Alaris 10013890Recalls & reported problems

BD Switzerland Sàrl · Pump Infusion Set, Low Sorbing Tubing (PE Lined) 112 cm (44 in) · Class 2

All models of Alaris (85)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

2 open recalls name this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
8
Deaths reported
0
Injuries reported
0
Recalls naming it
2

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 10885403232268), received between Nov 7, 2018 and Jun 9, 2020 — classified as 8 malfunctions.

The most frequently reported specific device problem is “Fluid/Blood Leak” (4 reports).

2 FDA recall records name this device's identifier, 2 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Aug 19, 2026Class IOpen, Classified

    Due to discrepancies in specific attributes in the performance data for infusion sets, which may lead to inappropriate pump performance.

    Z-3080-2026 · Root cause: Device Design · Recall details · FDA record ↗

  2. Oct 11, 2023Class IIOpen, Classified

    Affected infusion sets labeled as free of DEHP actually do contain di(2-ethylhexyl) phthalate (DEHP).

    Z-0349-2024 · Root cause: Error in labeling · Recall details · FDA record ↗

Most reported problems

Device problems

  • Fluid/Blood Leak4
  • Break3
  • Crack1
  • Material Deformation1
  • Material Puncture/Hole1
  • Material Separation1
  • Tear, Rip or Hole in Device Packaging1

Patient problems

  • No Patient Involvement3
  • No Consequences Or Impact To Patient2
  • No Known Impact Or Consequence To Patient2
  • No Information1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 9, 2020Material Separation; Material Separation

    IT WAS REPORTED FROM THE FIRST HILL CAMPUS OF THE SWEDISH CANCER INSTITUTE TREATMENT CENTER THAT THE TUBING HAD SEPARATED FROM THE SAFETY CLAMP. THERE WERE NO ADVERSE EFFECTS CAUSED TO THE PATIENT FROM THE EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10136453 ↗
  • MalfunctionMay 12, 2020Fluid/Blood Leak; Tear, Rip or Hole in Device Packaging; Fluid/Blood Leak; Tear, Rip or Hole in Device Packaging

    IT WAS REPORTED THAT THE IV TUBING SET APPEARED TO HAVE MICRO HOLES WHERE FLUID SEEMED TO BE SEEPING FROM THE TUBING WHERE THE CARTRIDGE IS INSERTED INTO PUMP

    Patient problems: No Information

    MAUDE report 10046525 ↗
  • MalfunctionMay 5, 2020Material Puncture/Hole; Material Deformation; Material Puncture/Hole; Material Deformation

    IT WAS REPORTED THAT DURING AN INFUSION THE TUBING APPEARED TO HAVE MICRO HOLES WHERE THE FLUID APPEARED TO SEEP FROM THE TUBING WHERE THE CARTRIDGE IS INSERTED INTO THE PUMP. IT WAS REPORTED NO MEDICAL TREATMENT WAS REQUIRED AS A RESULT OF THE EVENT.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10026616 ↗
  • MalfunctionApr 29, 2020Break; Fluid/Blood Leak; Break; Fluid/Blood Leak

    IT WAS REPORTED THAT WHILE GOING TO HANG THE CHEMOTHERAPY INFUSION 1L NS BAG MIXED WITH CISPLATIN, CYTOXAN, AND VEPESID, THE PRIMARY TUBING SET SPIKE BROKE. THE CHEMOTHERAPY DRUG SPILLED INSIDE OF THE BAG IT WAS CARRIED IN, BUT DID NOT SPILL OUTSIDE OF THE CARRIER BAG. THIS OCCURRED AT INPATIENT ONCOLOGY. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10011280 ↗
  • MalfunctionApr 27, 2020Break; Break

    IT WAS REPORTED THAT WHILE PRIMING THE CHEMOTHERAPY INFUSION 1L NS BAG MIXED WITH CISPLATIN, CYTOXAN, AND VEPESID, THE PRIMARY TUBING SET SPIKE BROKE. IT WAS REPORTED THAT THIS OCCURRED TWICE ON UNKNOWN DATES, AT INPATIENT ONCOLOGY. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10000524 ↗
  • MalfunctionApr 27, 2020Break; Break

    IT WAS REPORTED THAT WHILE PRIMING THE CHEMOTHERAPY INFUSION 1L NS BAG MIXED WITH CISPLATIN, CYTOXAN, AND VEPESID, THE PRIMARY TUBING SET SPIKE BROKE. IT WAS REPORTED THAT THIS OCCURRED TWICE ON UNKNOWN DATES, AT INPATIENT ONCOLOGY. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Patient Involvement

    MAUDE report 10000522 ↗
  • MalfunctionJan 4, 2019Fluid/Blood Leak; Fluid/Blood Leak

    THE CUSTOMER REPORTED A TUBING LEAK. THERE WAS NO REPORT OF HARM. THE SPECIFIC EVENT DATE WAS NOT PROVIDED HOWEVER IT OCCURRED WITH THE LAST COUPLE OF YEARS.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8220042 ↗
  • MalfunctionNov 7, 2018Crack; Fluid/Blood Leak; Crack; Fluid/Blood Leak

    THE CUSTOMER REPORTED TUBING CRACKED AND LEAKED WHILE INFUSING CHEMO. THERE WAS NO REPORT OF PATIENT HARM.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8048442 ↗

FDA clearance and classification

The FDA regulates product code FPA (set, administration, intravascular) under 21 CFR 880.5440 as a Class II device. 21 CFR 880.5440 ↗

Devices of this type normally need 510(k) clearance before sale.

Common questions about the Alaris 10013890

Has the Alaris 10013890 been recalled?

Yes. 2 FDA recall records name this device's identifier: 2 still open. The most recent, Z-3080-2026 (Class I), began on Aug 19, 2026: Due to discrepancies in specific attributes in the performance data for infusion sets, which may lead to inappropriate pump performance. If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the Alaris 10013890?

The FDA's MAUDE database lists 8 adverse event reports for this device, received between Nov 7, 2018 and Jun 9, 2020. In those reports, the most common specific device problems are “Fluid/Blood Leak” (4), “Break” (3) and “Crack” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Alaris 10013890?

None of the reports are classified as deaths, 0 as injuries and 8 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the Alaris 10013890, and is it still sold?

The FDA's device database lists BD Switzerland Sàrl as the company responsible for it (brand Alaris, model 10013890). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Set, administration, intravascular devices

All Set, administration, intravascular devices →