LF 844007Recalls & reported problems
Liebel-Flarsheim Company LLC · OptiVantage Dual-Head CT Contrast Delivery System, OEM Interface · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10746190002727), received between Oct 24, 2024 and Dec 22, 2025 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
1 other recall cover devices cleared under the same FDA submission (K063503); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Pressure Problem1
Patient problems
- Administration Site Reaction1
- Extravasation1
- No Clinical Signs, Symptoms or Conditions1
- Pain1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 22, 2025Break; Break
THIS CASE WAS REPORTED BY A FACILITY IN (B)(6) ON (B)(6) 2025. CUSTOMER REPORTED THAT ON (B)(6) 2025, A PATIENT UNDERWENT CEREBRAL ARTERY CTA EXAMINATION FOR LEFT-SIDED PERIPHERAL FACIAL PARALYSIS. DURING THE PROCEDURE, HEALTHCARE PERSONNEL USED A HIGH-PRESSURE INJECTOR PRESSURE SLEEVE TO INJECT CONTRAST MEDIUM. PRIOR TO THE SCAN, ROUTINE INSPECTION OF THE DEVICE REVEALED NO ABNORMALITIES. HOWEVER, DURING INJECTION, THE PRESSURE SLEEVE SUDDENLY RUPTURED, FORCING AN INTERRUPTION OF THE PROCEDURE. THIS RUPTURE REMAINED WITHIN A CONTROLLABLE RANGE: THERE WAS NO SIGNIFICANT FRAGMENT SCATTER, AND NEITHER THE PATIENT NOR THE MEDICAL STAFF SUSTAINED VISIBLE INJURIES. IMMEDIATELY AFTER THE INCIDENT, THE STAFF STOPPED OPERATION, REPLACED THE FAULTY DEVICE WITH A BACKUP UNIT, AND RESUMED THE EXAMINATION. THE DEFECTIVE PRESSURE SLEEVE WAS SUBSEQUENTLY DECOMMISSIONED IN ACCORDANCE WITH REGULATIONS. THIS UNEXPECTED EVENT MAY HAVE RESULTED IN INSUFFICIENT CONTRAST VOLUME, COMPROMISING IMAGE QUALITY AND POTENTIALLY DELAYING DIAGNOSIS. HAD THE RUPTURE NOT BEEN PROMPTLY DETECTED, THE SCATTERING OF SHARP FRAGMENTS COULD HAVE INJURED HEALTHCARE WORKERS OR THE PATIENT, POSING A SERIOUS RISK.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23864621 ↗MalfunctionOct 24, 2024Pressure Problem; Pressure Problem
THIS CASE WAS REPORTED BY A FACILITY IN (B)(6) CHINA ON 25 SEPTEMBER 2024. DETAILS OF THE CASE ARE AS DESCRIBED BELOW: SETTING NAME: (B)(6). PRODUCT NAME: HIGH PRESSURE INJECTOR (OPTIVANTAGE DH) INJURY: SERIOUS INJURY MANIFESTATIONS: DRUG EXTRAVASATION, LOCAL SUBCUTANEOUS EDEMA AT THE INDWELLING NEEDLE LOCATION, AND OBVIOUS PAIN. INSTRUMENT FAILURE: HIGH PRESSURE INJECTOR PRESSURE IS NOT ACCURATE USE PROCESS: ON (B)(6) 2024, THE PATIENT UNDERWENT CTA IN THE ARTERIES OF BOTH LOWER LIMBS. THE RADIOLOGY NURSE FIRST CONDUCTED TWO UNBLOCKAGE TESTS, EACH WITH A VOLUME OF 5ML NORMAL SALINE AND A SPEED OF 4ML/S. THE PATIENT HAD NO LOCAL SWELLING WITH THE RETENTION NEEDLE AND NO SELF-REPORTED PAIN AND DISCOMFORT. NORMAL SCANNING AND INJECTION OF CONTRAST AGENT BEGAN AFTER THE END OF THE EXPERIMENT. WHEN THE SCAN WAS NEARLY HALF OVER, THE MACHINE ISSUED A HIGH PRESSURE ALARM, PROMPTING THE INJECTION TO CONTINUE OR STOP. AT THIS TIME, THE OPERATOR FOUND THAT ALMOST ALL THE INJECTION OF CONTRAST AGENT HAD BEEN COMPLETED, AND THE SCAN WAS COMPLETED AFTER THE INJECTION WAS STOPPED. AFTER THE PATIENT RETURNED TO THE WARD, THE DOCTOR GAVE MAGNESIUM SULFATE WET COMPRESS AND ICE TREATMENT, AND ON (B
Patient problems: Administration Site Reaction; Extravasation; Pain
MAUDE report 20522788 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K063503. One submission often covers many models, so check the product and lot details in each record.
- Z-1694-2008 · Apr 7, 2008 · TerminatedThe OptiVantage DH Injection System is a contrast delivery system and is designed to inject radiopaque contrast media into a patient's vascular system to obtain diagnostic images w
Other Injector, Contrast Medium, Automatic devices
- MEDRAD® Stellant FLEX Syringe Kit FLEXD-150-SPKBayer Medical Care Inc. · Injector, Contrast Medium, Automatic1 recall0 reports
- MEDRAD® Stellant FLEX CT Injection System with Certegra® WorkstationBayer Medical Care Inc. · Injector, Contrast Medium, Automatic19 reports
- MEDRAD® Stellant FLEX CT Injection System with Certegra® Workstation (Upgrade)Bayer Medical Care Inc. · Injector, Contrast Medium, Automatic16 reports
- LF 844005Liebel-Flarsheim Company LLC · Injector, Contrast Medium, Automatic6 reports
- FastLoad™ MR Syringe Pack 017356Bracco Injeneering SA · Injector, Contrast Medium, Automatic4 reports
- EmpowerCTA®+ Injector System 017285Bracco Injeneering SA · Injector, Contrast Medium, Automatic2 deaths3 reports
- UL_INJECT XD 8000Ulrich GmbH & Co. KG · Injector, contrast medium, automatic1 death1 report
- CT Expres™ 3D 651207Bracco Injeneering SA · Injector, Contrast Medium, Automatic1 death1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page