Zenith FlexRecalls & reported problems across all models
Cook Incorporated · 54 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 255
- Deaths reported
- 19
- Injuries reported
- 147
- Recalls
- 0
We found 54 models of Zenith Flex by Cook Incorporated in the FDA's device registry (GUDID). Together they are named in 255 adverse event reports in the FDA's MAUDE database, received between Aug 21, 2014 and Jan 16, 2025 — classified as 19 deaths, 147 injuries, 89 malfunctions.
The most frequently reported specific device problem is “Leak/Splash” (65 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported Zenith Flex problems
Device problems
- Leak/Splash65
- Fluid/Blood Leak54
- Adverse Event Without Identified Device or Use Problem15
- Difficult to Remove13
- Difficult to Advance10
- Difficult or Delayed Activation9
- Failure to Advance9
- Material Puncture/Hole8
Patient problems
- No Code Available89
- No Known Impact Or Consequence To Patient35
- No Consequences Or Impact To Patient34
- No Clinical Signs, Symptoms or Conditions27
- Death15
- Blood Loss14
- Clinical Endoleak12
- Rupture11
Zenith Flex models
54 models, most reported first. Each model has its own page with its reports, recalls and device details.
- Zenith Flex G48432SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 deaths23 reports
- Zenith Flex G48407SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT15 reports
- Zenith Flex G48408SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 deaths15 reports
- Zenith Flex G48418SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT15 reports
- Zenith Flex G48428SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT15 reports
- Zenith Flex G48417SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT14 reports
- Zenith Flex G48413SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT13 reports
- Zenith Flex G48402SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT11 reports
- Zenith Flex G48423SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 deaths11 reports
- Zenith Flex G48412SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT9 reports
- Zenith Flex G48419SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT9 reports
- Zenith Flex G48422SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death9 reports
- Zenith Flex G48427SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 deaths9 reports
- Zenith Flex G48433SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 deaths9 reports
- Zenith Flex G48424SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death6 reports
- Zenith Flex G48429SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT5 reports
- Zenith Flex G48414SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT4 reports
- Zenith Flex G48415SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 deaths4 reports
- Zenith Flex G55210SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death4 reports
- Zenith Flex G48403SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 reports
- Zenith Flex G48409SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 reports
- Zenith Flex G48435SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 reports
- Zenith Flex G48451SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT3 reports
- Zenith Flex G32182SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G32184SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G42785SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death2 reports
- Zenith Flex G48425SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G48430SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G48434SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G48449SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G48453SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G48465SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G48478SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G55209SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G55215SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 reports
