AtriClip® FLEX-Mini™ LAA Exclusion System ACHM50Recalls & reported problems
Atricure, Inc. · LAA Exclusion System, ACHM50 · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10840143911804), received between May 14, 2026 and May 14, 2026 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Hemorrhage/Blood Loss/Bleeding1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMay 14, 2026Adverse Event Without Identified Device or Use Problem
A PATIENT UNDERWENT CORONARY ARTERY BYPASS GRAFT (CABG) AND AORTIC VALVE REPLACEMENT/REPAIR (AVR) VIA MEDIAN STERNOTOMY WITH CONCOMITANT TAMPA 2 SURGICAL ABLATION LESION SET AND LEFT ATRIAL APPENDAGE EXCLUSION (LAAE). AN INCISION WAS MADE IN THE LEFT ATRIAL APPENDAGE (LAA) FOR ACCESS TO PERFORM THE TAMPA 2 LESION SET, WHICH WAS COMPLETED AS PLANNED. AN ACHM50 ATRICLIP DEVICE WAS DEPLOYED AFTER THE CONCOMITANT SURGICAL ABLATION PROCEDURE. POSTOPERATIVELY, THE PATIENT WAS TRANSFERRED TO THE OPEN-HEART RECOVERY UNIT BUT WAS SUBSEQUENTLY RETURNED TO THE OPERATING ROOM DUE TO BLEEDING. UPON EVALUATION, THE SURGEON IDENTIFIED A SMALL LEAK AT THE LAA OSTIUM, NEAR THE SITE OF THE ACCESS INCISION. THE LAA WAS OVERSEWN, AND THE PATIENT RECOVERED WITHOUT FURTHER REPORTED COMPLICATIONS.
Patient problems: Hemorrhage/Blood Loss/Bleeding
MAUDE report 25172950 ↗
Other Left Atrial Appendage Clip, Implantable devices
- Penditure™ LAAC45Medtronic, Inc. · Left atrial appendage clip, implantable7 reports
- Penditure™ LAAC50Medtronic, Inc. · Left atrial appendage clip, implantable1 death7 reports
- Penditure™ LAAC40Medtronic, Inc. · Left atrial appendage clip, implantable6 reports
- Penditure™ LAAC35Medtronic, Inc. · Left atrial appendage clip, implantable2 reports
- AtriClip PROV® LAA Exclusion System PROV50Atricure, Inc. · Left Atrial Appendage Clip, Implantable1 death1 report
- AtriClip PRO2® Gillinov-Cosgrove™ LAA Exclusion System PRO235Atricure, Inc. · Left Atrial Appendage Clip, Implantable1 report
- AtriClip® FLEX-Mini™ LAA Exclusion System ACHM40Atricure, Inc. · Left Atrial Appendage Clip, Implantable1 report
- AtriClip® FlexV® LAA Exclusion System ACHV45Atricure, Inc. · Left Atrial Appendage Clip, Implantable1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page