Bard® X-Force® Balloon Dilation Catheter 998406Recalls & reported problems
C. R. Bard, Inc. · Bard® X-Force® Balloon Dilation Catheter · Class 2
All models of Bard X-Force Balloon Dilation Catheter (22)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 10801741052658), received between Apr 25, 2017 and May 27, 2025 — classified as 6 malfunctions.
The most frequently reported specific device problem is “Inflation Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Inflation Problem2
- Material Puncture/Hole2
- Use of Device Problem2
- Break1
- Burst Container or Vessel1
- Fluid/Blood Leak1
- Leak/Splash1
- Pressure Problem1
Patient problems
- No Known Impact Or Consequence To Patient4
- No Consequences Or Impact To Patient3
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 27, 2025Material Puncture/Hole; Material Puncture/Hole
IT WAS REPORTED THAT WHEN PRESSURE WAS APPLIED DURING DILATION, THERE WAS A STRANGE SENSATION, SO THEY REMOVED THE DEVICE AND CHECKED IT, AND FOUND THAT STERILE WATER HAD LEAKED FROM THE BALLOON DILATION CATHETER SHAFT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22088956 ↗MalfunctionJan 11, 2023Burst Container or Vessel; Material Puncture/Hole; Burst Container or Vessel; Material Puncture/Hole
IT WAS REPORTED THAT THERE WAS LEAKAGE FROM THE FOLEY CATHETER SHAFT (YELLOW-GREEN PART) DURING INFLATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16137338 ↗MalfunctionDec 19, 2019Use of Device Problem; Use of Device Problem; Pressure Problem
IT WAS REPORTED THAT THE BALLOON INFLATED, THE PRESSURE WAS RAISED, BUT THE PRESSURE ON THE EAGLE INFLATION DEVICE DID NOT GO UP.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9499161 ↗MalfunctionOct 16, 2019Leak/Splash; Use of Device Problem; Use of Device Problem
IT WAS REPORTED THAT A PRESSURE LEAK OCCURRED AT THE INFLATION DEVICE. PER ADDITIONAL INFORMATION FROM THE IBC VIA EMAIL ON (B)(6) 2019, IT WAS UNKNOWN IF THE DILATION BALLOON WAS ABLE TO BE INFLATED OR IF THE USER WAS ABLE TO FEEL THE LEAK FROM THE INFLATION DEVICE.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 9197439 ↗MalfunctionSep 19, 2018Fluid/Blood Leak; Inflation Problem; Inflation Problem
IT WAS REPORTED THAT WHEN THE USER APPLIED PRESSURE, THERE WAS A SMALL SOUND FROM THE METER AND WATER LEAKED.
Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient
MAUDE report 7888691 ↗MalfunctionApr 25, 2017Break; Inflation Problem
IT WAS REPORTED THAT IT WAS DIFFICULT TO INFLATE THE BALLOON AS THE CONTRAST MEDIUM WAS INJECTED INTO THE INFLATION DEVICE. THE BALLOON SHAPE WAS UNUSUAL. THE DEVICE WAS REMOVED FROM THE PATIENT. AFTER FURTHER INSPECTION, IT WAS FOUND THAT THE SHAFT OF THE CATHETER WAS DAMAGED PREVENTING THE BALLOON TO INFLATE IN ITS REGULAR SHAPE.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6519281 ↗
Other DILATOR, CATHETER, URETERAL devices
- Porges Coloplast RBD014Coloplast A/S · DILATOR, CATHETER, URETERAL1 recall0 reports
- Bard® X-Force® Balloon Dilation Catheter 998706C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL38 reports
- Bard® X-Force® Balloon Dilation Catheter 998606C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL27 reports
- Bard® X-Force® Balloon Dilation Catheter 998006C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL25 reports
- Bard® X-Force® Balloon Dilation Catheter 998806C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL23 reports
- Bard® X-Force® Balloon Dilation Catheter 998504C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL16 reports
- Bard® X-Force® Balloon Dilation Catheter 998004C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL15 reports
- Bard® X-Force® Balloon Dilation Catheter 998506C. R. Bard, Inc. · DILATOR, CATHETER, URETERAL15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page