Palindrome 8888145045CPRecalls & reported problems
Mozarc Medical US LLC · Precision H Chronic Catheter Kit,Symmetrical Tip, Heparin Coating and Tal VenaTrac Stylet,14.5 Fr/Ch (4.8 mm) x 28 cm · Class 2 · Implant
All models of Palindrome (133)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10884521158108), received between Mar 17, 2021 and Aug 23, 2022 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Break” (1 report).
1 FDA recall record name this device's identifier, 1 still open.
48 other recalls cover devices cleared under the same FDA submission (K123196); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Recalls naming this device
- Jun 8, 2022Class IOpen, Classified
There is a potential leaking condition within the hub of specific chronic dialysis catheters, due to an inter-lumen void in the hub component, which may result in unanticipated fluid return during use.
Z-1313-2022 · Root cause: Process control · Recall details · FDA record ↗
Most reported problems
Device problems
- Break1
- Detachment of Device or Device Component1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 23, 2022Break; Break
ACCORDING TO THE REPORTER, BEFORE DIALYSIS DURING TEGO CHANGE, IT WAS NOTED THAT THE CATHETER HAD CRACKED AT THE LUER ADAPTER CONNECTOR (BOTH VENOUS: BLUE, ARTERIAL: RED). IT WAS STATED THAT THE CATHETER HAS BEEN IN PLACE FOR SEVEN MONTHS. THERE WAS NO LEAK, THERE WAS NOTHING UNUSUAL OBSERVED ON THE DEVICE BEFORE USE, THE DEVICE WAS FLUSHED PRIOR TO USE AND EVERYTHING WENT NORMALLY. THE CLEANING AGENT USED ON THE DEVICE IS OCTENISEPT, OCTENISEPT WAS ALSO THE CLEANING AGENT TYPICALLY USED TO CLEAN THE ADAPTERS, AND THE CLEANING AGENT EXPOSURE TIME WAS ONE MINUTE (WHETHER IT ALWAYS DRIED IN ANY CASE WAS UNKNOWN) BEFORE APPLYING THE OINTMENT TO THE AREA. THE METHOD USED TO TIGHTEN THE ADAPTERS WAS HAND-HELD, NO OTHER PRODUCT WAS USED ON THE DEVICE, NO EXCESSIVE FORCE WAS USED ON THE DEVICE, AND THE CATHETER CANNOT BE REPAIRED BECAUSE THERE WAS NO REPAIR KIT AVAILABLE. IT WAS STATED THAT THE CORRECTIVE ACTION WAS POWERED BY TEGO (TEGO WAS UTILIZED) AND THE PROCEDURE WAS CONTINUED AND COMPLETED AFTER THE CORRECTIVE ACTION WAS DONE. INTERVENTION/TREATMENT WAS NOT REQUIRED DUE TO ADAPTER ISSUE. THERE WAS NO PATIENT SYMPTOMS OR COMPLICATIONS ASSOCIATED WITH THIS EVENT. THERE WAS NO BLOOD L
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 15278838 ↗MalfunctionMar 17, 2021Detachment of Device or Device Component; Detachment of Device or Device Component
ACCORDING TO THE REPORTER, ON FLUSHING AT THE END OF A TREATMENT, THE LINE FELL APART FROM THE TRIANGLE PLASTIC THAT HAD THE HOLES FOR ANCHORING STITCHES. IT SNAPPED ON THE ARTERIAL LUMEN SIDE. THE CATHETER WAS NOT REPAIRED. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11504990 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K123196. One submission often covers many models, so check the product and lot details in each record.
- Z-1887-2025 · Apr 23, 2025 · Open, ClassifiedPalindrome Precision SI Chronic Hemodialysis Catheter Sport Pack. Radiopaque urethane catheter.
- Z-1885-2025 · Apr 23, 2025 · Open, ClassifiedPalindrome Precision Chronic Hemodialysis Catheter Sport Pack. Radiopaque urethane catheter.
