NUVISION NAV Ultrasound Catheter FG12081Recalls & reported problems
Biosense Webster Inc · NUVISION ICE NAV CATHETER · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10846835026559), received between Dec 15, 2025 and Mar 16, 2026 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Communication or Transmission Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Communication or Transmission Problem1
- Excessive Heating1
- Overheating of Device1
- Pumping Stopped1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionMar 16, 2026Overheating of Device; Excessive Heating
IT WAS REPORTED THAT A PATIENT UNDERWENT A VENTRICULAR TACHYCARDIA ABLATION PROCEDURE WITH A NUVISION ULTRASOUND CATHETER AND THE PROBE WAS OVERHEATING. A WARNING DISPLAYED, INDICATING IT WAS GETTING TOO HOT, IT FROZE AND THEN CUT OFF. THE CATHETER AND CABLE WERE RESEATED WITHOUT RESOLUTION. THE SWIFTLINK WAS RESEATED WITHOUT RESOLUTION. THE CATHETER WOULD COOL, AND WHEN TURNED BACK ON THE ISSUE REPEATED. THE CATHETER WAS REPLACED AND THE ISSUE RESOLVED. THE PROCEDURE CONTINUED WITH NO FURTHER ISSUES. NO PATIENT CONSEQUENCES WERE REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24607574 ↗MalfunctionJan 20, 2026Communication or Transmission Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT AN IDIOPATHIC VENTRICULAR TACHYCARDIA (IDVT) PROCEDURE WITH A NUVISION NAV ULTRASOUND CATHETER FOR WHICH BIOSENSE WEBSTER¿S PRODUCT ANALYSIS LAB (PAL) IDENTIFIED A HOLE IN THE TIP AREA. IT WAS INITIALLY REPORTED BY THE CUSTOMER THAT WHEN CONNECTING THE NUVISION NAV CATHETER, THE S70 ULTRASOUND MACHINE HAD A RED ERROR "PROBE NOT RECOGNIZED". NO ERRORS ON THE CARTO 3 SYSTEM. THE CATHETER CONNECTIONS WERE RESEATED, AND DIFFERENT PORTS WERE USED, WITHOUT RESOLUTION. THE CATHETER WAS REPLACED, AND THE ISSUE RESOLVED. THE PROCEDURE WAS CONTINUED AND COMPLETED. THERE WAS NO PATIENT CONSEQUENCE. THE CUSTOMER'S REPORTED RECOGNITION ISSUE IS NOT CONSIDERED TO BE MDR REPORTABLE SINCE THE POTENTIAL RISK THAT IT COULD CAUSE OR CONTRIBUTE TO A SERIOUS INJURY OR DEATH TO THE OPERATOR OR PATIENT IS REMOTE. ON (B)(6) 2025, THE BWI PAL REVEALED THAT A VISUAL INSPECTION OF THE RETURNED DEVICE FOUND A HOLE IN THE TIP AREA. THE FINDING WAS REVIEWED AND ASSESSED THE ISSUE OF A ¿HOLE¿ AS AN MDR REPORTABLE MALFUNCTION SINCE THE INTEGRITY OF THE DEVICE HAS BEEN COMPROMISED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24127304 ↗MalfunctionDec 15, 2025Pumping Stopped
CATHETER ENTERED THE BODY, WORKED FOR THE MAJORITY OF THE CASE. THEN IT FROZE AND WOULD NOT UNFREEZE. MD REQUESTED DIFFERENT BRAND ICE CATHETER. PROBLEM SOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23802470 ↗
Other Catheter, ultrasound, intravascular devices
- OptiCross H749518100Boston Scientific Corporation · Catheter, ultrasound, intravascular2 deaths457 reports
- OptiCross™ HD H74939352030Boston Scientific Corporation · Catheter, ultrasound, intravascular1 death436 reports
- ViewFlex™ D087031Irvine Biomedical, Inc. · Catheter, ultrasound, intravascular3 deaths341 reports
- OptiCross 18 H7493932800180Boston Scientific Corporation · Catheter, ultrasound, intravascular186 reports
- OptiCross™ 6 HD H74939354080Boston Scientific Corporation · Catheter, ultrasound, intravascular4 deaths177 reports
- Visions PV .014P RX Digital IVUS Catheter 014RPhilips Image Guided Therapy Corporation · Catheter, Ultrasound, Intravascular1 recall1 death84 reports
- Visions PV .018 Digital IVUS Catheter 86700Philips Image Guided Therapy Corporation · Catheter, Ultrasound, Intravascular1 recall67 reports
- OptiCross™ HD H74939352040Boston Scientific Corporation · Catheter, ultrasound, intravascular3 deaths116 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page