SYMPHONY 1020-24-003SRecalls & reported problems

Medos International Sàrl · SYMPHONY OCT SYSTEM CROSSCONNECTOR ROD TO ROD 32 to 35mm · Class 2 · Implant

All models of SYMPHONY (113)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10705034520216), received between Jan 27, 2023 and Nov 8, 2023 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Device-Device Incompatibility” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 1 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Device-Device Incompatibility2
  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Pocket Erosion1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 8, 2023Device-Device Incompatibility; Device-Device Incompatibility

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN AUSTRALIA AS FOLLOWS: IT WAS REPORTED THAT THE SURGEON HAD REQUESTED A ROD TO ROD CROSS CONNECTOR FOR THE SYMPHONY POSTERIOR CERVICAL SYSTEM. THE SCRUB NURSE INADVERTENTLY DISASSEMBLED THE CONNECTOR, AND WHEN SHE CHOSE THE NEXT SIZE, THE SAME THING HAPPENED. THE THIRD (3RD) CONNECTOR WAS CHOSEN, BUT THIS TIME, THE SET SCREW APPEARED TO BE UNMOVABLE. THE SURGEON SUBSEQUENTLY DECIDED NOT TO USE A CONNECTOR. THIS WAS NOT BECAUSE OF THE ISSUES THAT HAD OCCURRED. THE IMPLANTS WERE NOT USED, AND THE SURGEON HAD ALSO DECIDED NOT TO USE THE IMPLANTS. THEY WERE "DAMAGED OR DISASSEMBLED" PRIOR TO HIS DECISION. NO FRAGMENTS WERE GENERATED. THERE WAS NO SURGICAL DELAY DUE TO THE REPORTED EVENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. OTHER INFORMATION: SURGEON HAD DECIDED THAT HE DID NOT WANT TO USE A ROD TO ROD CONNECTOR. THERE WERE NO PATIENT OUTCOMES OR CONSEQUENCES. THIS REPORT IS FOR ONE (1) CROSSCONN R2R 32 TO 35MM. THIS IS REPORT 2 OF 3 FOR COMPLAINT (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18093661 ↗
  • MalfunctionMar 28, 2023Device-Device Incompatibility; Device-Device Incompatibility

    THE CROSS CONNECTOR WAS REPLACED WITH A NEW PRODUCT OF THE SAME PRODUCT CODE TO COMPLETE THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16629587 ↗
  • InjuryJan 27, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN JAPAN AS FOLLOWS: IT WAS REPORTED THAT THE PATIENT UNDERWENT SPINAL FUSION FOR DEGENERATIVE DISEASE ON (B)(6) 2022. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHOUT ANY DELAY. AFTER THE SURGERY, THE CROSS-LINK WAS REMOVED DUE TO PRESSURE ULCER. THE PATIENT OUTCOME WAS REPORTED TO BE STABLE, AND IT WAS REPORTED THAT THERE WAS NO ADVERSE CONSEQUENCE THAT AFFECTED THE PATIENT. NO FURTHER INFORMATION IS AVAILABLE. THIS REPORT INVOLVES ONE SYMPHONY OCT SYSTEM CROSSCONNECTOR ROD TO ROD 32 TO 35MM. THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: Pocket Erosion

    MAUDE report 16252414 ↗

Other APPLIANCE, FIXATION, SPINAL INTERLAMINAL devices

All APPLIANCE, FIXATION, SPINAL INTERLAMINAL devices →