Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10878528009464), received between Jul 6, 2018 and Jul 6, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Stretched” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Stretched1
Patient problems
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 6, 2018Stretched; Stretched
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
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7667227 ↗
Other DEVICE, NEUROVASCULAR EMBOLIZATION devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page