Shiley 86232 (UDI 10884521797246)Recalls & reported problems

Covidien LP · Oral/Nasal Tracheal Tube Cuffless Non DEHP, Murphy Eye · Class 2

All models of Shiley (387)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10884521797246), received between May 9, 2022 and May 22, 2025 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Disconnection” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Disconnection2
  • Obstruction of Flow2
  • Component Missing1
  • Manufacturing, Packaging or Shipping Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2
  • Unintended Extubation2
  • Low Oxygen Saturation1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 22, 2025Obstruction of Flow; Obstruction of Flow

    IT WAS REPORTED THAT WHEN THE PATIENT WAS INTUBATED AND A SUCTION CATHETER WAS INSERTED INTO THE LUMEN OF THE ENDOTRACHEAL TUBE, THE SUCTION TUBE COULD NOT BE INSERTED. UNDER THE ASSUMPTION THAT THE LUMEN WAS TOO NARROW, THE SUCTION TUBE WAS REINTUBATED USING A LARGER SIZE OF 2.5, AND THE TUBE HAD TO BE REMOVED, AND IT WAS DISCOVERED THAT A FOREIGN OBJECT HAD ENTERED THE LUMEN OF THE TUBE. THE TUBE WAS REPLACED.

    Patient problems: Unintended Extubation

    MAUDE report 22073186 ↗
  • MalfunctionMay 1, 2024Disconnection; Disconnection

    ACCORDING TO THE REPORTER, THE ENDOTRACHEAL TUBE'S CONNECTOR WAS SEPARATED FROM THE TRANSPARENT TUBE BODY AND COULD NOT BE CONNECTED TIGHTLY BEFORE USE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19221716 ↗
  • InjuryApr 11, 2024Obstruction of Flow; Obstruction of Flow

    ACCORDING TO THE REPORTER, THERE WAS AN UNPLANNED DELIVERY OF A PRE-TERM INFANT WITH NO KNOWN TERM AT THE TIME IN A MOBILE HOSPITAL UNIT. THE PATIENT HAD A CARDIOPULMONARY ARREST AND WAS RESUSCITATED BY THE ¿FIRE¿ TEAM FOR 15 MINUTES UPON ARRIVAL ON SITE. THE PATIENT WAS PLACED IN THE FACILITY TRUCK TO CONTINUE RESUSCITATION. THE RESUSCITATION CONSISTED OF WARMING UP, CONTINUING THE CARDIAC MASSAGE, AND INTUBATING TO ALLOW BREATHING AT THE BAVU AND TO DELIVER CUROSURF SURFACTANT/DRUG, WHICH WAS NOTED AS THE MOST EFFECTIVE TREATMENT IN EXTREME PREMATURE INFANTS. THE INTUBATION THROUGH THE 2.5 TUBE COULD NOT PASS THE VOCAL CORDS, SO A 2.0 TUBE WAS USED. AS THE 2.0 TUBE DID NOT HAVE A LATERAL CHANNEL FOR INTRATRACHEAL THERAPY DELIVERY (OR SCREW ¿COBB¿), IT WAS NECESSARY TO PASS THE THERAPY THROUGH THE TUBE. THE DOCTOR PUT THE SYRINGE TIP DIRECTLY INTO THE TUBE TO PUSH THE SURFACTANT FOR FASTER DELIVERY COMPARED TO DELIVERY BY PUTTING A SUCTION PROBE IN THE TUBE AND INJECTING INTO THE SUCTION PROBE. HOWEVER, BY REMOVING THE TIP CONNECTED TO THE BAVU, THE SOLID PART OF THE TIP BECAME SEVERED AND REMAINED STUCK IN THE TUBING. THIS MADE IT IMPOSSIBLE TO ADMINISTER THE CUROSURF DRUG AND VE

    Patient problems: Low Oxygen Saturation; Unintended Extubation

    MAUDE report 19093972 ↗
  • MalfunctionMay 9, 2022Disconnection; Component Missing; Manufacturing, Packaging or Shipping Problem; Disconnection; Component Missing; Manufacturing, Packaging or Shipping Problem

    ACCORDING TO THE REPORTER, THE PRODUCT ISSUE WAS NOTED WHEN THE ETT WAS PULLED OUT OF THE AIRWAY BOX IN THE DELIVERY ROOM FOR PREPARATION IN CASE THE PATIENT NEEDED TO BE INTUBATED. THERE WAS ONE TUBE WITHOUT THE HUB ATTACHED. THERE WAS NO PATIENT INVOLVEMENT. MEDTRONIC'S INITIAL EVALUATION OF THE INCIDENT DEVICE FOUND A CONNECTOR SEPARATION ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14337229 ↗

Other Tube, tracheal (w/wo connector) devices

All Tube, tracheal (w/wo connector) devices →