Zenith Flex G48465Recalls & reported problems
Cook Incorporated · Zenith Flex, AAA Endovascular Graft Iliac Leg · Class 3 · Implant
All models of Zenith Flex (54)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10827002484655), received between Apr 29, 2020 and Jan 13, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Activation Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Activation Problem1
- Failure to Advance1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 13, 2022Failure to Advance; Failure to Advance
IT WAS REPORTED THAT A GAP WAS FOUND BETWEEN THE ZENITH FLEX AAA ENDOVASCULAR GRAFT ILIAC LEG TIP AND THE SHEATH, LEADING TO A FAILED DEPLOYMENT OF THE GRAFT. DURING AN ENDOVASCULAR EXCLUSION OF AN ABDOMINAL AORTIC ANEURYSM, A GAP WAS NOTED BETWEEN THE GRAFT TIP AND THE SHEATH AS THE OPERATOR OPENED THE DEVICE. AN ATTEMPT TO CONTINUE THE PROCEDURE WAS MADE, HOWEVER RESISTANCE CAUSED BY THE GAP PREVENTED THE GRAFT FROM ADVANCING TO THE TARGET SITE. SEVERAL ATTEMPTS WERE MADE, BUT ALL FAILED. THE DEVICE WAS WITHDRAWN AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A NEW LIKE DEVICE. IT WAS CONFIRMED BY THE CUSTOMER THAT THE COMPLAINT GRAFT WAS NOT UNSHEATHED DURING THE PROCEDURE. NO HARM TO THE PATIENT HAS BEEN REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 13251011 ↗MalfunctionApr 29, 2020Activation Problem; Activation Problem
ON (B)(6) 2020, THE SALES REPRESENTATIVE WHO WAS PRESENT AT THE PROCEDURE CONFIRMED THAT THE EVENT OCCURRED DURING THE PREPARATION STAGE. THE OPERATOR TRIED TO PULL OUT THE SHIPPING STYLET AND FOUND THE STYLET WAS UNABLE TO BE PULLED OUT, AND THE SHEATH WAS ALSO TWISTED DUE TO THE FORCE. THE PROCEDURE WAS FINALLY COMPLETED WITH ANOTHER NEW DEVICE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10010953 ↗
Other SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT devices
- Endurant® IIs ESBF2814C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls34 deaths254 reports
- Endurant® IIs ESBF3214C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls19 deaths173 reports
- Endurant® IIs ESBF3614C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT1 recall37 deaths214 reports
- Endurant® IIs ESBF2514C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls18 deaths136 reports
- Endurant® IIs ESBF2314C103EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls9 deaths60 reports
- RelayPro Thoracic Stent-Graft System 28-N4-34-154-34UBolton Medical Inc. · System, Endovascular Graft, Aortic Aneurysm Treatment3 recalls7 reports
- Vela Proximal Endograft System A34-34/C100-O20 VEndologix LLC · System, Endovascular Graft, Aortic Aneurysm Treatment3 deaths152 reports
- Endurant® II ETCF2828C49EMedtronic, Inc. · SYSTEM, ENDOVASCULAR GRAFT, AORTIC ANEURYSM TREATMENT2 recalls7 deaths44 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page