DARRecalls & reported problems across all models
Covidien LP · 35 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
3 open recalls name at least one DAR model. Check whether yours is affected in the recall details, and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 172
- Deaths reported
- 1
- Injuries reported
- 16
- Recalls
- 3
We found 35 models of DAR by Covidien LP in the FDA's device registry (GUDID). Together they are named in 172 adverse event reports in the FDA's MAUDE database, received between Nov 6, 2017 and Sep 28, 2026 — classified as 1 death, 16 injuries, 155 malfunctions.
The most frequently reported specific device problem is “Gas/Air Leak” (71 reports).
3 FDA recall records name at least one of these models by its device identifier, 3 still open.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
DAR recalls
FDA recall records that name at least one of these models by its device identifier, newest first. Each recall usually covers specific models or lots, so check the details.
- Apr 29, 2021Open, Classified
The company was notified by their supplier of sterilization services for airway products in Italy of potential deviations from validated parameters for ethylene oxide sterilization.
Z-1869-2021 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
- Apr 29, 2021Open, Classified
The company was notified by their supplier of sterilization services for airway products in Italy of potential deviations from validated parameters for ethylene oxide sterilization.
Z-1867-2021 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
- Apr 29, 2021Open, Classified
The company was notified by their supplier of sterilization services for airway products in Italy of potential deviations from validated parameters for ethylene oxide sterilization.
Z-1866-2021 · Root cause: Material/Component Contamination · Recall details · FDA record ↗
Most reported DAR problems
Device problems
- Gas/Air Leak71
- Use of Device Problem46
- Crack34
- Material Split, Cut or Torn29
- Connection Problem10
- Device Damaged Prior to Use4
- Filtration Problem3
- Appropriate Device Problem Term/Code Not Available2
Patient problems
- No Clinical Signs, Symptoms or Conditions139
- Insufficient Information16
- Low Oxygen Saturation12
- Hypoventilation4
- Hypoxia2
- Unspecified Tissue Injury2
- Hemorrhage/Blood Loss/Bleeding1
- No Consequences Or Impact To Patient1
DAR models
35 models, most reported first. Each model has its own page with its reports, recalls and device details.
- DAR 353S19046CONDENSER, HEAT AND MOISTURE (ARTIFICIAL NOSE)1 recall1 report
- DAR 350S19006Filter, bacterial, breathing-circuit1 recall1 report
- DAR 351/5979Filter, bacterial, breathing-circuit1 recall0 reports
- DAR 444SP02012CATHETERS, SUCTION, TRACHEOBRONCHIAL50 reports
- DAR 354/5876CONDENSER, HEAT AND MOISTURE (ARTIFICIAL NOSE)25 reports
- DAR 352/5877Filter, bacterial, breathing-circuit23 reports
- DAR 444SP02014CATHETERS, SUCTION, TRACHEOBRONCHIAL10 reports
- DAR 350/5879Filter, bacterial, breathing-circuit1 death8 reports
- DAR 350/5865ZFilter, bacterial, breathing-circuit7 reports
- DAR 5093600Filter, bacterial, breathing-circuit5 reports
- DAR 444SP02012CATHETERS, SUCTION, TRACHEOBRONCHIAL5 reports
- DAR 4-076408-00Filter, bacterial, breathing-circuit3 reports
- DAR 444SP02014CATHETERS, SUCTION, TRACHEOBRONCHIAL3 reports
- DAR 352/5877Filter, bacterial, breathing-circuit3 reports
- DAR 444SP02012CATHETERS, SUCTION, TRACHEOBRONCHIAL2 reports
- DAR 444SP02014CATHETERS, SUCTION, TRACHEOBRONCHIAL2 reports
- DAR 352/5855Filter, bacterial, breathing-circuit2 reports
- DAR 610U5257CONNECTOR, AIRWAY (EXTENSION)2 reports
- DAR 444SP02314CATHETERS, SUCTION, TRACHEOBRONCHIAL2 reports
- DAR 351/5856Filter, bacterial, breathing-circuit2 reports
- DAR 331/5661CONNECTOR, AIRWAY (EXTENSION)2 reports
- DAR 351/5410ZFilter, bacterial, breathing-circuit1 report
- DAR 111P1160Circuit, Breathing (W Connector, Adaptor, Y Piece)1 report
- DAR 444S02708CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444SP00412CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444S02605CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444SP02010CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444SP02114CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444SP02312CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444S02608CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 444S02708CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
- DAR 351U5979Filter, bacterial, breathing-circuit1 report
- DAR 352U5805Filter, bacterial, breathing-circuit1 report
- DAR 355U5430Filter, bacterial, breathing-circuit1 report
- DAR 444SP02114CATHETERS, SUCTION, TRACHEOBRONCHIAL1 report
Recent DAR adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionSep 28, 2026Break; Obstruction of Flow
Patient in CTICU "[cardio-thoracic intensive care unit]" underwent bedside percutaneous tracheostomy. The ventilator was plugged into bronch adapter (Covidien DAR connector, REF 610U5257, LOT 25G0004FAX, Exp 7/1/2030) during procedure. Once tracheostomy tube was inserted, we attempted to disconnect vent circuit from the bronch adapter, but the bronch adapter broke off into the vent circuit and could not be removed. Patient was bagged with BVM "[bag-valve-mask]" without any complication and RT "[respiratory therapist]" got new vent circuit. No harm met the patient, but this was a device failure causing obstruction of ventilator tubing.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50914753 ↗MalfunctionApr 9, 2026Use of Device Problem
IT WAS REPORTED THAT DURING PRE-USAGE INSPECTION, THE BREATHING SYSTEM CIRCUIT SET FAILED THE PERFORMED LEAK TEST. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24835131 ↗MalfunctionApr 9, 2026Use of Device Problem
IT WAS REPORTED THAT DURING PRE-USAGE INSPECTION, THE BREATHING SYSTEM CIRCUIT SET FAILED THE PERFORMED LEAK TEST. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24835093 ↗MalfunctionMar 31, 2026Gas/Air Leak
IT WAS REPORTED THAT THE NURSE ROUTINELY REPLACED THE BREATHING CIRCUIT AND VENTILATOR TUBING. ONE HOUR LATER, THE BEDSIDE NURSE DISCOVERED CONDENSATE LEAKING FROM THE CONNECTION BETWEEN THE BREATHING CIRCUIT AND THE ENDOTRACHEAL TUBE, INDICATING POOR SEALING AT THE INTERFACE. THE BREATHING CIRCUIT WAS IMMEDIATELY REPLACED. PATIENT OUTCOME WAS ASKED BUT UNKNOWN.
