CONMED 00509223000Recalls & reported problems
Conmed Corporation · ROUND BUR, LONG, CARBIDE, 5 MM · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10845854001189), received between Feb 28, 2023 and Feb 28, 2023 — classified as 1 injury.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 28, 2023Material Fragmentation; Material Fragmentation
THE DISTRIBUTOR REPORTED ON BEHALF OF THE CUSTOMER THAT THE 00509223000, 5MM ROUND BUR, LONG, CARBIDE, 5EA, WAS BEING USED DURING AN UNKNOWN PROCEDURE ON THE DATE OF 07FEB23, WHEN IT WAS REPORTED, ¿OUR CUSTOMER USED THIS BUR WITH THE SURGAIRTOME TWO BUT DID NOT USE THE BUR GUARD. WHEN USED IN THAT STATE, THE SPHERICAL CUT PORTION AT THE TIP CAME OFF AND REMAINED IN THE BONE. ALSO, THE SHAFT BROKE IN TWO.¿. AFTER FURTHER ASSESSMENT, IT WAS REPORTED THE FRAGMENTATION STILL REMAINS IN THE PATIENT¿S BONE. THE PROCEDURE WAS COMPLETED WITH AN ALTERNATE BACKUP BUR. IT WAS REPORTED THERE WAS NO PATIENT OR USER IMPACT, MEDICAL OR SURGICAL INTERVENTION. IT IS UNKNOWN IF THE PATIENT REQUIRED EXTENDED HOSPITALIZATION. THE PATIENT IS REPORTED TO BE UNDER OBSERVATION. THIS REPORT IS BEING RAISED ON THE BASIS OF INJURY DUE TO FRAGMENTATION REMAINING IN THE PATIENT¿S BODY.
Patient problems: Foreign Body In Patient
MAUDE report 16452640 ↗
Other BUR, SURGICAL, GENERAL & PLASTIC SURGERY devices
- NA 5820066012Stryker Corporation · Bur, Surgical, General & Plastic Surgery1 recall4 reports
- NA 310.25SSynthes GmbH · BUR, SURGICAL, GENERAL & PLASTIC SURGERY1 recall0 reports
- Arthrex® AR-8400OBEArthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY48 reports
- NA 310.21Synthes GmbH · BUR, SURGICAL, GENERAL & PLASTIC SURGERY29 reports
- NA 351.27Synthes GmbH · BUR, SURGICAL, GENERAL & PLASTIC SURGERY28 reports
- Arthrex® AR-8500OBEArthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY27 reports
- Arthrex® AR-8500FOTArthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY17 reports
- Arthrex® AR-8150PX-45Arthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY15 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page