- Zenith Flex G31174SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death1 report
- Zenith Flex G32179SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G32181SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G32183SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G42783SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G42787SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G42788SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48404SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48450SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48452SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48456SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48457SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48461SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48462SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G48479SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 death1 report
- Zenith Flex G55204SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G55205SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G55214SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
- Zenith Flex G55216SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 report
Recent Zenith Flex adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionJan 16, 2025Difficult to Remove; Difficult to Remove
IN ADDITIONAL INFORMATION RECEIVED ON (B)(6) 2025, IT WAS REPORTED THAT THE PATIENT HAD SOME TORTUOSITY AND ATHEROMA/CALCIFICATION. THE RIGHT COMMON ILIAC ARTERY (CIA) STENT WAS IN-SITU PRIOR TO THE CASE. THE PROXIMAL TOP STENT TRIGGER WIRE WAS RELEASED PRIOR TO ADVANCEMENT OF THE TOP CAP. NO DIFFICULTY WAS EXPERIENCED WITH TOP CAP REMOVAL. IT WAS CONFIRMED THAT THE DISTAL IPSILATERAL LIMB TRIGGER WIRE WAS RELEASED PRIOR TO ADVANCEMENT OF THE TOP CAP. THE IFU WAS FOLLOWED, AND ALL TRIGGER WIRES WERE REMOVED. NO TENSION WAS FELT. ONLY ONCE THE DILATOR TIP WAS COMING DOWN INTO THE DISTAL AORTA/ILIACS WAS IT NOTICED THAT THE CANNULA AND DILATOR WERE SEPARATING. THE PIN VISE WAS CHECKED AGAIN TO MAKE SURE THAT IT WAS SECURE, AND IT DID NOT APPEAR TO BE LOOSE. WHEN TRYING TO REMOVE THE SYSTEM THROUGH THE SHEATH, THE SEPARATION WAS CONTINUED AND COULD NOT BE REMOVED. A SHORT 18F SHEATH WAS PREPARED AND A SHEATH EXCHANGE WAS MADE. THE DEVICE WAS REMOVED COMPLETELY, WITH THE SHEATH AND DILATOR/CANNULA STILL INSIDE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21170735 ↗MalfunctionDec 30, 2024Fluid/Blood Leak; Fluid/Blood Leak
ADDITIONAL INFORMATION WAS PROVIDED ON 07JAN2025. THE DELIVERY SYSTEM OF THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY WAS FLUSHED WITH 40 CC¿S OF HEPARINIZED SALINE PRIOR TO ORIENTING THE CONTRALATERAL GATE CHECK MARK UNDER FLUOROSCOPY. THE CUSTOMER AND COOK SALES REPRESENTATIVE BELIEVED THAT IT WAS THE VALVE THAT LEAKED. IT WAS REPORTED THAT IT WAS POSSIBLE THAT THE VALVE MAY HAVE BEEN DAMAGED WHEN REMOVING THE PEEL AWAY SHEATH DURING GRAFT PREPARATION. THE SCRUB TECHNICIAN PEELED THE PEEL AWAY SHEATH APART UNTIL IT RIPPED. TYPICALLY, THE TECHNICIAN STOPS ONCE THE PEEL AWAY SHEATH REACHES THE VALVE. THEN, THE TECHNICIAN STABILIZES THE DEVICE AND SLIDES THE REMAINING PEEL AWAY SHEATH OUT OF THE VALVE BEFORE COMPLETELY REMOVING IT. BEFORE THE CATHETER COULD BE INSERTED TO MEASURE FOR IPSILATERAL LIMB, THE VALVE WAS NOTICED TO BE LEAKING AFTER REMOVING THE DILATOR. AT THIS POINT, THE VALVE WAS CLOSED AND IT STILL CONTINUED TO LEAK. THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY DELIVERY SYSTEM WAS REMOVED AND WAS REPLACED WITH A COMPETITOR'S SHEATH WITH THE SAME DIAMETER WHICH WAS READILY AVAILABLE IN THE OPERATING ROOM. THE PATIENT DID NOT REQUIRE A TRANS
