Skip to content

N/A 302015100Recalls & reported problems

Medos International Sàrl · UNIVERSAL NAVIGATION ADAPTOR SET NAVIGATION ARRAY VIOLET 4 SPHERES · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034536217), received between Nov 19, 2024 and Nov 19, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Material Deformation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 19, 2024Material Deformation; Material Deformation

    IT WAS REPORTED THAT ON (B)(6) 2024, WHILE NAVIGATING AN MIS SPINE CASE, T12-L5 TUMOR AT L3, A SCREW, AT T12 LEFT SIDE, ENDED UP IN THE LATERAL MOST PART OF THE SPINAL CANAL ACCORDING TO A LOOP-X 3D SCAN, WHILE ALL OTHER SCREWS, INCLUDING RIGHT T12, WERE IN EXPECTED LOCATIONS. THE SPINOUS PROCESS CLAMP WAS PLACED AT L5 AND THE PATIENT WAS REGISTERED USING LOOP-X AIR. ACCURACY WAS CHECKED WITH THE POINTER AT L5 AND ACCEPTED. THE ONLY NAVIGATED INSTRUMENT USED DURING THIS CASE WAS THE DEPUY SYNTHES VIPER PRIME, WHICH WHEN REGISTERED SHOWED A TIP DEVIATION BETWEEN 0.0-0.2MM AND THE INSTRUMENT ARRAY WAS CONFIRMED TO BE TIGHTLY ON THE INSTRUMENT. THE DOCTOR STARTED AT T12 ON THE RIGHT SIDE, HOWEVER DUE TO THE PATIENT'S DIFFICULT ANATOMY THE DOCTOR HAD A TOUGH TIME GETTING THE SCREW TO TAKE HOLD AND DECIDED TO SWITCH SIDES. BEFORE NAVIGATING THE OTHER SIDE, ACCURACY WAS CHECKED AND FOUND TO BE ACCURATE AT L5. THE LEFT SIDE OF T12 WAS ALSO DIFFICULT BUT THE DOCTOR WAS ABLE TO GET THE SCREW INTO BONE WITH ENOUGH FORCE. THE PATIENT WAS INVOLVED, BUT THERE WAS NO DELAY OF SURGERY AND NO NEGATIVE EFFECTS. LEFT T12 SCREW ENDED UP IN THE SPINAL CANAL, ROUGHLY ONE SCREW OVER MEDIAL TO WHAT WAS P

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20725755 ↗

Other Orthopedic stereotaxic instrument devices

All Orthopedic stereotaxic instrument devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page