Medline PAIN8017Recalls & reported problems
Medline Industries, Inc. · NEEDLE, QUINCKE, 22GX3.5" · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10884389622261), received between Apr 14, 2026 and Apr 14, 2026 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Difficult to Open or Remove Packaging Material” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Open or Remove Packaging Material2
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 14, 2026Difficult to Open or Remove Packaging Material
THE PACKAGE TEARS ABOUT HALFWAY MAKING IT HARD TO SLIDE THE NEEDLE OUT OR IT CONTAMINATES BY FLIPPING OUT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24880306 ↗MalfunctionApr 14, 2026Difficult to Open or Remove Packaging Material
THE PACKAGE TEARS ABOUT HALFWAY MAKING IT HARD TO SLIDE THE NEEDLE OUT OR IT CONTAMINATES BY FLIPPING OUT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24880208 ↗
FDA clearance and classification
The FDA regulates product code BSP (needle, conduction, anesthetic (w/wo introducer)) under 21 CFR 868.5150 as a Class II device. 21 CFR 868.5150 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Medline PAIN8017
Has the Medline PAIN8017 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10884389622261), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Medline PAIN8017?
The FDA's MAUDE database lists 2 adverse event reports for this device, received on Apr 14, 2026. In those reports, the most common specific device problem is “Difficult to Open or Remove Packaging Material” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Medline PAIN8017?
None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Medline PAIN8017, and is it still sold?
The FDA's device database lists Medline Industries, Inc. as the company responsible for it (brand Medline, model PAIN8017). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER) devices
- ARROW IPN922632Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)2 recalls0 reports
- ARROW IPN922605Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922603Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922604Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922631Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN923597Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- 22G 1 1/2IN Regional Block Needle 408348Becton, Dickinson And Company · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- BD QUINCKE Spinal Needles 405180Becton, Dickinson And Company · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)23 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page