Patient problems: Insufficient Information
MAUDE report 24746261 ↗MalfunctionMar 17, 2026Crack
IT WAS REPORTED THAT DURING INSPECTION OF THE RECEIVED BREATHING SYSTEM FILTERS, SIX UNITS WERE FOUND CRACKED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24621626 ↗MalfunctionMar 17, 2026Crack
IT WAS REPORTED THAT DURING INSPECTION OF THE RECEIVED BREATHING SYSTEM FILTERS, SIX UNITS WERE FOUND CRACKED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24621588 ↗MalfunctionMar 17, 2026Crack
IT WAS REPORTED THAT DURING INSPECTION OF THE RECEIVED BREATHING SYSTEM FILTERS, SIX UNITS WERE FOUND CRACKED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24621562 ↗MalfunctionMar 17, 2026Crack
IT WAS REPORTED THAT DURING INSPECTION OF THE RECEIVED BREATHING SYSTEM FILTERS, SIX UNITS WERE FOUND CRACKED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24621514 ↗MalfunctionMar 17, 2026Crack
IT WAS REPORTED THAT DURING INSPECTION OF THE RECEIVED BREATHING SYSTEM FILTERS, SIX UNITS WERE FOUND CRACKED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24621471 ↗MalfunctionMar 17, 2026Crack
IT WAS REPORTED THAT DURING INSPECTION OF THE RECEIVED BREATHING SYSTEM FILTERS, SIX UNITS WERE FOUND CRACKED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24621417 ↗InjuryMar 12, 2026Use of Device Problem
IT WAS REPORTED THAT DURING A ROUTINE SYSTEM CHANGE INVOLVING THE CLOSE SUCTION CIRCUIT, A PATIENT EXPERIENCED A DROP IN PERIPHERAL OXYGEN SATURATION DUE TO EXISTING SECRETIONS IN THE LUNGS. AN ATTEMPT WAS MADE TO SUCTION THE SECRETIONS ENDOTRACHEALLY, BUT SUCTION COULD NOT BE GENERATED BECAUSE THE BLUE SUCTION VALVE BUTTON WAS NOT FUNCTIONING. THE PERIPHERAL OXYGEN SATURATION CONTINUED TO FALL. PRE-OXYGENATION WAS PERFORMED, AND SECRETIONS WERE SUBSEQUENTLY REMOVED USING CONVENTIONAL STERILE SUCTIONING, AFTER WHICH OXYGEN SATURATION RETURNED TO NORMAL LEVELS.
Patient problems: Low Oxygen Saturation
MAUDE report 24583294 ↗MalfunctionFeb 10, 2026Gas/Air Leak
IT WAS REPORTED THAT AN AIR LEAK OCCURRED INVOLVING A CIRCUIT, BREATHING AND FILTER, AND THE LOCATION WAS UNKNOWN PRIOR TO USE. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24309151 ↗MalfunctionJan 27, 2026Gas/Air Leak
IT WAS REPORTED THAT A N AIR LEAK WAS DETECTED WHEN THE CIRCUIT WAS CONNECTED TO THE VENTILATOR ALONG WITH THE FILTER AND ADAPTOR PRIOR TO USE. THE ISSUE WAS RESOLVED AFTER THE CIRCUIT REPLACED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24194046 ↗MalfunctionJan 27, 2026Gas/Air Leak
IT WAS REPORTED THAT A N AIR LEAK WAS DETECTED WHEN THE CIRCUIT WAS CONNECTED TO THE VENTILATOR ALONG WITH THE FILTER AND ADAPTOR PRIOR TO USE. THE ISSUE WAS RESOLVED AFTER THE CIRCUIT REPLACED. THERE WAS NO PATIENT INVOLVED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24193956 ↗MalfunctionJan 21, 2026Gas/Air Leak
IT WAS REPORTED THAT LEAKAGE OCCURRED ON THE WHITE ATTACHMENT PIECE TO THE ENDOTRACHEAL TUBE OF THE SUCTION CATHETER, AND NO AIR WAS ENTERING THE LUNGS. THE PROBLEM WAS SOLVED BY CHANGING THE SUCTION SYSTEM. THERE WAS NO PATIENT HARM.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24140301 ↗
Other Covidien LP products
- Endo GIA48 models · 26,277 reports · 8 recalls
- Endo GIA Ultra3 models · 15,650 reports
- Shiley387 models · 9,392 reports · 5 recalls
- Signia16 models · 8,201 reports · 6 recalls
- LigaSure32 models · 7,283 reports · 1 recall
- Tri-Staple 2.037 models · 4,892 reports · 2 recalls
- Polysorb291 models · 4,564 reports · 2 recalls
- EEA39 models · 4,432 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page