Shiley 8CN85ERRecalls & reported problems

Covidien LP · Adult Flexible Evac Tracheostomy Tube with TaperGuard Cuff Reusable Inner Cannula · Class 2

All models of Shiley (387)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
16
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 16 adverse event reports that list this exact device (DI 10884521726307), received between Jan 31, 2022 and Jun 5, 2026 — classified as 1 injury, 15 malfunctions.

The most frequently reported specific device problem is “Gas/Air Leak” (11 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 2 reportsJul 2024: 0 reportsAug 2024: 4 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 1 reportsDec 2024: 0 reportsJan 2025: 1 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 1 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 2 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 1 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Gas/Air Leak11
  • Use of Device Problem4
  • Appropriate Device Problem Term/Code Not Available3
  • Defective Component2
  • Human-Device Interface Problem1

Patient problems

  • Unintended Extubation11
  • No Clinical Signs, Symptoms or Conditions4
  • Discomfort1
  • Low Oxygen Saturation1
  • Pain1

Recent adverse event reports

The 16 most recent of 16 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 5, 2026Use of Device Problem

    IT WAS REPORTED THAT PRIOR TO USE ON A PATIENT, THE TRACHEOSTOMY TUBE'S CUFF INTEGRITY TEST WAS PERFORMED AND FAILURE WAS OBSERVED WITH A HOLE AND LEAK IN THE CUFF. ANOTHER UNIT WAS USED AND THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25417448 ↗
  • MalfunctionMar 2, 2026Use of Device Problem; Gas/Air Leak

    IT WAS REPORTED THAT INTRA-OPERATIVELY, EVEN THE TRACH TUBE'S CUFF WAS CHECKED BEFORE PLACEMENT, AFTER INTUBATION THE CUFF STARTED TO LOOSE PRESSURE AND FOUND RUPTURED. THE TUBE WAS REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 24484889 ↗
  • MalfunctionFeb 17, 2026Gas/Air Leak

    IT WAS REPORTED THAT THE TRACHEOSTOMY TUBE EXPERIENCED A A LEAKING CUFF DURING USE. THE ISSUE TOOK PLACE IN A HOSPITAL SETTING. THE TUBE WAS REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 24372889 ↗
  • MalfunctionFeb 17, 2026Gas/Air Leak

    IT WAS REPORTED THAT THE TRACHEOSTOMY TUBE EXPERIENCED A A LEAKING CUFF DURING USE. THE ISSUE TOOK PLACE IN A HOSPITAL SETTING. THE TUBE WAS REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 24372859 ↗
  • MalfunctionApr 1, 2025Defective Component; Gas/Air Leak; Defective Component; Gas/Air Leak

    IT WAS REPORTED THAT A PATIENT WITH A TRACHEOSTOMY IN PLACE EXPERIENCED ISSUES WITH A TRACHEOSTOMY TUBE. THE CUFF OF THE TRACHEOSTOMY TUBE HAD A HOLE AND DEFLATED, LEADING TO A SECOND TRACHEAL LEAK WITHIN LESS THAN 24 HOURS FOR THE SAME PATIENT. THE TUBE WAS REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 21738585 ↗
  • MalfunctionJan 3, 2025Gas/Air Leak; Human-Device Interface Problem; Gas/Air Leak; Human-Device Interface Problem

    ACCORDING TO THE REPORTER, THE CUFF OF THE TWO TRACHEOSTOMY TUBES DID NOT HOLD PRESSURE AND HAD BEEN CONSISTENTLY LEAKING. THE PRESSURE WAS SET AND MAINTAINED AT A PRESSURE OF 20 TO 30 CMH2O, BUT THE PRESSURE WAS DOWN TO BETWEEN 10 AND 20 WITHIN 24 HOURS, SOMETIMES LESS THAN 8 HOURS. THERE WAS NO REPORTED PATIENT OUTCOME.

