Skip to content

InPen Smart Insulin Delivery System Lilly - BlueRecalls & reported problems

Companion Medical, Inc. · The InPen is a home-use reusable pen injector for single-patient use by people with diabetes under the supervision of an adult caregiver, or by a patient age 7 and older for the self-injection of a desired dose of insulin. The pen injector is compatible with Lilly Humalog® U-100 3.0 mL cartridges, Novo Nordisk Novolog® U-100 3.0 mL cartridges, and Novo Nordisk Fiasp® U-100 3.0 mL cartridges and single-use detachable and disposable pen needles (not included). The pen injector allows the user to dial the desired dose from 0.5 to 30 units in one-half (1/2) unit increments. The InPen dose calculator, a component of the InPen app, is indicated for the management of diabetes by people with diabetes under the supervision of an adult caregiver, or by a patient age 7 and older for calculating an insulin dose or carbohydrate intake based on user entered data. For an insulin dose based on amount of carbohydrates, a healthcare professional must provide patient-specific target blood glucose, insulin-to-carbohydrate ratio, and insulin sensitivity parameters to be programmed into the software prior to use. For an insulin dose based on fixed/variable meal sizes, a healthcare professional must provide patient-specific fixed doses/meal sizes to be programmed into the software prior to use. · Class 2

All models of InPen Smart Insulin Delivery System (5)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10862088000313), received between Jul 20, 2020 and Jul 20, 2020 — classified as 1 injury.

The most frequently reported specific device problem is “Low Readings” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Recalls naming this device

  1. Nov 8, 2022Class IIOpen, Classified

    Diabetes management app may crash immediately upon opening, while using the app and/or while app is running in the background, which may lead to inability to use the app. An error message may be displayed indicating the app has stopped or isn't responding. After the crash, a present dose reminder is not displayed, which may lead to delayed insulin therapy and potentially resulting in hyperglycemia.

    Z-0741-2023 · Root cause: Software design · Recall details · FDA record ↗

Most reported problems

Device problems

  • Low Readings1

Patient problems

  • Hypoglycemia1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 20, 2020Low Readings; Low Readings

    IT WAS REPORTED THAT A DISCREPANCY OCCURRED BETWEEN THE SELECTED DOSE AMOUNT AND (B)(6) LOGBOOK AMOUNT. ON (B)(6) 2020, THE PATIENT DOSED 5.5 UNITS OF INSULIN, HOWEVER THE LOGBOOK DISPLAYED 1.0 UNIT. THE PATIENT DOSED AN ADDITIONAL 4.5 UNITS OF INSULIN TO ACCOMMODATE THE DISCREPANCY. CONSEQUENTLY, THE PATIENT'S BLOOD GLUCOSE LEVELS DROPPED TO 37 MG/DL. THE PATIENT DRANK JUICE AND INJECTED GLUCAGON TO RAISE HER BLOOD GLUCOSE LEVELS. PROFESSIONAL MEDICAL ATTENTION WAS NOT REQUESTED BY THE PATIENT. THIS INPEN WAS NOT RETURNED, SO AN INVESTIGATION WAS NOT POSSIBLE AND A ROOT CAUSE COULD NOT BE DETERMINED. CLOUD DATA WAS REVIEWED AND SUPPORTED CUSTOMER ALLEGATION, HOWEVER A ROOT CAUSE COULD NOT BE DETERMINED. NO ADDITIONAL INFORMATION IS AVAILABLE.

    Patient problems: Hypoglycemia

    MAUDE report 10296191 ↗

Other Syringe, Piston devices

All Syringe, Piston devices →