Skip to content

Myo/Wire 024-311Recalls & reported problems

A & E Medical Corporation · Temp Pacing Wire · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10841291100263), received between Jul 7, 2023 and Jul 7, 2023 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Fracture” (4 reports).

3 other recalls cover devices cleared under the same FDA submission (K803086); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Most reported problems

Device problems

  • Fracture4
  • Material Frayed4
  • Detachment of Device or Device Component3
  • Connection Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Tachycardia1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 7, 2023Fracture; Material Frayed; Connection Problem; Detachment of Device or Device Component; Fracture; Material Frayed; Connection Problem; Detachment of Device or Device Component

    NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions; Tachycardia

    MAUDE report 17278501 ↗
  • InjuryJul 7, 2023Fracture; Material Frayed; Detachment of Device or Device Component; Fracture; Material Frayed; Detachment of Device or Device Component

    NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17278404 ↗
  • MalfunctionJul 7, 2023Fracture; Material Frayed; Fracture; Material Frayed

    NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17278263 ↗
  • MalfunctionJul 7, 2023Fracture; Material Frayed; Detachment of Device or Device Component; Fracture; Material Frayed; Detachment of Device or Device Component

    NO FURTHER EVENT INFORMATION IS AVAILABLE AT THE TIME OF THIS REPORT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17278256 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K803086. One submission often covers many models, so check the product and lot details in each record.

  • Z-2993-2024 · Apr 8, 2024 · Open, Classified
    Medline Convenience kits labeled as: 1) CATH LAB SPECIAL PROCEDURE, Pack Number 00-RDF036O; 2) CATH LAB SPECIAL PROCEDURE, Pack Number 00-RDF036OH; 3) CATH ACCESSORY PACK, Pack
  • Z-2991-2024 · Apr 8, 2024 · Open, Classified
    Medline Convenience kits labeled as: CARDIAC PACING PACK, Pack Number DYNJ41223
  • Z-2098-2019 · Jun 21, 2019 · Terminated
    A&E Medical Corp. Ultra-Flex MYO/Wire Ultra-Flex Monopolar Pacing Wire Looped Electrode (M-21 SERIES)- Temporary Pacing Electrode as follows: 021-001 MYO/Wire Ultra-Flex Monopolar

Other Electrode, Pacemaker, Temporary devices

All Electrode, Pacemaker, Temporary devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page