MYNXGRIP MX6721Recalls & reported problems
Cordis US Corp. · MynxGrip 6F/7F · Class 3
All models of MYNXGRIP (2)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
Quick summary
This Cordis MynxGrip vascular closure device is used to close the opening in an artery after a procedure. Among the 1,354 reports, some describe a loss of pressure, parts rupturing, or the device not positioning or firing properly, and others describe the device meeting resistance in the sheath so another closure device was used. The reports include 3 deaths, 88 injuries and 1,263 malfunctions. No recalls name this device.
AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.
- Adverse event reports
- 1,336
- Deaths reported
- 3
- Injuries reported
- 88
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1,336 adverse event reports that list this exact device (DI 10862028000410), received between May 7, 2018 and Sep 28, 2026 — classified as 3 deaths, 88 injuries, 1,245 malfunctions.
The most frequently reported specific device problem is “Decrease in Pressure” (307 reports).
3 other recalls cover devices cleared under the same FDA submission (P040044); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Decrease in Pressure307
- Material Rupture272
- Positioning Failure155
- Failure to Fire130
- Failure to Advance100
- Activation, Positioning or Separation Problem78
- Material Puncture/Hole76
- Appropriate Device Problem Term/Code Not Available56
Patient problems
- No Clinical Signs, Symptoms or Conditions786
- No Consequences Or Impact To Patient428
- No Known Impact Or Consequence To Patient42
- Hematoma34
- Hemorrhage/Blood Loss/Bleeding12
- Pseudoaneurysm8
- Local Reaction5
- Unspecified Infection5
Recent adverse event reports
The 25 most recent of 1,336 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 28, 2026Failure to Fire
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50914325 ↗MalfunctionSep 22, 2026Failure to Fire
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50859669 ↗MalfunctionSep 15, 2026Failure to Fire
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50777953 ↗MalfunctionSep 8, 2026Decrease in Pressure; Material Rupture
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50667787 ↗MalfunctionAug 23, 2026Decrease in Pressure; Material Rupture
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50395257 ↗MalfunctionAug 7, 2026Migration
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50176829 ↗MalfunctionAug 7, 2026Failure to Fire
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50176616 ↗MalfunctionAug 4, 2026Decrease in Pressure; Material Rupture
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50134282 ↗MalfunctionJun 9, 2026Decrease in Pressure; Material Rupture
