CONMED 00509223200Recalls & reported problems
Conmed Corporation · ROUND BUR, LONG, CARBIDE, 6.5 MM · Class 1
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10845854002940), received between May 22, 2018 and May 22, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment Of Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Detachment Of Device Component1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 22, 2018Detachment Of Device Component; Detachment Of Device Component
THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER THAT THE 00509223200, 6.5 MM ROUND BUR, LONG, CARBIDE, 5EA, WAS BROKEN DURING USE BY A SURGEON ON (B)(6) 2018 WHILE CONDUCTING A HIP REPLACEMENT PROCEDURE. FRAGMENTS OF THE DEVICE FELL INTO THE SURGICAL SITE; HOWEVER, ALL WERE RETRIEVED USING TWEEZER/GRASPER. THERE WAS A REPORTED 15-MINUTE DELAY FOR AN X-RAY TO ASSURE RETRIEVAL OF ALL FRAGMENTS AND THEN THE PROCEDURE WAS COMPLETED SUCCESSFULLY. THERE WAS NO EXTENDED HOSPITAL STAY DUE TO THIS EVENT. THE STATUS OF THE PATIENT IS REPORTED AS NORMAL. IT WAS REPORTED THAT THERE WAS NO INJURY TO PATIENT OR USER. THIS REPORT IS BEING RAISED ON THE BASIS OF DEVICE MALFUNCTION WITH POTENTIAL OF INJURY UPON REOCCURRENCE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7533476 ↗
Other BUR, SURGICAL, GENERAL & PLASTIC SURGERY devices
- NA 5820066012Stryker Corporation · Bur, Surgical, General & Plastic Surgery1 recall4 reports
- NA 310.25SSynthes GmbH · BUR, SURGICAL, GENERAL & PLASTIC SURGERY1 recall0 reports
- Arthrex® AR-8400OBEArthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY48 reports
- NA 310.21Synthes GmbH · BUR, SURGICAL, GENERAL & PLASTIC SURGERY29 reports
- NA 351.27Synthes GmbH · BUR, SURGICAL, GENERAL & PLASTIC SURGERY28 reports
- Arthrex® AR-8500OBEArthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY27 reports
- Arthrex® AR-8500FOTArthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY17 reports
- Arthrex® AR-8150PX-45Arthrex, Inc. · BUR, SURGICAL, GENERAL & PLASTIC SURGERY15 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.