ORBIT GALAXY ENPOWER 641CF0824Recalls & reported problems
Medos International Sàrl · ORBIT GALAXY G2 microcoil Stretch Resistant Complex Fill Coil with Tight Distal Loop Technology 8mm x 24cm 190cm Contents: 1 Detachable Coil System Coil Type: Stretch Resistant Complex Fill Coil with Tight Distal Loop Technology · Class 2 · Implant
All models of ORBIT GALAXY ENPOWER (16)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10878528009631), received between May 29, 2019 and May 29, 2019 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Stretched” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Stretched2
Patient problems
- No Consequences Or Impact To Patient2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 29, 2019Stretched; Stretched
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE COIL EMBOLIZATION PROCEDURE TARGETING AN ANEURYSM ON THE LEFT INTERNAL CAROTID ARTERY (ICA), THE 8MM X 24CM ORBIT GALAXY G2 COIL (641CF0824 / S13607) WAS ONE OF TWO COILS THAT WERE USED IN; DURING COIL DELIVERY, THE COIL BECAME STRETCHED INSIDE THE SL-10® MICROCATHETER (STRYKER). THE REPORTED ISSUE OCCURRED DURING COIL WITHDRAWAL FOR REPOSITIONING IN THE ANEURYSM. CONTINUOUS FLUSH HAD BEEN MAINTAINED THROUGH THE MICROCATHETER. THERE WAS NO RESISTANCE BETWEEN THE GUIDEWIRE AND THE MICROCATHETER WHEN THE TARGET SITE WAS BEING ACCESSED. THERE WERE NO KINKS ON THE MICROCATHETER THAT COULD HAVE CONTRIBUTED TO THE REPORTED ISSUE; THERE WAS NO REPORT OF COIL ENTANGLEMENT THAT COULD HAVE CONTRIBUTED TO THE REPORTED ISSUE OF THE COIL BECOMING STRETCHED DURING THE COIL DELIVERY ATTEMPT. THE COIL WAS REPLACED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO FLOW RESTRICTION OR REDUCTION AS A RESULT OF THE ISSUE REPORTED; THERE WAS ALSO NO REPORT OF PATIENT INJURY OR COMPLICATION, NO SIGNIFICANT PROCEDURAL DELAY AS A RESULT OF THE REPORTED ISSUE. IT WAS REPORTED THAT THE PRODUCT IS AVAILABLE TO BE RETURNED FOR EVALUATION AND ANALY
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8650385 ↗MalfunctionMay 29, 2019Stretched; Stretched
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING THE COIL EMBOLIZATION PROCEDURE TARGETING AN ANEURYSM ON THE LEFT INTERNAL CAROTID ARTERY (ICA), THE 8MM X 24CM ORBIT GALAXY G2 COIL (641CF0824 / S13665) WAS ONE OF TWO COILS THAT WERE USED IN; DURING COIL DELIVERY, THE COIL BECAME STRETCHED INSIDE THE SL-10® MICROCATHETER (STRYKER). THE REPORTED ISSUE OCCURRED DURING COIL WITHDRAWAL FOR REPOSITIONING IN THE ANEURYSM. CONTINUOUS FLUSH HAD BEEN MAINTAINED THROUGH THE MICROCATHETER. THERE WAS NO RESISTANCE BETWEEN THE GUIDEWIRE AND THE MICROCATHETER WHEN THE TARGET SITE WAS BEING ACCESSED. THERE WERE NO KINKS ON THE MICROCATHETER THAT COULD HAVE CONTRIBUTED TO THE REPORTED ISSUE; THERE WAS NO REPORT OF COIL ENTANGLEMENT THAT COULD HAVE CONTRIBUTED TO THE REPORTED ISSUE OF THE COIL BECOMING STRETCHED DURING THE COIL DELIVERY ATTEMPT. THE COIL WAS REPLACED, AND THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO FLOW RESTRICTION OR REDUCTION AS A RESULT OF THE ISSUE REPORTED; THERE WAS ALSO NO REPORT OF PATIENT INJURY OR COMPLICATION, NO SIGNIFICANT PROCEDURAL DELAY AS A RESULT OF THE REPORTED ISSUE. IT WAS REPORTED THAT THE PRODUCT IS AVAILABLE TO BE RETURNED FOR EVALUATION AND ANALY
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8650383 ↗
Other DEVICE, NEUROVASCULAR EMBOLIZATION devices
- POD RBYPODJ60-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION355 reports
- Penumbra System SCH1Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION295 reports
- RUBY Coil RBY4C0860-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION276 reports
- Smart Coil 400SMTHXSFT0208Penumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION165 reports
- Penumbra System RH1-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION154 reports
- Optima Coil System OPTI0208CSS10Balt USA LLC · Device, Neurovascular Embolization3 recalls3 reports
- POD RBYPOD6-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION148 reports
- POD RBYPODJ30-APenumbra, Inc. · DEVICE, NEUROVASCULAR EMBOLIZATION132 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page