Zenith Flex G48435Recalls & reported problems
Cook Incorporated · Zenith Flex, AAA Endovascular Graft Main Body · Class 3 · Implant
All models of Zenith Flex (54)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 3
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10827002484358), received between May 4, 2016 and Dec 13, 2016 — classified as 3 injuries.
The most frequently reported specific device problem is “Difficult to Remove” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Difficult to Remove2
- Leak/Splash1
Patient problems
- No Code Available2
- Occlusion2
- Blood Loss1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryDec 13, 2016Difficult to Remove; Difficult to Remove
IT WAS REPORTED THAT DURING ENDVASCUAR ANEURYSM REPAIR (EVAR) FOR TREATMENT OF ABDOMINAL AORTIC ANEURYSM (AAA) AFTER RELEASING THE TRIGGER WIRE, THE PHYSICIAN TRIED UNSUCCESSFULLY TO REMOVE THE TOP CAP. HE UNDID THE PIN VICE AND HELD THE GREY INTRODUCER STILL AND TRIED AGAIN TO PUSH THE TOP CAP OFF BUT THE INTRODUCER WIRE KEPT BOWING. AFTER NUMEROUS ATTEMPTS, THE TOP CAP EVENTUALLY CAME OFF, HOWEVER, DUE TO THE PUSHING, THE GRAFT HAD MOVED UP AND COVERED THE RIGHT RENAL ARTERY. AS A RESULT, THE PHYSICIAN HAD TO CANNULATE THE RENAL ARTERY TO PLACE A STENT. THE REST OF THE GRAFT WAS DEPLOYED WITHOUT INCIDENT; HOWEVER, THE PATIENT WAS REPORTED TO HAVE EXPERIENCED IMPAIRED RENAL FLOW DUE TO THE GRAFT COVERING THE RIGHT RENAL ARTERY. NO FURTHER INFORMATION WAS PROVIDED.
Patient problems: No Code Available; Occlusion
MAUDE report 6169026 ↗InjuryJul 13, 2016Leak/Splash; Leak/Splash
IT WAS REPORTED THAT DURING AN ABDOMINAL ANEURYSM REPAIR, THE CHECK-FLO HUB LEAKED THROUGHOUT THE PROCEDURE. THE PATIENT EXPERIENCED BLOOD LOSS (APPROXIMATELY 300 TO 400 LITERS). HOWEVER, THE PROCEDURE WAS COMPLETED WITH THE COMPLAINT DEVICE. THE PATIENT DID NOT REQUIRE ANY ADDITIONAL PROCEDURES NOR EXPERIENCE ANY ADVERSE EFFECTS DUE TO THIS OCCURRENCE.
Patient problems: Blood Loss
MAUDE report 5789655 ↗InjuryMay 4, 2016Difficult to Remove; Difficult to Remove
WHILE PERFORMING A AAA WITH A 36MM X 149MM MAIN BODY GRAFT. THE GRAFT POSITIONED JUST BELOW RIGHT RENAL AND DEPLOYED AS NORMAL UNTIL CONTRALATERAL LIMB OPENED. THE CONTRALATERAL LIMB CANNULATED THEN WENT TO DEPLOY THE SUPRARENAL STENT. THE PROXIMAL TRIGGER WIRE RELEASE WAS UNDONE, BUT UNABLE TO PULL OUT TRIGGER WIRE. AFTER MUCH FORCE THE TRIGGER WIRE PULLED OUT, BUT THIS HAD PULLED THE GRAPH DOWN. THE GRAPH WAS REPOSITIONED TO JUST BELOW THE RIGHT RENAL AGAIN AND THEN TRIED TO DO THE TOP CAP. UNDID THE PIN VICE HELD GREY INTRODUCER STILL AND TRIED TO PUSH THE TOP CAP OFF BUT THE INTRODUCER WIRE KEPT BOWING AND TOP CAP WOULD NOT COME OFF. THE PHYSICIAN TRIED A NUMBER OF TIMES AND EVENTUALLY THE TOP CAP CAME OFF, BUT WITH ALL THE PUSHING IT HAD PUSHED THE GRAFT UP AND COVERED THE RIGHT RENAL. THE PHYSICIAN HAD TO THEN CANNULATE THE RENAL AND PLACE A STENT INTO THE RIGHT RENAL. THE REST OF THE GRAFT WAS DEPLOYED WITHOUT INCIDENCE. THE PATIENT DID NOT REQUIRE AN ADDITIONAL PROCEDURE DUE TO THIS OCCURRENCE, HOWEVER SHE DID REQUIRE A RENAL STENT TO BE PLACED INTO R) RENAL AS THE GRAFT HAD JUMPED FORWARD WITH ALL THE FORCE TO GET THE TOP CAP OFF. ADVERSE EFFECT TO THE PATIENT AS A RESULT
Patient problems: No Code Available; Occlusion
MAUDE report 5631183 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page