VIPER PRIME 186760245Recalls & reported problems

Medos International Sàrl · VIPER PRIME X-TAB POLYAXIAL SCREW 5.5 6 x 45mm · Class 2 · Implant

All models of VIPER PRIME (60)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034509266), received between Nov 9, 2020 and Nov 9, 2020 — classified as 1 malfunction.

The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Device-Device Incompatibility1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 9, 2020Device-Device Incompatibility; Device-Device Incompatibility

    IT WAS REPORTED THAT ON (B)(6) 2020, DURING AN UNKNOWN PROCEDURE, THE SURGEON WAS PLACING THE L5 PEDICLE SCREW ON THE PATIENT'S RIGHT USING THE VIPER PRIME SYSTEM. WHEN THE SURGEON CONFIRMED THE TIP OF THE SCREW/DRIVER ASSEMBLY WAS PROPERLY POSITIONED VIA INTRA-OPERATIVE FLUORO, HE ADVANCED THE PRIME STYLET APPROXIMATELY 3MM IN THE PEDICLE AND USED A MALLET TO ADVANCE THE EXTENDED STYLET UNTIL IT WAS FULLY SEATED. THE SURGEON FELT THAT WHEN HE DEPLOYED THE STYLET TO APPROXIMATELY 15MM, HE WAS UNABLE TO CONTINUE TO ADVANCE THE STYLET DUE TO HARD BONE. THE SURGEON CONFIRMED WITH INTRO-OPERATIVE FLUORO THAT THE STYLET WAS NOT ADVANCING, AND IT BECAME EVIDENT FROM THE IMAGE THAT THE STYLET WAS BENT AT THE DISTAL END OF THE SCREW. THE SURGEON ATTEMPTED TO REMOVE THE SCREW/DRIVER/STYLET ASSEMBLY FROM THE PEDICLE. ONCE REMOVED FROM THE INCISION, THE STAFF ATTEMPTED TO REMOVE THE BENT STYLET FROM THE SCREW/DRIVER ASSEMBLY. WHILE THE STAFF CONTINUED TO ATTEMPT TO REMOVE THE BENT STYLET, THEY ASSEMBLED A NEW DRIVER/STYLET, AND PROCEEDED TO LOAD A NEW 6.0X45MM PRIME SCREW. THE SURGEON INSERTED THE NEW SCREW WITH NEW DRIVER ASSEMBLY WITH NO FURTHER ISSUES. AFTER THE PROCEDURE WAS COMPLETED, TH

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10809285 ↗

Other Thoracolumbosacral pedicle screw system devices

All Thoracolumbosacral pedicle screw system devices →