Argyle 8888561050Recalls & reported problems
Cardinal Health, Inc. · Trocar Catheter,Sharp Tip · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10884521029293), received between Feb 17, 2020 and Aug 9, 2024 — classified as 4 injuries, 1 malfunction.
The most frequently reported specific device problem is “Material Twisted/Bent” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Material Twisted/Bent3
- Detachment of Device or Device Component2
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Foreign Body In Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryAug 9, 2024Material Twisted/Bent; Material Twisted/Bent
THE CUSTOMER REPORTED THAT DURING (B)(6) 2024, THE THORACIC CATHETER WAS KINKED AT THE POINT OF ENTRANCE, OR WAS KINKED INTRATHORACIC, AND WAS NOT FUNCTIONAL. THE PROCEDURE PERFORMED WAS A THORACIC PROCEDURE. THE PATIENT IS SAFE, BUT HOSPITALIZATION WAS PROLONGED. ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER AND STATED THAT AT THE SECOND POSTOPERATIVE DAY, THE CHEST TUBE WAS SERIOUSLY KINKED AT THE POINT OF ENTRANCE. PER CUSTOMER, THE PATIENT WAS ALREADY HOSPITALIZED, AND THE HOSPITALIZATION WAS PROLONGED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19952392 ↗InjuryAug 9, 2024Material Twisted/Bent; Material Twisted/Bent
THE CUSTOMER REPORTED THAT DURING (B)(6) 2024, THE THORACIC CATHETER WAS KINKED AT THE POINT OF ENTRANCE, OR WAS KINKED INTRATHORACIC, AND WAS NOT FUNCTIONAL. THE PROCEDURE PERFORMED WAS A THORACIC PROCEDURE. THE PATIENT IS SAFE, BUT HOSPITALIZATION WAS PROLONGED. ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER AND STATED THAT AT THE SECOND POSTOPERATIVE DAY, THE CHEST TUBE WAS SERIOUSLY KINKED AT THE POINT OF ENTRANCE. PER CUSTOMER, THE PATIENT WAS ALREADY HOSPITALIZED, AND THE HOSPITALIZATION WAS PROLONGED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19951958 ↗InjuryAug 9, 2024Material Twisted/Bent; Material Twisted/Bent
THE CUSTOMER REPORTED THAT DURING THE MONTH OF (B)(6) 2024, THE THORACIC CATHETER WAS KINKED AT THE POINT OF ENTRANCE, OR WAS KINKED INTRATHORACIC, AND WAS NOT FUNCTIONAL. THE PATIENT IS SAFE, BUT HOSPITALIZATION WAS PROLONGED. ADDITIONAL INFORMATION WAS RECEIVED FROM THE CUSTOMER AND STATED THAT AT THE SECOND POSTOPERATIVE DAY, THE CHEST TUBE WAS SERIOUSLY KINKED AT THE POINT OF ENTRANCE. PER CUSTOMER, THE PATIENT WAS ALREADY HOSPITALIZED, AND THE HOSPITALIZATION WAS PROLONGED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19951680 ↗MalfunctionDec 27, 2023Detachment of Device or Device Component; Detachment of Device or Device Component
THE CUSTOMER REPORTED THE BLUE HANDLE OF THE TROCAR HAS BROKEN OFF THREE TIMES IN A ROW. NO PATIENT WAS HARMED
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18397915 ↗InjuryFeb 17, 2020Detachment of Device or Device Component; Detachment of Device or Device Component
THE CUSTOMER REPORTED THE TIP OF THE DEVICE REMAINED IN THE CHEST OF THE PATIENT. ADDITIONAL INFORMATION WAS RECEIVED STATING THAT THE TROCAR WAS REMOVED FROM THE PATIENT ENDOSCOPICALLY BEFORE THE START OF THE OPERATION AND THE PATIENT WAS FINE.
Patient problems: Foreign Body In Patient
MAUDE report 9717915 ↗
Other Trocar devices
- BRK™ G407208St. Jude Medical Cardiovascular Division · Trocar3 deaths75 reports
- BRK™ 407200St. Jude Medical Cardiovascular Division · Trocar4 deaths71 reports
- NA EP003994SMedtronic, Inc. · Trocar60 reports
- Cook G02364Cook Incorporated · Trocar1 recall5 reports
- HeartSpan® 00884450489345Merit Medical Systems, Inc. · Trocar1 recall1 death2 reports
- Cook G01377Cook Incorporated · Trocar1 recall2 reports
- HeartSpan® 00884450489369Merit Medical Systems, Inc. · Trocar1 recall0 reports
- Endrys G19261Cook Incorporated · Trocar1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page