- Z-1886-2025 · Apr 23, 2025 · Open, ClassifiedPalindrome Precision HSI Chronic Hemodialysis Catheter Sport Pack. Radiopaque urethane catheter.
- Z-1888-2025 · Apr 23, 2025 · Open, ClassifiedPalindrome Precision H Chronic Hemodialysis Catheter Sport Pack. Radiopaque urethane catheter.
- Z-1889-2025 · Apr 23, 2025 · Open, ClassifiedMAHURKAR Chronic Hemodialysis Catheter Sport Pack. Radiopaque urethane catheter.
- Z-1635-2024 · Mar 15, 2024 · Open, ClassifiedPalindrome Precision H Chronic Catheter Kit 14.5 Fr/Ch (4.8mm) x 23 cm (Symmetrical Tip, Heparin Coating and Tal VenaTrac Stylet- Intended for acute and chronic hemodialysis, aph
- Z-1634-2024 · Mar 15, 2024 · Open, ClassifiedPalindrome Precision HSI Chronic Catheter Sport Pack 14.5 Fr/Ch (4.8mm) x 19 cm (Symmetrical Tip, Heparin Coating, Silver Ion Sleeve and Tal VenaTrac Stylet- Intended for acute a
- Z-1315-2022 · Jun 8, 2022 · Open, ClassifiedPalindrome Precision HSI Chronic Catheter, Sterile, Single Use, Rx Only. For acute and chronic hemodialysis, apheresis, and infusion.
- Z-1312-2022 · Jun 8, 2022 · Open, ClassifiedPalindrome Precision Chronic Catheter, Sterile, Single Use, Rx Only. For vascular access for acute and chronic hemodialysis, apheresis, and infusion.
- Z-1314-2022 · Jun 8, 2022 · Open, ClassifiedPalindrome Precision SI Chronic Catheter, Sterile, Single Use, Rx Only. For vascular access for acute and chronic hemodialysis, apheresis, and infusion.
- Z-2372-2021 · May 28, 2021 · Open, ClassifiedPalindrome Precision RT Chronic Catheter Kit Symmetrical Tip, Reverse-Tunneled 15 Fr/Ch (5.0 mm) x 28 cm, Item Code 8888541028P
- Z-2373-2021 · May 28, 2021 · Open, ClassifiedPalindrome Precision RT Chronic Catheter Kit Symmetrical Tip, Reverse-Tunneled 15 Fr/Ch (5.0 mm) x 33 cm, Item Code 8888541033P
- Z-2375-2021 · May 28, 2021 · Open, ClassifiedPalindrome Precision RT Chronic Catheter Kit Symmetrical Tip, Reverse-Tunneled 15 Fr/Ch (5.0 mm) x 55 cm, Item Code 8888541055P
- Z-2371-2021 · May 28, 2021 · Open, ClassifiedPalindrome Precision RT Chronic Catheter Kit Symmetrical Tip, Reverse-Tunneled 15 Fr/Ch (5.0 mm) x 23 cm, Item Code 8888541023P
- Z-2374-2021 · May 28, 2021 · Open, ClassifiedPalindrome Precision RT Chronic Catheter Kit Symmetrical Tip, Reverse-Tunneled 15 Fr/Ch (5.0 mm) x 44 cm, Item Code 8888541044P
…and 33 more.
Other Catheter, hemodialysis, implanted, coated devices
- Palindrome 8888145044CPMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls2 deaths30 reports
- Palindrome 8888123405PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls2 reports
- Palindrome 8888119365PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls2 reports
- Palindrome 8888133505PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls1 report
- Palindrome 8888128461PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls0 reports
- Palindrome 8888128455PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls0 reports
- Palindrome 8888119371PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls0 reports
- Palindrome 8888123411PMozarc Medical US LLC · Catheter, hemodialysis, implanted, coated2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page