Skip to content

MClass TN190-127-05Recalls & reported problems

Conmed Corporation · MCLASS OSCILLATING SAW BLADE 19 X 1.27 (0.050") X 105 MM · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 10845854021224), received between Sep 18, 2023 and Aug 7, 2025 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Material Fragmentation” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 1 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Fragmentation4
  • Material Separation2
  • Fracture1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 7, 2025Fracture; Fracture

    A DISTRIBUTOR REPORTED ON BEHALF OF A CUSTOMER THAT THE TN190-127-05, MCLASS OSCILLATING SAW BLADE 19 X 1.27 (0.050") X 105 MM DEVICE WAS USED IN A TKA PROCEDURE ON (B)(6) 2025, AND ¿THE BLADE BROKE DISTALLY DURING OSTEOTOMY¿. THE PROCEDURE WAS COMPLETED WITH THE USE OF AN UNKNOWN ALTERNATE ¿BACKUP BLADE¿. FURTHER ASSESSMENT FOUND FRAGMENTS FELL INTO THE SURGICAL SITE AND ALL FRAGMENTS WERE RETRIEVED WITH A FORCEPS-LIKE INSTRUMENT. THERE WAS NO REPORT OF INJURY, MEDICAL/SURGICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22736990 ↗
  • MalfunctionJun 16, 2025Material Separation; Material Separation

    A DISTRIBUTOR REPORTED ON BEHALF OF A CUSTOMER THAT THE TN190-127-05, MCLASS OSCILLATING SAW BLADE 19 X 1.27 (0.050") X 105 MM DEVICE WAS USED IN A TOTAL KNEE ARTHROPLASTY PROCEDURE ON 21MAY25, AND ¿WHEN USING THIS BLADE TO CUT BONE, THE BASE OF THE BLADE BROKE.¿. THE PROCEDURE WAS COMPLETED WITHOUT THE USE OF AN ALTERNATE DEVICE AND NO REPORTED DELAY. FURTHER ASSESSMENT FOUND THE DEVICE FRAGMENTED AND FELL INTO THE SURGICAL SITE. ALL FRAGMENTS WERE REMOVED WITH A "FORCEPS-LIKE INSTRUMENT". THERE WAS NO REPORT OF INJURY, MEDICAL/SURGICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22212637 ↗
  • MalfunctionDec 31, 2024Material Separation; Material Separation

    A DISTRIBUTOR REPORTED ON BEHALF OF A CUSTOMER THAT THE TN190-127-05, MCLASS OSCILLATING SAW BLADE 19 X 1.27 (0.050") X 105 MM DEVICE WAS USED IN A TOTAL KNEE ARTHROPLASTY PROCEDURE ON (B)(6) 2024, AND ¿THIS BLADE BROKE IN THE TIP AND MIDDLE PART DURING USE. IT WAS USED IN TKA AND THE BLADE WAS REPORTEDLY BROKEN DURING A OSTEOTOMY.¿. FURTHER ASSESSMENT FOUND THAT THE DEVICE FRAGMENTED INTO THE SURGICAL SITE AND ALL FRAGMENTS WERE "RETRIEVED WITH AN INSTRUMENT SUCH AS FORCEPS". THE PROCEDURE WAS COMPLETED WITHOUT THE USED OF AN ALTERNATE DEVICE, AND NO DELAY. THERE WAS NO INJURY, MEDICAL/SURGICAL INTERVENTION OR EXTENDED HOSPITALIZATION REQUIRED FOR THE PATIENT. THE PATIENT'S CURRENT STATUS IS "NO ISSUES". THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21046905 ↗
  • MalfunctionOct 25, 2024Material Fragmentation; Material Fragmentation

    THE SALES REPRESENTATIVE REPORTED ON BEHALF OF THE CUSTOMER THAT THE TN190-127-05, MCLASS OSCILLATING SAW BLADE 19 X 1.27 (0.050") X 105 MM WAS BEING USED AND ¿BROKE DURING A TKA. THE SURGEON WAS PERFORMING A CUT TO THE PATIENT¿S FEMUR WHEN THE BLADE BROKE UNEXPECTEDLY INSIDE OF THE JIG. THERE WAS NO HARM TO THE PATIENT OR STAFF, AND ONLY A MINOR DELAY TO THE CASE.¿. ALL FRAGMENTS WERE RETRIEVED FROM THE SURGICAL SITE. THERE WAS NO IMPACT OR INJURY FOR THE PATIENT. THIS REPORT IS BEING RAISED DUE TO THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20534341 ↗
  • MalfunctionAug 8, 2024Material Fragmentation; Material Fragmentation

