Tempo Temporary Pacing Lead, Curved TC1106Recalls & reported problems
Bio Trace Medical · The BioTrace Medical Tempo Temporary Pacing Lead is designed for temporary intracardia pacing. The lead provides access to the right ventricle via either the femoral vein, subclavian vein or the internal jugular vein approach and may be shaped near the distal end to facilitate delivery. It is a radiopaque, polymeric lead featuring a balloon , active fixations, bipolar electrodes and a soft tip. · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10866899000210), received between Jan 17, 2020 and Jan 17, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Material Fragmentation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Material Fragmentation1
Patient problems
- Pericardial Effusion1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJan 17, 2020Material Fragmentation; Material Fragmentation
DURING THE PROCEDURE THE PATIENT EXPERIENCED A PERICARDIAL EFFUSION. DR. (B)(6) WHO PLACED THE TEMPO LEAD STATED THAT HE BELIEVED THAT THE PERFORATION OCCURRED DURING THE INITIAL PLACEMENT OF THE TEMPO LEAD. THIS IS SUPPORTED BY HIS STATEMENT THAT THE TEMPO LEAD WAS PLACED "WAY OUT" TO THE APEX OF THE RIGHT VENTRICLE AND IN SPITE OF THIS TYPICALLY OPTIMAL POSITION, PACE CAPTURE COULD NOT BE ATTAINED. DR. (B)(6) REPOSITIONED THE TEMPO LEAD TWICE AND WAS ULTIMATELY ABLE TO OBTAIN A CAPTURE THRESHOLD BELOW 1MA (GENERALLY CONSIDERED OPTIMAL). SUBSEQUENT TO PLACEMENT OF THE LEAD THE PATIENT WAS NOTED TO BE HYPOTENSIVE, WHICH WAS ULTIMATELY DETERMINED TO BE RELATED TO A PERICARDIAL EFFUSION. SURGERY WAS PERFORMED ON THE PATIENT TO CLOSE A SMALL PERFORATION IN THE APEX OF THE HEART. DR (B)(6) STATED THAT HE USED THE INTRODUCER AID TO ADVANCE THE TEMPO LEAD INTO THE INTRODUCER SHEATH AND THAT HE DID NOT HAVE ANY DIFFICULTY DURING TEMPO LEAD INSERTION OR PLACEMENT. HE STATED THAT THE SOFT TIP LOOKED NORMAL AT THE TIME OF THE FINAL POSITION IN THE APEX OF THE RIGHT VENTRICLE AND WAS NOT KINKED OR "OFFSET". HE ALSO STATED THAT THE PATIENT WAS (B)(6) AND AT RISK OF AN APICAL PERFORATION BY VIR
Patient problems: Pericardial Effusion
MAUDE report 9603633 ↗
Other Electrode, Pacemaker, Temporary devices
- N/A 006173PC. R. Bard, Inc. · ELECTRODE, PACEMAKER, TEMPORARY161 reports
- SWAN-GANZ D200F7Edwards Lifesciences LLC · ELECTRODE, PACEMAKER, TEMPORARY1 recall0 reports
- ETHICON TPW32Ethicon, LLC · ELECTRODE, PACEMAKER, TEMPORARY1 death46 reports
- ETHICON TPW20Ethicon, LLC · ELECTRODE, PACEMAKER, TEMPORARY39 reports
- N/A 520007PC. R. Bard, Inc. · ELECTRODE, PACEMAKER, TEMPORARY33 reports
- Pacel™ 401763St. Jude Medical Cardiovascular Division · ELECTRODE, PACEMAKER, TEMPORARY21 reports
- Pacel™ 401771St. Jude Medical Cardiovascular Division · ELECTRODE, PACEMAKER, TEMPORARY1 death16 reports
- SWAN-GANZ PACING TD CATHETER D205F7Edwards Lifesciences LLC · Electrode, Pacemaker, Temporary13 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page