VIPER PRIME 186770330SRecalls & reported problems
Medos International Sàrl · VIPER PRIME CFX X-TAB POLYAXIAL SCREW 5.5 7 x 30mm · Class 2 · Implant
All models of VIPER PRIME (60)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034530154), received between Dec 6, 2024 and Dec 6, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Migration1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 6, 2024Migration; Migration
IT WAS REPORTED THAT THIS WAS A POSTERIOR SPINAL FUSION (L2-4) WITH VIPER PRIME AND VIPER PRIME FENESTRATED SCREWS FOR OSTEOPOROTIC VERTEBRAL FRACTURE ON (B)(6) 2024. THE VIPER PRIME CFX XTAB IN QUESTION WAS USED IN L3, AND THE FINAL TIGHTENING WAS DONE ACCORDING TO THE SURGICAL TECHNIQUE. WHEN BREAKING THE TAB AWAY, THE TAB AT L3 DID NOT BREAK AWAY SMOOTHLY, SO THE SURGEON FELT SOMETHING WAS WRONG AND CHECKED WITH AN IMAGE INTENSIFIER, WHICH CONFIRMED THAT THE SCREW PART OF THE VIPER PRIME CFX XTAB ON THE LEFT SIDE OF L3 CUT OUT. ONCE THE ROD ON THE LEFT SIDE WAS REMOVED, THE VIPER PRIME CFX XTAB IN L3 SCREW WAS EXTRACTED, AND THE INSERTION TO L3 WAS SKIPPED AND RE-FIXED. THE SURGERY WAS COMPLETED SUCCESSFULLY WITHIN 30 MINUTES DELAY. THE PATIENT OUTCOME WAS REPORTED TO BE STABLE. THE SURGEON COMMENTED AS FOLLOWS: IT WAS SUSPECTED THAT A FAULTY SCREW OR SET SCREW PREVENTED THE SCREW FROM SECURING TO THE ROD, AND THAT THE LOAD ON THE SCREW DURING TAB BREAKING CAUSED THE SCREW TO ROTATE OUTWARD AND CUT THE SCREW OUT OF THE VERTEBRAL BODY. HOWEVER, IT WAS IMPOSSIBLE TO DETERMINE THE OBVIOUS CAUSE OF THE EVENT. THE PATIENT HAD POOR BONE QUALITY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20865793 ↗
Other APPLIANCE, FIXATION, SPINAL INTERLAMINAL devices
- EXPEDIUM 179702000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL439 reports
- EXPEDIUM VERSE 199721001Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL227 reports
- XIA 3 48230000Stryker Corporation · APPLIANCE, FIXATION, SPINAL INTERLAMINAL193 reports
- VIPER 186715000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL1 death167 reports
- NA 04.614.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL80 reports
- NA 04.615.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- EXPEDIUM VIPER 196789480Depuy Spine, LLC · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- Arsenal Deformity Spinal Fixation System 47127Alphatec Spine, Inc. · APPLIANCE, FIXATION, SPINAL INTERLAMINAL66 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page