AS REPORTED, A DEVICE FAILURE OCCURRED WITH TWO (2) 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD). THERE WAS NO REPORTED PATIENT INJURY. ONE DEVICE BALLOON DEFLATED IN THE VESSEL, AND CALCIUM WAS SUSPECTED. A SECOND DEVICE SEALANT STARTED TO DEPLOY WHEN REMOVING THE DEVICE FROM THE PACKAGE. BOTH DEVICES FAILED IN THE SAME PROCEDURE AND SAME PATIENT. THE DEPLOYER WAS IN TRAINING AND IDENTIFIED AS A FELLOW. A NON-CORDIS SHEATH INTRODUCER WAS USED. PRESENCE OF CALCIUM IN THE VICINITY OF THE PUNCTURE SITE WAS REPORTED. HEMOSTASIS WAS ACHIEVED WITH MANUAL COMPRESSION FOR LESS THAN 30 MINUTES. THE DEVICE WAS REPORTED TO HAVE BEEN STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THE DEVICES WERE DISCARDED AT SITE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25451385 ↗MalfunctionJun 9, 2026Failure to Fire
AS REPORTED, THERE WAS NO ADVANCER TUBE IN A 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) AFTER SHUTTLING DOWN. THE DEVICE WAS REMOVED, AND MANUAL COMPRESSION WAS HELD FOR LESS THAN 30 MINUTES WITH HEMOSTASIS ACHIEVED AND NO ISSUES. THERE WAS NO REPORTED PATIENT INJURY. THE CUSTOMER STATED THAT THEY SHUTTLED DOWN TO A FULL STOP. WHEN THE USERS SHUTTLED DOWN TO A FULL STOP, THERE WAS NO SIGNIFICANT RESISTANCE AND NO UNUSUAL FORCE WAS APPLIED WHEN RETRACTING THE SHEATH. THE ADVANCER TUBE WAS NOT ENGAGED OR VISIBLE. THE MYNX VASCULAR CLOSURE DEVICE (VCD) WAS USED IN BOTH DIAGNOSTIC AND INTERVENTIONAL PROCEDURES. A RETROGRADE APPROACH WAS USED. THE MYNX VASCULAR CLOSURE DEVICE (VCD) WAS STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). A NON-CORDIS 6F SHEATH WAS USED. THE FEMORAL ARTERY¿S SUITABILITY WAS VERIFIED ON ANGIOGRAPHY, INCLUDING THE INSERTION ANGLE OF THE VASCULAR SHEATH INTRODUCER. THE VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5 MM. THE SHEATH WAS NOT KINKED OR BENT. THE SEALANT WAS NOT STUCK TO DEVICE COMPONENTS. THE DEVICE STORAGE TEMPERATURE DID NOT EXCEED 25 °C. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25445318 ↗MalfunctionJun 9, 2026Failure to Fire
AS REPORTED, THERE WAS NO ADVANCER TUBE IN A 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) AFTER SHUTTLING DOWN. THE DEVICE WAS REMOVED, AND MANUAL COMPRESSION WAS HELD FOR LESS THAN 30 MINUTES WITH HEMOSTASIS ACHIEVED AND NO ISSUES. THERE WAS NO REPORTED PATIENT INJURY. THE CUSTOMER STATED THAT THEY SHUTTLED DOWN TO A FULL STOP. WHEN THE USER SHUTTLED DOWN TO A FULL STOP, THERE WAS NO SIGNIFICANT RESISTANCE AND NO UNUSUAL FORCE APPLIED WHEN RETRACTING THE SHEATH. THE ADVANCER TUBE WAS NOT ENGAGED OR VISIBLE. THE MYNX VCD WAS USED IN BOTH DIAGNOSTIC AND INTERVENTIONAL PROCEDURES. A RETROGRADE APPROACH WAS USED. THE MYNX VCD WAS STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). A 6F NON-CORDIS SHEATH WAS USED. THE FEMORAL ARTERY¿S SUITABILITY WAS VERIFIED ON ANGIOGRAPHY, INCLUDING THE INSERTION ANGLE OF THE VASCULAR SHEATH INTRODUCER. THE VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5 MM. THERE WAS NO PRESENCE OF PERIPHERAL VASCULAR DISEASE (PVD) OR CALCIUM IN THE VICINITY OF THE PUNCTURE SITE. THE SHEATH WAS NOT KINKED OR BENT. THE PATIENT WAS NOT MORBIDLY OBESE. THE SEALANT WAS NOT STUCK TO DEVICE COMPONENTS. THE DEVICE STORAGE TEMPERATURE DID NOT EXCE
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25444955 ↗MalfunctionJun 9, 2026Failure to Fire