    Patient problems: Discomfort; Pain

    MAUDE report 21064616 ↗
  • MalfunctionNov 13, 2024Gas/Air Leak; Gas/Air Leak

    ACCORDING TO THE REPORTER, DURING USE, THE TRACHEOSTOMY TUBE'S CUFF WAS FOUND LEAKING. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20674803 ↗
  • MalfunctionSep 10, 2024Defective Component; Gas/Air Leak; Defective Component; Gas/Air Leak

    ACCORDING TO THE REPORTER, THE CUFF OF THE TRACHEOSTOMY TUBE COULD NOT SEAL DUE TO A LEAK AFTER ONE TO TWO DAYS OF INSERTION. THERE WAS NO PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20179899 ↗
  • MalfunctionAug 9, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    ACCORDING TO THE REPORTER, DURING USE, THERE WERE TRACHEOSTOMY TUBES THAT HAD SECRETIONS LEFT IN THE SUBGLOTTIC LINES. THE REPLACEMENT OF THE TUBE WAS DONE.

    Patient problems: Unintended Extubation

    MAUDE report 19953570 ↗
  • MalfunctionAug 7, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    ACCORDING TO THE REPORTER, DURING USE, THE TRACHEOSTOMY TUBE HAD SECRETION LEFT IN THE SUBGLOTTIC LINES. REPLACEMENT OF THE TUBE WAS DONE.

    Patient problems: Unintended Extubation

    MAUDE report 19929239 ↗
  • MalfunctionAug 7, 2024Appropriate Device Problem Term/Code Not Available; Appropriate Device Problem Term/Code Not Available

    ACCORDING TO THE REPORTER, DURING USE, THERE WERE TRACHEOSTOMY TUBES THAT HAD SECRETION LEFT IN THE SUBGLOTTIC LINES. REPLACEMENT OF THE TUBE WAS DONE.

    Patient problems: Unintended Extubation

    MAUDE report 19929237 ↗
  • MalfunctionAug 6, 2024Use of Device Problem; Use of Device Problem

    ACCORDING TO THE REPORTER, DURING INSPECTION, THE TRACHEOSTOMY TUBE'S CUFF WAS DEFLATING. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19917124 ↗
  • MalfunctionJun 29, 2024Gas/Air Leak; Gas/Air Leak

    ACCORDING TO THE REPORTER, DURING USE, THE PATIENT HAD BEEN INTUBATED FOR SEVERAL DAYS BEFORE GOING TO THE SUBGLOTTIC SECRETION UNIT. DURING THE CANNULA CHANGE, THERE WAS A SECRETION LEFT IN THE EVAC CANNULA AND SUCTION LINE AS SHOWN IN THE ATTACHED PHOTO. REPLACEMENT OF THE TUBE WAS DONE.

    Patient problems: Unintended Extubation

    MAUDE report 19640438 ↗
  • MalfunctionJun 8, 2024Gas/Air Leak; Gas/Air Leak

    ACCORDING TO THE REPORTER, BOTH TRACHEOSTOMY TUBES' CUFFS HAD A LEAK DURING PATIENT USAGE. THE TUBES WERE REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 19493308 ↗
  • InjuryMar 15, 2023Gas/Air Leak; Gas/Air Leak

    ACCORDING TO THE REPORTER, THE PATIENT DESATURATED DUE TO CUFF LEAK DURING THE PROCEDURE. THE TUBE WAS REPLACED.

    Patient problems: Low Oxygen Saturation; Unintended Extubation

    MAUDE report 16546050 ↗
  • MalfunctionJan 31, 2022Use of Device Problem; Gas/Air Leak; Use of Device Problem; Gas/Air Leak

    ACCORDING TO THE REPORTER, DURING ROUTINE CHECK ON THE PATIENT, THE CUFF OF THE DEVICE WAS FOUND DEFLATED. ATTEMPTED TO RE-INFLATE THE CUFF BUT HAD FAILED. THE PATIENT HAD A REPLACEMENT OF THE TUBE. THE EXTUBATED DEVICE HAD CONFIRMED A LEAK ON THE CUFF.

    Patient problems: Unintended Extubation

    MAUDE report 13392598 ↗

Other Tube tracheostomy and tube cuff devices

All Tube tracheostomy and tube cuff devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page