VIPER PRIME 286750082Recalls & reported problems
Medos International Sàrl · VIPER PRIME COMPRESSOR DRIVER LEG · Class 1
All models of VIPER PRIME (60)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 4
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10705034507729), received between Dec 31, 2019 and Mar 7, 2023 — classified as 1 injury, 3 malfunctions.
The most frequently reported specific device problem is “Break” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break2
- Device-Device Incompatibility2
- Contamination /Decontamination Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Code Available1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 7, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2023, DURING A PLIF FOR THE LUMBAR STENOSIS BEFORE STERILIZATION, STEIN WAS FOUND IN THE HOLLOW PART OF THE DEVICES. THE DEVICES WERE DELIVERED ON THE OPERATION DAY, AND THE SURGEON DETERMINED THAT IT WOULD TAKE TIME TO CLEAN. THEREFORE, OTHER SAME DEVICES WERE USED. PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT ANY SURGICAL DELAY. THIS REPORT IS FOR ONE (1) VIPER PRIME COMP DRIVER LEG. THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16496513 ↗MalfunctionJul 19, 2022Break; Break
DEVICE REPORT FROM JAPAN REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2022 DURING A PROCEDURE FOR PERCUTANEOUS POSTERIOR THORACOLUMBAR FUSION, THE DRIVER LEG WAS UNABLE TO BE DETACHED FROM AN UNKNOWN SCREW. THE DRIVER LEG WAS MOUNTED ONTO THE COMPRESSOR DRIVER AND APPLIED COMPRESSION TO TH11. A DRIVER SOLID LEG AS APPLIED TO TH12 FOR COMPRESSION AS WELL. AFTER THE COMPRESSION WAS APPLIED, WHEN THE SURGEON TRIED TO DETACH THE DRIVER LEG, THEY COULD NOT. THE DRIVER LEG AND SCREW WERE STUCK TOGETHER TIGHTLY. THE PROCEDURE WAS COMPLETED WITHOUT SURGICAL DELAY. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT IS FOR A VIPER PRIME COMPRESSOR DRIVER LEG. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15055208 ↗MalfunctionMar 18, 2020Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2019 DURING AN UNKNOWN PROCEDURE IT WAS DIFFICULT TO DETACH THE DRIVER LEG (286735400) FROM THE IMPLANTS. THE PROCEDURE WAS DELAYED. CONCOMITANT DEVICE: UNKNOWN SCREW (PART# UNKNOWN, LOT# UNKNOWN, QUANTITY 1). THIS REPORT IS FOR ONE VIPER PRIME COMP DRIVER LEG. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9848639 ↗InjuryDec 31, 2019Break; Device-Device Incompatibility; Break; Device-Device Incompatibility
DEVICE REPORT FROM (B)(6) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2019 DURING A TLIF (TRANSFORAMINAL LUMBAR INTERBODY FUSION) TO TREAT A SPINAL CANAL STENOSIS THAT AFTER INSERTING THE DRIVER LEG (286750082), THE SURGEON PUT COMPRESSION AND TRIED TO REMOVE IT FROM THE TABS BUT THE DRIVER LEG WAS NOT ABLE TO BE REMOVED. THE SURGEON BROKE OFF THE TABS TO SUCCESSFULLY REMOVE THE DRIVER LEG BREAKING THE SCREW'S TABS. THE PROCEDURE WAS COMPLETED WITH LESS THAN 30-MINUTE SURGICAL DELAY. THIS REPORT IS FOR ONE VIPER PRIME COMP DRIVER LEG. THIS IS REPORT 2 OF 2 FOR PC-(B)(4).
Patient problems: No Code Available
MAUDE report 9535720 ↗
Other INSTRUMENT, COMPRESSION devices
- ATTUNE 2545-01-042Depuy (Ireland) · INSTRUMENT, COMPRESSION153 reports
- ATTUNE 2545-11-041Depuy (Ireland) · INSTRUMENT, COMPRESSION78 reports
- ATTUNE 2545-05-550Depuy (Ireland) · INSTRUMENT, COMPRESSION54 reports
- ATTUNE 2545-05-551Depuy (Ireland) · INSTRUMENT, COMPRESSION34 reports
- NA 03.111.021Synthes GmbH · INSTRUMENT, COMPRESSION32 reports
- ATTUNE 2545-05-552Depuy (Ireland) · INSTRUMENT, COMPRESSION27 reports
- NA 03.211.400Synthes GmbH · INSTRUMENT, COMPRESSION25 reports
- VIPER PRIME 286750083Medos International Sàrl · INSTRUMENT, COMPRESSION18 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page