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 21035172 ↗MalfunctionSep 13, 2024Fluid/Blood Leak; Fluid/Blood Leak
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: Clinical Endoleak
MAUDE report 20214934 ↗MalfunctionAug 23, 2024Device Damaged by Another Device; Device Damaged by Another Device
IT WAS REPORTED THAT A 76 YEAR OLD FEMALE REQUIRED A ZENITH FLEX WITH Z-TRAK AAA ENDOVASCULAR GRAFT MAIN BODY EXTENSION (ESBE-24-39-ZT) FOR A TYPE 1A ENDOLEAK FOLLOWING A PREVIOUS ABDOMINAL ENDOVASCULAR AORTIC REPAIR (EVAR). AS THE PATIENT HAD A NARROW DISTAL AORTA, ¿KISSING¿ STENTS FROM ANOTHER MANUFACTURER, MEASURING 39MM IN LENGTH AND 10MM IN DIAMETER, HAD BEEN INSERTED INTO THE CONTRALATERAL AND IPSILATERAL LIMBS AT THE TIME OF THE INDEX EVAR. WHEN THE ESBE-24-39-ZT WAS INSERTED VIA THE IPSILATERAL LIMB, IT DISLODGED THE KISSING STENT THAT WAS ALREADY IN PLACE AND CAUSED IT TO MIGRATE UP INTO THE MAIN BODY. THE PATIENT WILL REQUIRED AN ADDITIONAL PROCEDURE, BUT THE DETAILS ARE PENDING. ADDITIONAL INFORMATION REGARDING THE EVENT AND PATIENT OUTCOME HAS BEEN REQUESTED BUT IS CURRENTLY UNAVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20052174 ↗MalfunctionMay 10, 2024Difficult to Advance; Difficult to Advance
IT WAS REPORTED TO COOK ON 13MAY2024 THAT THE DIFFICULT ADVANCEMENT OVER THE LUNDERQUIST WIRE HAPPENED OUTSIDE THE PATIENT. THE PROCEDURE WAS COMPLETED OVER THE AMPLATZ WIRE IN THE SAME WAY IT WOULD HAVE OVER A LUNDERQUIST WIRE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19287934 ↗InjuryApr 2, 2024Fluid/Blood Leak; Fluid/Blood Leak
ADDITIONAL INFORMATION WAS RECEIVED INDICATING THAT THERE WAS NO DIFFICULTY IN ADVANCING THE DEVICE OR RESISTANCE OF ANY KIND REPORTED.
Patient problems: Clinical Endoleak
MAUDE report 19028631 ↗MalfunctionMar 14, 2024Difficult to Remove; Difficult to Remove
ADDITIONAL INFORMATION WAS PROVIDED ON 18MAR2024 INDICATING THAT THE PATIENT'S ILIAC ARTERIES WERE NOT TORTUOUS. AS REPORTED, THE PATIENT DID NOT HAVE PRE-EXISTING CONDITIONS OR COMORBIDITIES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18904787 ↗InjuryJan 9, 2024Material Separation; Activation Failure; Material Separation; Activation Failure
NO ADDITIONAL INFORMATION REGARDING THE PATIENT AND/OR EVENT HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: Insufficient Information
MAUDE report 18477506 ↗MalfunctionDec 27, 2023Fracture; Fracture
IT WAS REPORTED THAT THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY FRACTURED. THE PATIENT HAD THE GRAFT PLACED DURING AN ENDOVASCULAR ANEURYSM REPAIR (EVAR) IN (B)(6) 2013. THE ULTRASOUND AND X-RAY IMAGES WERE NORMAL, AND NO ISSUES WERE NOTED DURING THE FOLLOW-UP OF 2022. DURING THE 2023 FOLLOW-UP, THERE WAS NO INCREASE IN THE ANEURYSM SAC SIZE PER ULTRASOUND IMAGING. HOWEVER, THE X-RAY IMAGING SHOWED THE SUPRARENAL FIXATION AND THE SUPRARENAL RING HAD BOTH FRACTURED OFF OF THE GRAFT. UPON THIS FINDING, A COMPUTED TOMOGRAPHY (CT) SCAN HAS BEEN REQUESTED. THE POSSIBLE OPTIONS ARE UNDER CONSIDERATION TO ADDRESS THE ISSUE: FENESTRATED CUFF IF CLINICALLY SUITABLE, BRACE TOP END WITH BARE METAL STENT IF NOT TOO FIT, OR NO INTERVENTION IF THE PATIENT IS UNFIT. A DECISION WILL BE MADE ON NEXT STEP OF TREATMENT AFTER THE PHYSICIAN DISCUSSES THESE OPTIONS WITH THE PATIENT. ADDITIONAL INFORMATION REGARDING THE EVENT AND PATIENT OUTCOME HAS BEEN REQUESTED BUT IS CURRENTLY UNAVAILABLE. THIS REPORT CAPTURES THE SUPRARENAL RING FRACTURE OFF OF THE GRAFT. ANOTHER REPORT WITH THE SAME PATIENT IDENTIFIER (B)(6) CAPTURES THE SUPRARENAL FIXATION FRACTURE OFF OF THE GRAFT.