AS REPORTED, THERE WAS NO ADVANCER TUBE IN A 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) AFTER SHUTTLING DOWN. THE DEVICE WAS REMOVED, AND MANUAL COMPRESSION WAS HELD FOR LESS THAN 30 MINUTES WITH HEMOSTASIS ACHIEVED AND NO ISSUES. THERE WAS NO REPORTED PATIENT INJURY. THE CUSTOMER STATED THAT THEY SHUTTLED DOWN TO A FULL STOP. NO SIGNIFICANT RESISTANCE, UNUSUAL FORCE, OR UNUSUAL SHEATH RETRACTION FORCE OCCURRED WHEN SHUTTLING DOWN TO A FULL STOP. THE ADVANCER TUBE WAS NOT ENGAGED OR VISIBLE. THE MYNX VASCULAR CLOSURE DEVICE (VCD) WAS USED IN BOTH DIAGNOSTIC AND INTERVENTIONAL PROCEDURES. THE APPROACH WAS RETROGRADE. THE MYNX VASCULAR CLOSURE DEVICE (VCD) WAS STORED AND PREPPED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). A 6F NON-CORDIS SHEATH WAS USED. FEMORAL ARTERY SUITABILITY WAS VERIFIED ON ANGIOGRAPHY, INCLUDING THE INSERTION ANGLE OF THE VASCULAR SHEATH INTRODUCER. THE VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5MM. THERE WAS NO PRESENCE OF PERIPHERAL VASCULAR DISEASE (PVD) OR CALCIUM IN THE VICINITY OF THE PUNCTURE SITE. THE SHEATH WAS NOT KINKED OR BENT. THE SEALANT WAS NOT STUCK TO DEVICE COMPONENTS. THE DEVICE STORAGE TEMPERATURE DID NOT EXCEED 25°C. T
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25444951 ↗MalfunctionJun 9, 2026Failure to Fire
AS REPORTED, THERE WAS NO ADVANCER TUBE IN A 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) AFTER SHUTTLING DOWN. THE DEVICE WAS REMOVED, AND MANUAL COMPRESSION WAS HELD FOR LESS THAN 30 MINUTES WITH HEMOSTASIS ACHIEVED AND NO ISSUES. THERE WAS NO REPORTED PATIENT INJURY. THE CUSTOMER STATED THAT THEY SHUTTLED DOWN TO A FULL STOP. THERE WAS NO SIGNIFICANT RESISTANCE WHEN SHUTTLING DOWN, AND NO UNUSUAL FORCE WAS APPLIED WHEN RETRACTING THE SHEATH. THE ADVANCER TUBE WAS NOT ENGAGED OR VISIBLE. THE MYNX VASCULAR CLOSURE DEVICE (VCD) WAS USED IN BOTH DIAGNOSTIC AND INTERVENTIONAL PROCEDURES. THE APPROACH WAS RETROGRADE. THE MYNX VASCULAR CLOSURE DEVICE (VCD) WAS STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). A NON-CORDIS 6F SHEATH WAS USED WITH THE DEVICE. FEMORAL ARTERY SUITABILITY WAS VERIFIED ON ANGIOGRAPHY, INCLUDING THE INSERTION ANGLE OF THE VASCULAR SHEATH INTRODUCER. THE VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5 MM. THERE WAS NO PERIPHERAL VASCULAR DISEASE (PVD) OR CALCIUM IN THE VICINITY OF THE PUNCTURE SITE. THE SHEATH WAS NOT KINKED OR BENT. THE SEALANT WAS NOT STUCK TO DEVICE COMPONENTS. THE DEVICE STORAGE TEMPERATURE DID NOT EXCEED 25 °C
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25444684 ↗MalfunctionJun 9, 2026Failure to Fire
AS REPORTED, THERE WAS NO ADVANCER TUBE IN A 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) AFTER SHUTTLING DOWN. THE DEVICE WAS REMOVED, AND MANUAL COMPRESSION WAS HELD FOR LESS THAN 30 MINUTES WITH HEMOSTASIS ACHIEVED AND NO ISSUES. THERE WAS NO REPORTED PATIENT INJURY. THE CUSTOMER STATED THAT THEY SHUTTLED DOWN TO A FULL STOP. THE OPERATOR STATED THAT THE MYNXGRIP VCD WAS CUT OPEN WITH A SCALPEL, AND THERE WAS NO ADVANCER TUBE PRESENT. WHEN THE USER SHUTTLED DOWN TO A FULL STOP, THERE WAS NO SIGNIFICANT RESISTANCE AND NO UNUSUAL FORCE WAS APPLIED WHEN RETRACTING THE SHEATH. THE