    THE DISTRIBUTOR REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE DEVICE, TN190-127-05, MCLASS OSC SAW BLADE 19MM X 1.27MM (0.050 INCH) X 105MM, WAS BEING USED DURING A TOTAL KNEE ARTHROPLASTY PROCEDURE ON (B)(6) 2024 WHEN IT WAS REPORTED, ¿IT WAS REPORTED THAT THIS BLADE BROKE IN THE MIDDLE PART DURING USE.¿. FURTHER ASSESSMENT FOUND THAT THE DEVICE FRAGMENTED INTO THE PATIENT AND THE FRAGMENTATION WAS RETRIEVED WITH A ¿FORCEPS-LIKE¿ INSTRUMENT. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR HOSPITALIZATION FOR THE PATIENT. THIS REPORT IS BEING RAISED DUE TO THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19937414 ↗
  • MalfunctionOct 23, 2023Material Fragmentation; Material Fragmentation

    THE DISTRIBUTOR REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE TN190-127-05, MCLASS OSC SAW BLADE 19MM X 1.27MM (0.050 INCH)X 105MM WAS BEING USED DURING A TOTAL KNEE ARTHROPLASTY PROCEDURE ON (B)(6) 2023 WHEN IT WAS REPORTED ¿THIS BLADE BROKE IN THE TIP AND MIDDLE PART DURING USE. IT WAS USED IN TKA AND THE BLADE WAS REPORTEDLY BROKEN DURING OSTEOTOMY.¿. FURTHER ASSESSMENT QUESTIONING FOUND THAT THE DEVICE FRAGMENTED INTO THE SURGICAL SITE AND WAS REMOVED WITH THE USE OF FORCEP LIKE INSTRUMENT. THE PROCEDURE WAS COMPLETED WITHOUT THE USE OF AN ALTERNATE DEVICE AND NO DELAY WAS REPORTED. THE CURRENT STATUS OF THE PATIENT WAS REPORTED AS ¿THERE IS NO PROBLEM¿. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR EXTENDED HOSPITALIZATION FOR THE PATIENT OR USER. THIS REPORT IS BEING RAISED ON THE REPORTED MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17986398 ↗
  • MalfunctionSep 18, 2023Material Fragmentation; Material Fragmentation

    THIS DISTRIBUTOR REPORTED ON BEHALF OF THEIR CUSTOMER THAT THE TN190-127-05, MCLASS OSC SAW BLADE 19MM X 1.27MM (0.050 INCH) X 105MM WAS BEING USED IN A TOTAL KNEE ARTHROPLASTY ON (B)(6) 2023 AND THAT "THIS BLADE BROKE IN THE TIP AND MIDDLE PART DURING USE. IT WAS USED IN TKA AND THE BLADE WAS REPORTEDLY BROKEN DURING A POSTERIOR FEMORAL OSTEOTOMY. THE HANDPIECE WAS A PRO9350 / TITAN PRIMECUT OSCILLATING SAW AND WAS USED IN HIGH SPEED MODE¿. PER ASSESSMENT, A FRAGMENT FELL INTO THE SURGICAL SITE AND WAS RETRIEVED. THE PROCEDURE WAS COMPLETED WITHOUT THE USE OF AN ALTERNATE DEVICE AND WITH NO REPORTED DELAY. THERE WAS NO REPORT OF INJURY, MEDICAL INTERVENTION, OR PROLONGED HOSPITALIZATION FOR THE PATIENT. THIS REPORT IS BEING RAISED ON THE BASIS OF MALFUNCTION WITH POTENTIAL FOR INJURY UPON REOCCURRENCE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17765997 ↗

FDA clearance and classification

The FDA regulates product code GFA (blade, saw, general & plastic surgery, surgical) under 21 CFR 878.4820 as a Class I device. 21 CFR 878.4820 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the MClass TN190-127-05

Has the MClass TN190-127-05 been recalled?

No FDA recall record in our data names this exact device identifier (DI 10845854021224), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the MClass TN190-127-05?

The FDA's MAUDE database lists 7 adverse event reports for this device, received between Sep 18, 2023 and Aug 7, 2025. In those reports, the most common specific device problems are “Material Fragmentation” (4), “Material Separation” (2) and “Fracture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the MClass TN190-127-05?

None of the reports are classified as deaths, 0 as injuries and 7 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the MClass TN190-127-05 FDA approved?

Devices of this type (product code GFA) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Conmed Corporation.

Who makes the MClass TN190-127-05, and is it still sold?

The FDA's device database lists Conmed Corporation as the company responsible for it (brand MClass, model TN190-127-05). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL devices

All BLADE, SAW, GENERAL & PLASTIC SURGERY, SURGICAL devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page