Patient problems: Insufficient Information
MAUDE report 18401437 ↗MalfunctionDec 27, 2023Fracture; Detachment of Device or Device Component; Fracture; Detachment of Device or Device Component
NO ADDITIONAL INFORMATION REGARDING PATIENT AND/OR EVENT DETAILS HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: Insufficient Information
MAUDE report 18401162 ↗DeathDec 6, 2023Obstruction of Flow; Malposition of Device; Obstruction of Flow; Malposition of Device
ADDITIONAL INFORMATION WAS PROVIDED ON 05DEC2023. A COMPLETE MEDICAL RECORD WAS PROVIDED FOR REVIEW, THIS REPORT CONTAINS SPECIFICS RELATED TO THE PROCEDURE AND SUBSEQUENT EVENTS CONCERNING THE COOK GRAFT. PROCEDURE DATE: (B)(6) 2021. THE PATIENT WAS SEEN IN THE HOLDING ROOM. THE RISKS, BENEFITS, COMPLICATIONS, TREATMENT OPTIONS, AND EXPECTED OUTCOMES WERE DISCUSSED WITH THE PATIENT. THE POSSIBILITIES OF REACTION TO MEDICATION, PULMONARY ASPIRATION, PERFORATION OF VISCUS, BLEEDING, RECURRENT INFECTION, THE NEED FOR ADDITIONAL PROCEDURES, FAILURE TO DIAGNOSE A CONDITION, AND CREATING A COMPLICATION REQUIRING TRANSFUSION OR OPERATION WERE DISCUSSED WITH THE PATIENT. THE PATIENT CONCURRED WITH THE PROPOSED PLAN, GIVING INFORMED CONSENT. THE SITE OF SURGERY PROPERLY NOTED/MARKED. THE PATIENT WAS TAKEN TO THE OPERATING ROOM, IDENTIFIED AND THE PROCEDURE VERIFIED AS AAA REPAIR. A TIME OUT WAS HELD AND THE ABOVE INFORMATION CONFIRMED. GENERAL ENDOTRACHEAL ANESTHESIA WAS INITIATED AFTER PLACEMENT OF APPROPRIATE MONITORING LINES. AN ARTERIAL LINE WAS PLACED. ARMS WERE TUCKED AT THE SIDES. ALL PRESSURE POINTS WERE WELL PADDED. INTRAVENOUS ANTIBIOTICS WERE CONFIRMED. THE PATIENT WAS PREPARED
Patient problems: Cardiac Arrest; Cardiomyopathy; Myocardial Infarction; Obstruction/Occlusion; Renal Failure; Thrombosis/Thrombus
MAUDE report 18275905 ↗MalfunctionNov 16, 2023Difficult to Remove; Difficult to Advance; Difficult to Remove; Difficult to Advance
ADDITIONAL INFORMATION WAS PROVIDED ON 22NOV2023. THE PHYSICIAN INDICATED THAT THEY ARE GOING TO GET A ONE MONTH SCAN BEFORE PROCEEDING WITH TREATMENT FOR THE POTENTIAL ENDOLEAK. THE PHYSICIAN INDICATED POTENTIAL ENDOLEAK MIGHT STILL BE A TYPE 2 ENDOLEAK.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18149072 ↗InjurySep 15, 2023Difficult to Remove; Obstruction of Flow; Difficult to Advance; Adverse Event Without Identified Device or Use Problem; Migration; Difficult to Remove; Obstruction of Flow; Difficult to Advance; Adverse Event Without Identified Device or Use Problem; Migration
