NA 04.601.000Recalls & reported problems

Synthes GmbH · 90 DEG TI S-HOOK/RIGHT · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034734231), received between Dec 27, 2017 and Dec 27, 2017 — classified as 1 injury.

The most frequently reported specific device problem is “Break” (1 report).

1 other recall cover devices cleared under the same FDA submission (K142587); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • Failure of Implant1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 27, 2017Break; Break

    IT WAS NOTED THE PATIENT WAS STABLE FOLLOWING SURGERY. INITIALLY IT WAS REPORTED THE PELVIC HOOK FRACTURED INTO PIECES THAT WERE DIFFICULT TO REMOVE. DURING THE INVESTIGATION IT WAS NOTED IT WAS ALSO FOUND TO BE BENT AND HAS NICKS AND GOUGES ACROSS THE BALANCE OF THE DEVICE.

    Patient problems: Failure of Implant

    MAUDE report 7148579 ↗

FDA clearance and classification

Cleared through 510(k) K142587 on Nov 18, 2014 (decision: Substantially Equivalent). Submitted by Depuy Synthes Spine, Inc. as “Vertical Expandable Prosthetic Titanium Rib”. The FDA review took 64 days. FDA record ↗

The FDA regulates product code MDI (prosthesis, rib replacement) under 21 CFR 888.3070 as a Class II device. 21 CFR 888.3070 ↗

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Recalls under the same FDA submission

These recalls involve devices cleared under K142587. One submission often covers many models, so check the product and lot details in each record.

  • Z-2488-2015 · Jul 29, 2015 · Terminated
    VEPTR Vertical Expandable Prosthetic Titanium Rib, inferior cradles also known as caudal rib supports. The VEPTR/VEPTR II devices mechanically stabilize and/or correct thoracic de

Common questions about the NA 04.601.000

Has the NA 04.601.000 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10705034734231), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the NA 04.601.000?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Dec 27, 2017. That report lists device problem “Break” (1); patient problem “Failure of Implant” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the NA 04.601.000?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the NA 04.601.000 FDA approved?

It was cleared through 510(k) K142587 on Nov 18, 2014. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Is the NA 04.601.000 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the NA 04.601.000, and is it still sold?

The FDA's device database lists Synthes GmbH as the company responsible for it (brand NA, model 04.601.000). Its record shows it as in commercial distribution.