DAR 444SP02012 (UDI 10884521822887)Recalls & reported problems
Covidien LP · Closed Suction System, Replaceable Catheter,Endotracheal Length,DETACH. DSE · Class 1
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 10884521822887), received between Sep 10, 2024 and Mar 12, 2026 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Gas/Air Leak” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Gas/Air Leak3
- Use of Device Problem2
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- Low Oxygen Saturation1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryMar 12, 2026Use of Device Problem
IT WAS REPORTED THAT DURING A ROUTINE SYSTEM CHANGE INVOLVING THE CLOSE SUCTION CIRCUIT, A PATIENT EXPERIENCED A DROP IN PERIPHERAL OXYGEN SATURATION DUE TO EXISTING SECRETIONS IN THE LUNGS. AN ATTEMPT WAS MADE TO SUCTION THE SECRETIONS ENDOTRACHEALLY, BUT SUCTION COULD NOT BE GENERATED BECAUSE THE BLUE SUCTION VALVE BUTTON WAS NOT FUNCTIONING. THE PERIPHERAL OXYGEN SATURATION CONTINUED TO FALL. PRE-OXYGENATION WAS PERFORMED, AND SECRETIONS WERE SUBSEQUENTLY REMOVED USING CONVENTIONAL STERILE SUCTIONING, AFTER WHICH OXYGEN SATURATION RETURNED TO NORMAL LEVELS.
Patient problems: Low Oxygen Saturation
MAUDE report 24583294 ↗MalfunctionJan 8, 2026Use of Device Problem
IT WAS REPORTED THAT THE BREATHING SUCTION SYSTEM HAD A LEAK OCCURRED DURING PRE-USAGE INSPECTION. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24007472 ↗MalfunctionNov 7, 2024Gas/Air Leak; Gas/Air Leak
ACCORDING TO THE REPORTER, DURING USE, THE BREATHING SYSTEM SUCTION HAD A LEAK. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20629462 ↗MalfunctionSep 23, 2024Gas/Air Leak; Gas/Air Leak
ACCORDING TO THE REPORTER, DURING USE, AN AIR LEAK WAS CONFIRMED FROM THE VENTILATOR WAVEFORM AND WAS DETECTED IN THE SERPENTINE TUBE PART OF DEVICE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20286443 ↗MalfunctionSep 10, 2024Gas/Air Leak; Gas/Air Leak
ACCORDING TO THE REPORTER, DURING USE, THE GAS FROM THE VENTILATOR WAS LEAKING FROM THE DEVICE. THERE WAS NO PATIENT INJURY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20180484 ↗
Other CATHETERS, SUCTION, TRACHEOBRONCHIAL devices
- Ballard* Closed Suction System 93826Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall70 reports
- Ballard* Closed Suction System 92431Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL78 reports
- Medline DYNCPDS14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall16 reports
- Ballard* Turbo-Cleaning Closed Suction System 98965Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall16 reports
- Ballard* Turbo-Cleaning Closed Suction System 98263Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall11 reports
- Ballard* Closed Suction System for Adults 98310Avanos Medical, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall1 death9 reports
- Medline DYNCPTP14TMedline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall6 reports
- Medline DYNCPTP14Medline Industries, Inc. · CATHETERS, SUCTION, TRACHEOBRONCHIAL1 recall4 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.