NA 498.140Recalls & reported problems
Synthes GmbH · 6.0MM TI CURVED SOFT ROD 55MM · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10705034789002), received between May 10, 2019 and May 10, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Failure of Implant1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 10, 2019Break; Break
DEVICE REPORT FROM SYNTHES (B)(4) REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT ON (B)(6) 2019, THE PATIENT UNDERWENT A PROCEDURE TO REMOVE BROKEN IMPLANTS. THE DEVICES WERE IMPLANTED YEARS AGO. THE PATIENT REPORTEDLY EXPERIENCED A LOT OF PAIN AND UNDERWENT MANY TREATMENTS SUCH AS INFILTRATIONS AND BLOCKAGES AS WELL AS RADIOFREQUENCY FOR PAIN, BUT THE CAUSE OF THE PAIN WAS NEVER FOUND. IT WAS DECIDED TO OPERATE TO SEE IF ANYTHING IN SITU COULD BE THE CAUSE OF THE PAIN. A BROKEN CLICKX ROD AT THE HEIGHT OF THE MIDDLE SCREW ON THE RIGHT SIDE AND A BROKEN CLICKX LOCKING CAP OF THE UPPER SCREW WERE DISCOVERED. THERE WERE FRAGMENTS GENERATED FROM THE BROKEN DEVICE AND THEY WERE REMOVED EASILY. THE CLICKX ROD AND THE CLICKX LOCKING CAP TO WERE CHANGED TO COMPLETE THE PROCEDURE. THERE WAS NO SURGICAL DELAY. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THE PATIENT STATUS WAS UNKNOWN. CONCOMITANT DEVICE REPORTED: SCREW (PART/LOT UNKNOWN, QUANTITY 1). THIS REPORT IS FOR A CLICKX ROD. THIS IS REPORT 1 OF 2 FOR (B)(4).
Patient problems: Failure of Implant; Pain
MAUDE report 8601440 ↗
Other APPLIANCE, FIXATION, SPINAL INTERLAMINAL devices
- EXPEDIUM 179702000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL439 reports
- EXPEDIUM VERSE 199721001Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL227 reports
- XIA 3 48230000Stryker Corporation · APPLIANCE, FIXATION, SPINAL INTERLAMINAL193 reports
- VIPER 186715000Medos International Sàrl · APPLIANCE, FIXATION, SPINAL INTERLAMINAL1 death167 reports
- NA 04.614.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL80 reports
- EXPEDIUM VIPER 196789480Depuy Spine, LLC · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- NA 04.615.014Synthes GmbH · APPLIANCE, FIXATION, SPINAL INTERLAMINAL72 reports
- Arsenal Deformity Spinal Fixation System 47127Alphatec Spine, Inc. · APPLIANCE, FIXATION, SPINAL INTERLAMINAL66 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.