- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10827002484570), received between May 10, 2018 and May 10, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Leak/Splash” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Leak/Splash1
- Torn Material1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 10, 2018Leak/Splash; Torn Material; Leak/Splash; Torn Material
IT WAS REPORTED THAT DURING AN EXPLANT PROCEDURE A TYPE III ENDOLEAK OBSERVED AND TREATED. THE (B)(6) MALE PATIENT RECEIVED AN ENDOVASCULAR GRAFT ON (B)(6) 2011 FOR AN ANEURYSM MEASURING ~5 CM. A MAIN BODY AND TWO LIMBS WERE IMPLANTED. OVER TIME THE ANEURYSM SAC CONTINUED TO FILL AND THE MOST RECENT SCAN SHOWED THE SAC HAD GROWN TO APPROXIMATELY 9 CM. IT LOOKED LIKE A TYPE 2 ENDOLEAK WITH A PATENT INFERIOR MESENTERIC ARTERY OR PATENT LUMBAR ARTERIES. THE PATIENT WAS NOT SYMPTOMATIC. ON (B)(6) 2018, THE PATIENT UNDERWENT OPEN SURGERY TO EXPLANT THE ENDOGRAFT DURING WHICH, THE SURGEON NOTICED A GRAFT TEAR IN THE LEFT COMMON ILIAC. A TYPE 3 ENDOLEAK WAS CAUSING THE SAC TO FILL. THE SURGEONS CUT THE MAIN BODY GRAFT UNDER THE FIRST COVERED STENT, LEAVING THE SUPRARENAL STENT AND THE FIRST COVERED STENT OF THE ENDOGRAFT IN THE AORTA. THE SURGEON SUTURED A NEW GRAFT TO THE REMAINING FABRIC OF THE COOK ENDOGRAFT.
Patient problems: No Code Available
MAUDE report 7503872 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page