Skip to content

Dover 8887605205Recalls & reported problems

Cardinal Health, Inc. · 100% Silicone Foley Catheter,5 mL, 2-Way · Class 2

All models of Dover (90)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10884521016798), received between Sep 4, 2024 and Sep 4, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Obstruction of Flow” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Obstruction of Flow1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 4, 2024Obstruction of Flow; Obstruction of Flow

    PER CUSTOMER, HE WAS VERY UNSATISFIED WITH THE CATHETERS HE HAD PURCHASED, HE NORMALLY USES THOSE, AND EVERYTHING WAS FINE. THIS TIME HE SAID, HE WAS HAVING AN ISSUE WITH THE FLOW, AND HE ENDED UP IN THE HOSPITAL. ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER AND STATED THAT THE URINE FLOW WOULD NOT FLOW INTO THE BAG, IT WOULD BYPASS THE CATHETER. THERE WAS NO MEDICAL INTERVENTION OR TREATMENT REQUIRED AS THE RESULT OF THE REPORTED INCIDENT. ON (B)(6) 2024, ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER AND STATED THAT THE PATIENT WENT TO EMERGENCY ONLY TO HAVE THE CATHETER CHANGED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20135053 ↗

Other Catheter, Retention Type, Balloon devices

All Catheter, Retention Type, Balloon devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page