Nellcor GR101704Recalls & reported problems

Covidien LP · Bedside Respiratory Patient Monitoring System · Class 2

All models of Nellcor (64)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10884521138681), received between Apr 20, 2018 and Jan 30, 2026 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Image Display Error/Artifact” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Image Display Error/Artifact2
  • Device Alarm System1
  • Failure of Device to Self-Test1
  • Failure to Power Up1
  • High Readings1
  • Incorrect Measurement1
  • Loss of Data1
  • Noise, Audible1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • No Consequences Or Impact To Patient1
  • No Patient Involvement1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJan 30, 2026Incorrect Measurement; Loss of Data

    IT WAS REPORTED THAT DURING PREPARATION FOR A PROCEDURE, THE DEVICE EXHIBITED INTERMITTENT READING DROP AND THE INABILITY TO ERASE TREND DATA. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24225705 ↗
  • MalfunctionNov 5, 2025Device Alarm System; Image Display Error/Artifact; Failure of Device to Self-Test; Device Alarm System; Image Display Error/Artifact; Failure of Device to Self-Test

    IT WAS REPORTED THAT A NURSE CALL ERROR OCCURRED AND THE DEVICE FAILED THE INITIAL POWER ON SELF TEST (POST). ADDITIONALLY, THE ALARM DID NOT FUNCTION BUT ALARMED WHEN ERROR CODE 11 COMING UP THAT STATED, "UNIT FAIL TO FINISH POST". THE MONITOR WAS POWER CYCLED AS A TROUBLESHOOTING STEP. THERE WAS NO PATIENT INVOLVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23482854 ↗
  • MalfunctionJun 16, 2021Failure to Power Up; Temperature Problem; Failure to Power Up; Temperature Problem

    ACCORDING TO THE REPORTER, THE UNIT WOULD TURN ON, THE POWER /SUPPLY/ADAPTOR OVERHEATED AND STARTED SMOKING. IT WAS INDICATED THAT THE POWER SUPPLY WAS SWAPPED, CHECKED FUSES AND POWER CYCLED THE UNIT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12008493 ↗
  • MalfunctionFeb 24, 2020High Readings; High Readings

    ACCORDING TO THE REPORTER, DURING USE, THE UNIT HAD A VERY HIGH READING. IT WAS STATED THAT THE PULSE READING WAS 187. THERE WAS NO PATIENT HARM.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 9747135 ↗
  • MalfunctionApr 20, 2018Image Display Error/Artifact; Noise, Audible; Image Display Error/Artifact; Noise, Audible

    ACCORDING TO THE REPORTER, THE DEVICE HAD A TASK 1 SPEAKER FAILURE UPON POWER ON AND NO AUDIBLE ALARM. THE CUSTOMER INDICATED THAT THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 7449000 ↗