ADDITIONAL INFORMATION WAS PROVIDED ON 18SEP2023. AFTER PLACING THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY (TFFB-26-96-ZT) AND THE CONTRALATERAL ZENITH FLEX WITH SPIRAL-Z TECHNOLOGY AAA ENDOVASCULAR GRAFT ILIAC LEG (RPN: ZSLE-16-90-ZT, LOT 15554354) THE PHYSICIAN ATTEMPTED TO DOCK THE TOP CAP OF THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY (TFFB-26-96-ZT). HOWEVER, THE PHYSICIAN CAUGHT AN APEX OF THE BARE SUPRA RENAL STENT BETWEEN THE DILATOR AND THE SHEATH OF THE DELIVERY SYSTEM WHILE ATTEMPTING TO DOCK THE TOP CAP. THE PHYSICIAN WAS UNAWARE OF THE STENT BEING CAUGHT AND WAS UNSUCCESSFUL IN HIS ATTEMPT TO REMOVE THE DELIVERY SYSTEM. THE PHYSICIAN THEN ATTEMPTED TO ADVANCE THE DELIVERY SYSTEM. THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY (TFFB-26-96-ZT) MIGRATED UPWARD AND CAUSED OCCLUSION OF THE RENAL ARTERIES. THE CONTRALATERAL ZENITH FLEX WITH SPIRAL-Z TECHNOLOGY AAA ENDOVASCULAR GRAFT ILIAC LEG (RPN: ZSLE-16-90-ZT) SEPARATED FROM THE MAIN BODY GRAFT. THE PHYSICIAN HAD TO CONVERT THE PATIENT TO AN OPEN REPAIR. A PORTION OF THE MAIN BODY GRAFT REMAINED IN THE PATIENT DURING THE OPEN REPAIR.
Patient problems: Insufficient Information; Obstruction/Occlusion
MAUDE report 17757051 ↗MalfunctionSep 12, 2023Fluid/Blood Leak; Fluid/Blood Leak
NO ADDITIONAL INFORMATION REGARDING PATIENT AND/OR EVENT DETAILS HAS BEEN RECEIVED SINCE THE PREVIOUS MEDWATCH REPORT WAS SENT.
Patient problems: Clinical Endoleak
MAUDE report 17730038 ↗InjuryAug 31, 2023Fluid/Blood Leak; Fluid/Blood Leak
IN 2014 A PATIENT UNDERWENT AN ENDOVASCULAR AORTIC REPAIR (EVAR) PROCEDURE WHERE THE FOLLOWING COOK GRAFTS WERE PLACED: ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY (RPN: TFFB-36-95-ZT , LOT NUMBER 4053084); ZENITH BRANCH ENDOVASCULAR GRAFT ILIAC BIFURCATION (RPN: ZBIS-10-45-41, LOT NUMBER A937127) ZENITH FLEX WITH SPIRAL-Z TECHNOLOGY AAA ENDOVASCULAR GRAFT ILIAC LEG (RPN: ZSLE-16-56-ZT, LOT NUMBER 4715582); ZENITH FLEX WITH SPIRAL-Z TECHNOLOGY AAA ENDOVASCULAR GRAFT ILIAC LEG (RPN: ZSLE-20-56-ZT, LOT NUMBER 4792180). IN 2020 A REINTERVENTION PROCEDURE WAS COMPLETED. THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED MAIN BODY (RPN: TFFB-36-95-ZT LOT NUMBER 4053084) LOST WALL APPOSITION PROXIMALLY CREATING A TYPE 1A ENDOLEAK. A FENESTRATED TUBE GRAFT (MANUFACTURER UNKNOWN) WAS PLACED DURING THE SECONDARY PROCEDURE. A COMPUTED TOMOGRAPHY SCAN WAS COMPLETED ON (B)(6) 2023 AND AN ENDOLEAK WAS NOTED AND THOUGHT TO BE A TYPE 3B ENDOLEAK. AN ULTRASOUND BUBBLE TEST WAS ALSO PERFORMED AFTER THE REINTERVENTION PROCEDURE IN 2020. ON (B)(6) 2023 A REINTERVENTION PROCEDURE WAS COMPLETED WITH THE INTENTION TO RELINE THE DISTAL END OF THE ZENITH FLEX AAA ENDOVASCULAR GRAFT BIFURCATED M
Patient problems: Clinical Endoleak
MAUDE report 17662370 ↗
Other Cook Incorporated products
All Cook Incorporated devices →Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page