ADVANCER TUBE WAS NOT ENGAGED OR VISIBLE. THE MYNX VCD WAS USED IN BOTH DIAGNOSTIC AND INTERVENTIONAL PROCEDURES. A RETROGRADE APPROACH WAS USED. THE MYNX VCD WAS STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). A 6F NON-CORDIS SHEATH WAS USED. FEMORAL ARTERY SUITABILITY WAS VERIFIED ON ANGIOGRAPHY, INCLUDING THE INSERTION ANGLE OF THE VASCULAR SHEATH INTRODUCER. VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5 MM. THERE WAS NO PRESENCE OF PERIPHERAL VASCULAR DISEASE (PVD) OR CALCIUM IN THE VICINITY OF THE PUNCTURE SITE. THE SHEATH WAS NOT KINKED OR BENT. THE SEALANT WAS NOT ST
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25444468 ↗MalfunctionJun 2, 2026Decrease in Pressure; Material Rupture
AS REPORTED, UPON PULLING BACK A 6/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) THE WHOLE DEVICE PULLED THROUGH ARTERIOTOMY AND THE BALLON INDICATOR WAS FULLY UP BUT LOOKED LIKE BALLOON WAS DEFLATED/DID NOT KEEP AIR. MANUAL PRESSURE WAS HELD FOR HEMOSTASIS. THERE WAS NO PATIENT INJURY. THE PHYSICIAN PREPPED THE DEVICE PER THE IFU. THE DEVICE WILL BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25365392 ↗MalfunctionJun 1, 2026Failure to Fire
AS REPORTED, UPON DEPLOYMENT OF A 6F/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) IT GOT STUCK AND WOULD NOT DELIVER OR DEPLOY. THERE WAS NO REPORTED PATIENT INJURY. ADDITIONAL INFORMATION WAS REQUESTED BUT NOT PROVIDED.THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25356311 ↗MalfunctionMay 21, 2026Failure to Fire
AS REPORTED, THE MYNXGRIP HAD A DEPLOYMENT FAILURE. THERE WAS NO REPORTED INJURY TO THE PATIENT. ADDITIONAL INFORMATION AND DEVICE RETURN WAS REQUESTED; HOWEVER, NEITHER WERE OBTAINED AFTER MULTIPLE ATTEMPTS MADE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25246549 ↗MalfunctionMay 21, 2026Failure to Fire
AS REPORTED, A 6F/7F MYNX GRIP VASCULAR CLOSURE DEVICE DEPLOYMENT FAILED. THERE WAS NO REPORTED INJURY TO THE PATIENT. ADDITIONAL INFORMATION AND DEVICE RETURN WAS REQUESTED; HOWEVER, NEITHER WERE OBTAINED AFTER MULTIPLE ATTEMPTS MADE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25246285 ↗MalfunctionMay 19, 2026Failure to Fire
AS REPORTED, THE "SEALANT" OF A 6/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) COULD NOT BE ADVANCED. THERE WAS NO REPORTED PATIENT INJURY. THE USER WAS CERTIFIED AND EXPERIENCED FOR 10 YEARS. THE MYNX CONTROL VASCULAR CLOSURE DEVICE (VCD) WAS USED DURING AN INTERVENTIONAL PROCEDURE WITH AN ANTEGRADE APPROACH. A NON-CORDIS SHEATH INTRODUCER WAS USED. FEMORAL ARTERY SUITABILITY WAS VERIFIED BY ANGIOGRAPHY OR VENOGRAPHY, INCLUDING CONFIRMATION OF AN APPROPRIATE INSERTION ANGLE. THE DEVICE WAS USED IN THE FEMORAL ARTERY. NO VESSEL TORTUOSITY WAS REPORTED, AND THERE WAS NO REPORTED PRESENCE OF PERIPHERAL VASCULAR DISEASE OR CALCIUM AT THE PUNCTURE SITE. HEMOSTASIS WAS ACHIEVED USING MANUAL COMPRESSION. THE USER DID NOT SHUTTLE DOWN COMPLETELY, THERE WAS NO SIGNIFICANT RESISTANCE DURING SHUTTLING, AND NO UNUSUAL FORCE WAS APPLIED WHEN RETRACTING THE SHEATH. THE DEVICE WAS NOT RETURNED FOR EVALUATION AS PREVIOUSLY EXPECTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25224679 ↗MalfunctionMay 19, 2026Decrease in Pressure; Material Rupture
