Skip to content

VELYS 451611002Recalls & reported problems

Medos International Sàrl · VELYS™ Camera Station · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034646015), received between Aug 4, 2025 and Aug 4, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Positioning Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Positioning Failure1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 4, 2025Positioning Failure; Positioning Failure

    IT WAS REPORTED THAT DURING A SINGLE POSITION LATERAL SPINE PROCEDURE; THERE WAS SPIN WITH CO SYSTEM WHICH CUT OFF ANTERIOR PORTIONS OF THE BODIES. TRYING TO INSTRUMENT SCREWS. CUT OFF THE COUNT DOWN OF THE MEASUREMENTS TO THE DISTAL TIP. SECOND ISSUE WAS A DEVIATED SCREW THE L4 RIGHT SCREW. THE ARM WAS GREEN AND THE PROJECTION WAS SLIGHT OFF PLANNED SCREW. TROUBLESHOOTING: STILL WITHIN PARAMETERS BUT EXCESSIVE PRESSURE WARNING. THERE WAS EXCESSIVE PRESSURE WITH DRIVER BUT WOULD BACK IT OUT, PLACE KNIFE DOWN AGAIN TO MINIMIZE SOFT TISSUE BUT ONCE DRIVER WAS ENTERED THERE WAS EXCESSIVE FORCE ON AND OFF. PUT THE DRIVER IN AND DEVIATED BY A COUPLE MILLIMETERS - 3MM LATERAL 3MM SUPERIOR. SCREW WAS LATERAL AND SUPERIOR TO PLAN BUT STILL CLINICALLY A SAFE SCREW. SCREW POSITION WAS CONFIRMED BY CIOS SPIN. THERE WERE NO REPORTS OF INJURIES, MEDICAL INTERVENTION OR PROLONGED HOSPITALIZATION. PATIENT TREATMENT WAS NOT DELAYED OR CANCELLED.

    Patient problems: Insufficient Information

    MAUDE report 22698019 ↗

Other Orthopedic stereotaxic instrument devices

All Orthopedic stereotaxic instrument devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.