE PRIMARY PROCEDURE IN THE LUMBAR SPINE TREATING TUBERCULOUS SPONDYLITIS. ON (B)(6) 2020 IT WAS REPORTED THAT THIS WAS A PPS (PERCUTANEOUS PEDICLE SCREW FIXATION) REVISION PROCEDURE AT L1-SAI REPLACING BROKEN-OFF RODS AND EXTENDING ROD RANGE. DURING THE REVISION AN IMPLANTED SCREW AT S1 RIGHT WAS REPLACED. IT WAS DIFFICULT TO RECONNECT THE RODS SO THE NEW SCREW WAS GOING TO BE REMOVED WITH A DRIVER SHAFT. THE DRIVER SHAFT¿S TIP BROKE OFF DUE TO THE PATIENT¿S ROBUST BONE QUALITY. THE FRAGMENT STUCK IN THE SCREW SO THE ROD WAS CUT IN THREE (3)CM LONG PIECES. THE THREE (3)CM PIECE WITH THE SCREW WAS ATTEMPTED TO BE REMOVED WHEN THE SCREW MOVED AND THE FRAGMENT WAS REMOVED. ANOTHER DRIVER SHAFT WAS USED TO REMOVE THE THREE (3)CM PIECE AND THE SCREW, BUT THE TIP OF THE DRIVER SHAFT BROKE OFF TOO. THE FRAGMENT WAS REMOVED AND THE SCREW REMAINED IN THE PATIENT¿S BODY. THE ROD WAS REPLACED AND IMAGING FOUND SOME FOREIGN OBJECTS (POSSIBLY FRAGMENTS) AT S1 LEFT (CLOSE TO THE PEDICLE). TWO PIECES WERE REMOVED, BUT THE POSTOPERATIVE X-RAY SHOWED ONE MORE FRAGMENT IN THE PATIENT¿S
Patient problems: Failure of Implant; No Code Available
MAUDE report 10793666 ↗
Other Orthosis, spinal pedicle fixation, for degenerative disc disease devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page