Skip to content

Parker Flex-Tip H-PFNC-70Recalls & reported problems

Salter Labs · Endotracheal Tube, Preformed Nasal, High Volume Low Pressure, Cuffed (PFNC), Parker, 7.0mm · Class 2

All models of Parker Flex-Tip (19)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10749065031709), received between Jun 4, 2025 and Jan 24, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Gas/Air Leak” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Gas/Air Leak2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 24, 2026Gas/Air Leak

    IT WAS REPORTED THAT ON (B)(6) 2025, IMMEDIATELY FOLLOWING NASOTRACHEAL INTUBATION, A LEAK WAS IDENTIFIED. THE PATIENT WAS REINTUBATED USING ORAL INTUBATION. NO DELAY IN THERAPY, HARM, OR INJURY WAS REPORTED AS A RESULT OF THIS EVENT. AIRLIFE RECEIVED A SINGLE REPORT THAT REFERENCED 2 DIFFERENT INCIDENTS, WHICH WERE ASSOCIATED WITH SEPARATE UNITS AND INVOLVED DIFFERENT PATIENTS. THIS IS THE SECOND OF TWO REPORTS REFER TO 3004748541-2026-00022 FOR THE FIRST REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24174890 ↗
  • MalfunctionJun 4, 2025Gas/Air Leak; Gas/Air Leak

    IT WAS REPORTED, IMMEDIATELY AFTER INTUBATING THE SURGICAL PATIENT (WHO WAS IN THE SUPINE POSITION), A LEAK OCCURRED. (NO PRE-INTUBATION LEAK CHECK WAS PERFORMED.) THE DEVICE WAS REMOVED AND A DIFFERENT TRACHEAL TUBE WAS REINTUBATED, AND THERE WAS NO PROBLEM. THE REPORTER VERIFIED THAT THE LOWER PART OF THE CUFF WAS DAMAGED AND CONFIRMED THE LEAK. THERE WAS NO REPORTED INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22146991 ↗

Other Tube, Tracheal (W/Wo Connector) devices

All Tube, Tracheal (W/Wo Connector) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page