AS REPORTED, THE BALLOON OF A 6/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) POPPED PRIOR TO SUCCESSFUL CLOSURE. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE WAS USED DURING A PERIPHERAL CASE. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25216923 ↗MalfunctionMay 18, 2026Decrease in Pressure
AS REPORTED, THE BALLOON OF A 6F¿7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) RUPTURED DURING DEPLOYMENT. MANUAL PRESSURE WAS APPLIED AND HEMOSTASIS WAS ACHIEVED. THERE WAS NO REPORTED PATIENT INJURY. THERE WERE NO DAMAGES FOUND ON THE DEVICE OR DEVICE PACKAGING PRIOR TO OPENING. THE DEVICE WAS STORED AND PREPPED IN ACCORDANCE WITH THE INSTRUCTIONS FOR USE (IFU). THE USER WAS TRAINED IN THE USE OF THE DEVICE. THE DEVICE WAS USED IN AN INTERVENTIONAL PROCEDURE WITH A RETROGRADE APPROACH. A 6F NON-CORDIS SHEATH INTRODUCER WAS USED. THE FEMORAL ARTERY SUITABILITY, INCLUDING INSERTION ANGLE OF THE VASCULAR SHEATH INTRODUCER, WAS VERIFIED ON ANGIOGRAPHY OR VENOGRAPHY. THE VESSEL TYPE WAS ARTERIAL, AND THE DEVICE WAS USED IN THE FEMORAL VESSEL. THE VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5 MM. THERE WAS NO VESSEL TORTUOSITY AND LITTLE PERIPHERAL VASCULAR DISEASE (PVD)/CALCIUM NEAR THE PUNCTURE SITE. THE BALLOON LOST PRESSURE DURING PATIENT USE AT THE 2ND STOP. THERE WAS NO PRIOR PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY (PTA), STENT, OR VASCULAR GRAFT IN THE COMMON FEMORAL ARTERY OR VEIN. THERE WAS NO VISIBLE DAMAGE TO THE DISTAL END OF THE SHEATH AFTER REMOVAL. THE DEVICE W
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25208196 ↗MalfunctionMay 15, 2026Decrease in Pressure; Material Rupture
AS REPORTED, THE BALLOON OF A 6F¿7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) RUPTURED AFTER INSERTION INTO THE PATIENT. MANUAL PRESSURE WAS HELD ON THE TABLE FOR 20 MINUTES TO ACHIEVE HEMOSTASIS. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE WAS INSERTED INTO THE PATIENT AND FAILURE WAS NOTED DURING USE. THE DEVICE WAS USED IN AN INTERVENTIONAL PROCEDURE WITH A RETROGRADE APPROACH. THE DEPLOYER WAS MYNX CERTIFIED. A NON-CORDIS SHEATH INTRODUCER WAS USED. THE FEMORAL ARTERY SUITABILITY AND SHEATH INSERTION ANGLE WERE VERIFIED ON ANGIOGRAPHY OR VENOGRAPHY. THE DEVICE WAS USED IN THE FEMORAL ARTERIAL VESSEL, AND THE VESSEL DIAMETER WAS VERIFIED TO BE GREATER THAN OR EQUAL TO 5 MM. THERE WAS NO PRESENCE OF PERIPHERAL VASCULAR DISEASE OR CALCIUM IN THE VICINITY OF THE PUNCTURE SITE. THE DEVICE WAS STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE. THERE WAS NO PRIOR PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY, STENT, OR VASCULAR GRAFT IN THE COMMON FEMORAL ARTERY OR VEIN. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION DUE TO THE ACCOUNT¿S INTERNAL POLICY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25186546 ↗MalfunctionMay 11, 2026Migration
