RD SET 4473Recalls & reported problems

Masimo Corporation · Neonatal/Adult Pulse Oximeter Adhesive Sensor · Class 2

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10843997013229), received between Feb 19, 2026 and Sep 28, 2026 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Low Readings” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 2 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 1 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Low Readings3
  • Failure to Sense1
  • Sensing Intermittently1
  • Unable to Obtain Readings1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 28, 2026Low Readings

    The customer reported that a baby undergoing phototherapy, with the SpO2 sensor shielded from light by a strip. The sensor had been reading accurately for the past two days. The baby has had stable vital signs since birth. Suddenly, the SpO2 drops to 30%. After removing the baby from phototherapy and waking him up, he showed no clinical signs of desaturation. After replacing the oxygen saturation sensor, the SpO2 level returned to 96%. There was no patient impact or consequence reported.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50910647 ↗
  • MalfunctionMar 30, 2026Unable to Obtain Readings; Sensing Intermittently; Failure to Sense

    THE CUSTOMER REPORTED THAT THE SENSOR STOP(S) FUNCTIONING (EMITTER LIGHT SWITCH OFF), NO ALARM ON "MINDRAY MONITOR". DISCONNECT AND RECONNECT THE SENSOR DIDN'T CHANGE THE SITUATION. THERE WAS NO PATIENT IMPACT OR CONSEQUENCE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24710248 ↗
  • MalfunctionMar 4, 2026Low Readings

    THE CUSTOMER REPORTED THAT "THE SPO2 VALUE MEASURED BY MINDRAY/MASIMO WAS "FALSELY" LOW COMPARED WITH FORMER PHILIPS/FAST MONITOR WITH NELLCOR SENSOR AND ABG SAO2: MINDRAY/MASIMO - LEFT HAND: SPO2 = 86; PHILIPS MP2/FAST - FOOT: SPO2 = 94; ABG: SAO2 = 92.4; 4 - 6 PTS DIFFERENCE". THERE WAS NO PATIENT IMPACT OR CONSEQUENCE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24506685 ↗
  • MalfunctionFeb 19, 2026Low Readings

    THE CUSTOMER REPORTED THAT "THE SPO2 VALUES MEASURED BY THE MONITOR ARE 'FALSELY' LOW COMPARED WITH THE CLINICAL SIGNS AND BLOOD GAS RESULTS, AND WHEN COMPARED WITH OTHER PULSE OXIMETERS". "THE DELTA OBSERVED COULD VARY FROM 2 TO 15 PTS VERSUS OTHER PULSE OXIMETERS". "THIS HAS LED TO UNNECESSARY OXYGEN TREATMENT" WITH NO PATIENT IMPACT REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24397462 ↗

Other Oximeter devices

All Oximeter devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.