ONCONTROL IPN919016Recalls & reported problems
Teleflex Incorporated · OnControl® Bone Marrow Biopsy System Tray, 152mm · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10841156108472), received between Feb 22, 2023 and Feb 22, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- Device Embedded In Tissue or Plaque1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 22, 2023Material Fragmentation; Material Fragmentation
IT WAS REPORTED THAT: DURING BONE MARROW PROCEDURE, THE ACCESS NEEDLE BROKE OFF AT THE HUB. AFTER THE DEVICE BROKE OFF AT THE HUB A HEMOSTAT WAS USED TO TRY TO REMOVE THE NEEDLE THAT WAS IN ILIAC. NEEDLE BROKE AGAIN MID SHAFT UNDER THE SKIN. PATIENT WAS SENT TO SURGERY TO REMOVE THE REMAINDER OF THE NEEDLE. ADDITIONAL INFORMATION ON 13FEB2023: DURING A BONE MARROW PROCEDURE ON THE (B)(6) 2023 THE CANNULA BROKE OFF AT THE LEVEL OF THE DEPTH GAUGE. AT THAT POINT THE CANNULA WAS STICKING OUT OF PATIENT. THE PHYSICIAN ATTEMPTED TO REMOVE THE CANNULA THAT WAS STUCK IN BONE WITH A HEMOSTAT. THE CANNULA BROKE AGAIN LEAVING THE REST IN THE BODY. THE PATIENT WAS THEN SENT TO SURGERY WHERE THEY SUCCESSFULLY REMOVED THE CANNULA IN ITS ENTIRETY. THE PATIENT WAS REPORTED AS FINE POST THE INCIDENT.
Patient problems: Device Embedded In Tissue or Plaque
MAUDE report 16416291 ↗
Other INSTRUMENT, BIOPSY devices
- MAX-CORE MC1616Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall4,258 reports
- ENCOR® ECP017GSenorx, Inc. · INSTRUMENT, BIOPSY1 recall4,186 reports
- MAX-CORE MC1820Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall2,404 reports
- MAX-CORE MC1816Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall1 death848 reports
- MAX-CORE MC1410Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall399 reports
- MAX-CORE MC1610Bard Peripheral Vascular, Inc. · INSTRUMENT, BIOPSY1 recall394 reports
- ENCOR® ECP0110GVSenorx, Inc. · INSTRUMENT, BIOPSY392 reports
- ENCOR® ECP0110GSenorx, Inc. · INSTRUMENT, BIOPSY390 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page