AS REPORTED, AN INCOMPLETE DEPLOYMENT OCCURRED WHEN A 6/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) WAS USED, WITH THE POLYETHYLENE GLYCOL (PEG) SEALANT REMAINING FULLY ATTACHED TO THE DEVICE WHEN REMOVED. MANUAL COMPRESSION WAS DONE FOR LESS THAN 30 MINUTES TO ACHIEVE HEMOSTASIS. THERE WAS NO REPORTED PATIENT INJURY. THE PROCEDURE WAS PERFORMED USING A RETROGRADE APPROACH. THERE WERE NO REPORTED ISSUES REGARDING VESSEL ACCESS. THE USER WAS TRAINED TO THE DEVICE. THE DEVICE WAS STORED AND PREPARED ACCORDING TO THE INSTRUCTIONS FOR USE. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25137081 ↗MalfunctionMay 5, 2026Failure to Advance
AS REPORTED, THE SHUTTLE OF A 6F¿7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) DID NOT SHUTTLE DOWN TO DEPLOY. THERE WAS NO REPORTED PATIENT INJURY. THE UNUSED DEVICES WERE RETURNED WHILE THE FAILED DEVICES WERE NOT SAVED. THE FAILURE OCCURRED DURING USE IN THE PATIENT. THE PROCEDURE WAS INTERVENTIONAL AND PERFORMED USING A RETROGRADE APPROACH. THE DEPLOYER WAS MYNX CERTIFIED. A 6F NON-CORDIS SHEATH WAS USED. THE FEMORAL ARTERY SUITABILITY, INCLUDING INSERTION ANGLE, WAS VERIFIED, AND THE VESSEL TYPE WAS ARTERIAL WITH A DIAMETER GREATER THAN OR EQUAL TO 5 MM, WITH NO PRESENCE OF PERIPHERAL VASCULAR DISEASE OR CALCIUM AT THE PUNCTURE SITE. HEMOSTASIS WAS ACHIEVED WITH MANUAL COMPRESSION FOR 30 MINUTES OR LESS. THE DEVICE WAS STORED AND PREPARED ACCORDING TO INSTRUCTIONS FOR USE. THERE WAS NO PRIOR PERCUTANEOUS TRANSLUMINAL ANGIOPLASTY, STENT, OR VASCULAR GRAFT IN THE VESSEL. NO VISIBLE DAMAGE WAS OBSERVED ON THE DISTAL END OF THE SHEATH AFTER REMOVAL. THE USER CONFIRMED THE SHUTTLE WAS FULLY DEPLOYED WITH NO SIGNIFICANT RESISTANCE AND NO UNUSUAL FORCE WAS APPLIED DURING SHEATH RETRACTION. THE DEVICE WILL NOT BE RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25085881 ↗MalfunctionMay 4, 2026Failure to Fire
AS REPORTED, THE PLUG OF A 6/7F MYNXGRIP VASCULAR CLOSURE DEVICE (VCD) COULD NOT BE RELEASED. THERE WAS NO REPORTED PATIENT INJURY. THE DEVICE WAS STORED AND PREPARED ACCORDING TO INSTRUCTIONS FOR USE. THE PROCEDURE WAS INTERVENTIONAL USING A RETROGRADE APPROACH, AND THE OPERATOR WAS MYNX CERTIFIED. THE FEMORAL ARTERY WAS USED, SUITABILITY AND VESSEL DIAMETER =5 MM WERE VERIFIED, WITH NO TORTUOSITY AND NO PERIPHERAL VASCULAR DISEASE OR CALCIFICATION PRESENT. HEMOSTASIS WAS ACHIEVED WITH MANUAL COMPRESSION FOR 20 MINUTES. THE DEVICE WAS FULLY SHUTTLED DOWN WITH NO RESISTANCE, NO UNUSUAL FORCE WAS APPLIED DURING SHEATH RETRACTION, AND THE ADVANCER TUBE WAS NOT ENGAGED OR VISIBLE. THE DEVICE IS BEING RETURNED FOR EVALUATION.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25068222 ↗
FDA clearance and classification
Approved through premarket approval (PMA) P040044 on Aug 17, 2005. Submitted by Cordis US Corporation as “Matrix Vascular Closure System (Vsg)”. The FDA review took 286 days. The FDA has since approved 107 supplements (changes to the device or its labeling), most recently on May 14, 2026. FDA record ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under P040044. One submission often covers many models, so check the product and lot details in each record.
