NA 03.820.115Recalls & reported problems
Synthes (U.S.A.) LP · MILLING GUIDE 6MM · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034731568), received between May 2, 2019 and May 2, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 2, 2019Break; Break
IT WAS REPORTED THAT DURING CERVICAL TOTAL DISC REPLACEMENT PROCEDURE ON (B)(6) 2019, THE MILLING DRILL GUIDE BROKE OFF. WHEN THE SURGEON ATTEMPTED TO CUT THE SUPERIOR KEEL, THE DRILL GUIDE BROKE AT THE PROXIMAL PART OF THE TUBE, WHERE THE MILLING BIT IS INSERTED. ALTHOUGH IT WAS NOT IMMEDIATELY CLEAR HOW THE MALFUNCTION OCCURRED, THE BEARINGS WERE OBVIOUSLY DAMAGED. THE SURGEON REMOVED THE ENTIRE DRILL GUIDE WITH THE MILLING BIT STILL IN THE TUBE TO PREVENT ANY METAL BITS FROM GETTING INTO THE PATIENT. ONCE ON THE BACK TABLE, THE DAMAGED INSTRUMENT AND FRAGMENTS WERE PUT INTO A PLASTIC BAG. THE SURGEON CHECKED VISUALLY ON X-RAY TO CONFIRM THAT NO DEBRIS WAS LEFT BEHIND IN THE PATIENT'S BODY. THERE WAS NO SURGICAL DELAY, AND THE SURGEON COMPLETED THE KEEL CUT USING 6MM CHISELS. THERE WAS NO HARM TO THE PATIENT. CONCOMITANT DEVICES: MILLING BIT (PART: 03.820.153S, LOT: H497433, QUANTITY: 1). THIS REPORT IS FOR A MILLING GUIDE 6MM. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8573585 ↗
Other Guide, surgical, instrument devices
- NA 03.037.017Synthes GmbH · Guide, surgical, instrument346 reports
- EVOS 71174934Smith & Nephew, Inc. · Guide, surgical, instrument149 reports
- LCP 323.042Synthes GmbH · Guide, surgical, instrument129 reports
- DJO SURGICAL 342-10-705Encore Medical, L.P. · Guide, Surgical, Instrument1 recall51 reports
- DJO SURGICAL 341-10-707Encore Medical, L.P. · Guide, Surgical, Instrument81 reports
- NA 03.010.404Synthes GmbH · Guide, surgical, instrument73 reports
- DJO SURGICAL 341-14-708Encore Medical, L.P. · Guide, Surgical, Instrument1 recall22 reports
- DJO SURGICAL 341-10-711Encore Medical, L.P. · Guide, Surgical, Instrument1 recall16 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page