Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10884527005161), received between May 30, 2019 and Jul 19, 2021 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
- Fluid/Blood Leak1
Patient problems
- Foreign Body In Patient1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJul 19, 2021Break; Break
THE CUSTOMER REPORTED A UVC FRAGMENT WAS INCIDENTALLY IDENTIFIED IN THE NICU PATIENT¿S AORTA ON IMAGING. THE RN REMOVED THE CATHETER AND NOTED IT WAS NOT INTACT. THE MARKINGS INDICATED THERE WAS 15CM MISSING. THE UVC WAS INSERTED AT ANOTHER HOSPITAL. ADDITIONAL INFORMATION RECEIVED STATED, PER STAFF INTERVIEW, THE STANDARD PROCESS TO REMOVE A UVC IS TO CLIP THE SUTURE AND THEN PULL GENTLY AND SLOWLY ON THE CATHETER FOR REMOVAL. THE RN DIDN'T NOTICE ANYTHING UNUSUAL ABOUT REMOVING THE CATHETER FOLLOWING THIS PROCESS. THE PATIENT WAS TRANSFERRED TO AN OUT OF NETWORK FACILITY AND THE RETAINED ARTERIAL CATHETER WAS REMOVED BY THE IR TEAM. THERE WERE NO IDENTIFIED COMPLICATIONS CAUSED BY THE RETAINED ARTERIAL CATHETER.
Patient problems: Foreign Body In Patient
MAUDE report 12191994 ↗MalfunctionMay 30, 2019Fluid/Blood Leak; Fluid/Blood Leak
THE CUSTOMER REPORTED THE UMBILICAL ARTERY CATHETER WAS PLACED IN A ONE DAY OLD MALE PATIENT WEIGHING (B)(6) GRAMS. THE IVFS WERE ATTACHED AND TRANSDUCING APPROPRIATE WAVEFORM AND BP. LAB WAS DRAWN FROM UAC AT THE STOPCOCK CONNECTION WITHOUT INCIDENCE. THERE WAS GOOD BLOOD RETURN AND IT FLUSHED EASILY. APPROXIMATELY 20 MINUTES LATER, THE LINE BEGAN TO BACK UP BLOOD AND IT WAS NOTED THAT THERE WAS LEAKING FROM A CRACK IN THE LINE NEAR THE HUB. THE LINE WAS CLAMPED TO PREVENT BLOOD LOSS AND THE MEDICAL DOCTOR WAS NOTIFIED. THE CATHETER WAS REMOVED BY THE MEDICAL DOCTOR AND REPLACED WITH A NEW UMBILICAL CATHETER.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8655088 ↗
FDA clearance and classification
The FDA regulates product code FOS (catheter, umbilical artery) under 21 CFR 880.5200 as a Class II device. 21 CFR 880.5200 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Argyle 8888160432
Has the Argyle 8888160432 been recalled?
No FDA recall record in our data names this exact device identifier (DI 10884527005161), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Argyle 8888160432?
The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 30, 2019 and Jul 19, 2021. In those reports, the most common specific device problems are “Break” (1) and “Fluid/Blood Leak” (1); the most common patient problem is “Foreign Body In Patient” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Argyle 8888160432?
None of the reports are classified as deaths, 1 as an injury and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the Argyle 8888160432, and is it still sold?
The FDA's device database lists Cardinal Health 200, LLC as the company responsible for it (brand Argyle, model 8888160432). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other CATHETER, UMBILICAL ARTERY devices
- Argyle 8888160333Cardinal Health, Inc. · CATHETER, UMBILICAL ARTERY2 deaths66 reports
- Argyle 8888160333Cardinal Health 200, LLC · CATHETER, UMBILICAL ARTERY1 recall6 reports
- Argyle 8888160556Cardinal Health 200, LLC · CATHETER, UMBILICAL ARTERY1 recall1 report
- Argyle 8888160341Cardinal Health 200, LLC · CATHETER, UMBILICAL ARTERY1 recall1 report
- Argyle 8888160648Cardinal Health 200, LLC · CATHETER, UMBILICAL ARTERY1 recall0 reports
- Argyle 8888160119Cardinal Health 200, LLC · CATHETER, UMBILICAL ARTERY1 recall0 reports
- Argyle 8888160325Cardinal Health 200, LLC · CATHETER, UMBILICAL ARTERY1 recall0 reports
- Argyle 8888160341Cardinal Health, Inc. · CATHETER, UMBILICAL ARTERY36 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.