- Z-0674-2024 · Nov 28, 2023 · Open, ClassifiedMYNXGRIP 5F, REF MX5021, Vascular Closure Device (VCD). Used to seal femoral arterial and femoral venous access sites.
- Z-0675-2024 · Nov 28, 2023 · Open, ClassifiedMYNXGRIP 6F/7F, REF MX6721, Vascular Closure Device (VCD). Used to seal femoral arterial and femoral venous access sites
- Z-2329-2016 · Jul 13, 2016 · Terminated6F/7F MynxGrip Vascular Closure Device; Product Model MX6721, Product Usage: The 6F/7F MynxGrip Vascular Closure Device is indicated for use to seal femoral arterial and femoral v
Common questions about the MYNXGRIP MX6721
Has the MYNXGRIP MX6721 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10862028000410), based on the FDA recall file dated Nov 27, 2026. However, 3 recalls involve devices cleared under the same FDA submission. They may or may not include this model, so check the product, model and lot details in those records.
What problems have been reported with the MYNXGRIP MX6721?
The FDA's MAUDE database lists 1,336 adverse event reports for this device, received between May 7, 2018 and Sep 28, 2026. In those reports, the most common specific device problems are “Decrease in Pressure” (307), “Material Rupture” (272) and “Positioning Failure” (155); the most common patient problems are “Hematoma” (34), “Hemorrhage/Blood Loss/Bleeding” (12) and “Pseudoaneurysm” (8). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the MYNXGRIP MX6721?
3 reports are classified as deaths, 88 as injuries and 1,245 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the MYNXGRIP MX6721 FDA approved?
It was approved through premarket approval (PMA) P040044 on Aug 17, 2005.
Is the MYNXGRIP MX6721 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Safe: it poses no known hazards in any MRI environment.
Who makes the MYNXGRIP MX6721, and is it still sold?
The FDA's device database lists Cordis US Corp. as the company responsible for it (brand MYNXGRIP, model MX6721). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Device, hemostasis, vascular devices
- Perclose™ ProStyle™ 12773-03Abbott Vascular Inc. · Device, hemostasis, vascular8 deaths17,987 reports
- Perclose ProGlide™ 12673-03Abbott Vascular Inc. · DEVICE, HEMOSTASIS, VASCULAR13 deaths10,576 reports
- ANGIO-SEAL 610130Terumo Medical Corporation · Device, hemostasis, vascular3 deaths1,626 reports
- MYNXGRIP MX5021Cordis US Corp. · Device, hemostasis, vascular2 recalls897 reports
- MANTA 2115Essential Medical, Inc. · Device, Hemostasis, Vascular14 deaths966 reports
- StarClose SE™ 14679-01Abbott Vascular Inc. · DEVICE, HEMOSTASIS, VASCULAR586 reports
- Cordis ExoSeal Vascular Closure Device EX500Cordis US Corp. · DEVICE, HEMOSTASIS, VASCULAR470 reports
- ANGIO-SEAL 610131Terumo Medical Corporation · Device, hemostasis, vascular1 death406 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page