Shiley 6.5PELF (UDI 10884521103436)Recalls & reported problems
Covidien LP · Pediatric Tracheostomy Tube Long, Cuffless · Class 2
All models of Shiley (387)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10884521103436), received between Apr 13, 2023 and Jun 16, 2023 — classified as 2 injuries, 1 malfunction.
The most frequently reported specific device problem is “Patient Device Interaction Problem” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K122531, K182861); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Patient Device Interaction Problem2
- Appropriate Device Problem Term/Code Not Available1
Patient problems
- Skin Inflammation/ Irritation3
- Discomfort2
- Inflammation2
- Swelling/ Edema2
- Unintended Extubation2
- Hypersensitivity/Allergic reaction1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 16, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
ACCORDING TO THE REPORTER, THE PATIENT HAD SKIN REDNESS AND SWELLING AFTER USING THE PELF TRACH CANNULA. THE TRACH CANNULA WAS TRIED SEVERAL TIMES, BUT THE ISSUE STILL PERSISTS. THE PATIENT RETURNED TO USING THE OLD PDL TRACH CANNULA.
Patient problems: Discomfort; Inflammation; Skin Inflammation/ Irritation; Swelling/ Edema; Unintended Extubation
MAUDE report 17148326 ↗InjuryJun 15, 2023Patient Device Interaction Problem; Patient Device Interaction Problem
ACCORDING TO THE REPORTER, THE PATIENT HAD SKIN REDNESS AND SWELLING AFTER USING THE PELF TRACH CANNULA. THE TRACH CANNULA WAS TRIED SEVERAL TIMES, BUT THE ISSUE STILL PERSISTED. THE PATIENT RETURNED TO USING THE OLD PDL TRACH CANNULA.
Patient problems: Discomfort; Inflammation; Skin Inflammation/ Irritation; Swelling/ Edema; Unintended Extubation
MAUDE report 17134292 ↗InjuryApr 13, 2023Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available
ACCORDING TO THE REPORTER, THE PATIENT HAD AN ALLERGIC REACTION TO SILICONE WITH A NEWLY PLACED TRACH DESPITE USING THE SAME CUSTOM TRACH MADE OF POLYVINYL CHLORIDE (PVC) FOR A LONG TIME.
Patient problems: Hypersensitivity/Allergic reaction; Skin Inflammation/ Irritation
MAUDE report 16731612 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K122531, K182861. One submission often covers many models, so check the product and lot details in each record.
- Z-1951-2015 · May 8, 2015 · TerminatedShiley Neonatal, Pediatric and Long Pediatric Tracheostomy Tube with TaperGuard Cuff. Intended for use in providing tracheal access for airway managements.
Other Tube tracheostomy and tube cuff devices
- Shiley 8CN85HCovidien LP · Tube tracheostomy and tube cuff1 recall2 deaths354 reports
- Shiley 6CN75HCovidien LP · Tube tracheostomy and tube cuff1 recall3 deaths240 reports
- Shiley 7CN80RCovidien LP · Tube tracheostomy and tube cuff2 recalls148 reports
- Bivona 67PFSS35Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall166 reports
- Bivona 670180Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall140 reports
- Bivona 670170Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall10 deaths132 reports
- Shiley 6CN75RCovidien LP · Tube tracheostomy and tube cuff1 recall1 death121 reports
- Bivona 67PFSS40Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall115 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page