Alaris, SmartSite 11059729Recalls & reported problems

BD Switzerland Sàrl · Pump Infusion Set, Back Check Valve, 4-Way Stopcock, 4 Y-Sites 329 cm (130 in) · Class 2

All models of Alaris, SmartSite (160)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 10885403232497), received between Nov 9, 2018 and Dec 31, 2019 — classified as 1 injury, 3 malfunctions.

The most frequently reported specific device problem is “Disconnection” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Disconnection2
  • Fluid/Blood Leak2
  • Device Difficult to Setup or Prepare1
  • Excess Flow or Over-Infusion1
  • Failure to Deliver1
  • Insufficient Flow or Under Infusion1

Patient problems

  • No Information2
  • Inadequate Pain Relief1
  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionDec 31, 2019Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    IT WAS REPORTED THAT THE MEDICATION WAS FLOWING FASTER THAN IT SHOULD INTO THE PATIENT'S IV TUBING. ADDITIONAL INFORMATION WAS REQUESTED, BUT WAS NOT RECEIVED.

    Patient problems: No Information

    MAUDE report 9536266 ↗
  • MalfunctionOct 22, 2019Device Difficult to Setup or Prepare; Insufficient Flow or Under Infusion; Failure to Deliver; Device Difficult to Setup or Prepare; Insufficient Flow or Under Infusion; Failure to Deliver

    IT WAS REPORTED THAT THE PHYSICIAN HAD DIFFICULTY ASSEMBLING THE ANESTHESIA SET DUE TO THE COMPONENTS WERE INCOMPATIBLE; "THE MALE LUER CONNECTOR AT THE END OF AN EXTENSION TUBE DID NOT OPEN THE VALVE ON THE FEMALE Y-PORT". THE CUSTOMER STATED THAT THE TRAUMA PATIENT HAD A DELAY IN CRITICAL MEDICATIONS DUE TO THE ISSUE HOWEVER THE STAFF WAS ABLE TO CONNECT THE SET AFTER FIXING THE ISSUE . IT WAS LATER REPORTED TURNS OUT TO BE A COMPATIBILITY ISSUE WITH ICU MEDICAL¿S MALE LUER LOCK BEING UNABLE TO ENGAGE THE SMART SITE Y-PORT ON BD¿S TUBING SETS.THE PHYSICIAN WAS ABLE TO QUICKLY DETERMINE THE INCOMPATIBILITY AND CHANGE THE METHOD OF DELIVERY.

    Patient problems: No Information

    MAUDE report 9221375 ↗
  • InjuryNov 15, 2018Disconnection; Fluid/Blood Leak; Disconnection; Fluid/Blood Leak

    THE CUSTOMER REPORTED THAT THE TUBING DISCONNECTED FROM THE STOPCOCK AND LEAKED WHILE ANESTHESIA WAS INDUCING A PATIENT. THIS RESULTED IN ADMINISTERING MORE SEDATION MEDICATION TO THE PATIENT. THERE WAS NO PATIENT HARM.

    Patient problems: Inadequate Pain Relief

    MAUDE report 8076484 ↗
  • MalfunctionNov 9, 2018Disconnection; Fluid/Blood Leak; Disconnection; Fluid/Blood Leak

    THE CUSTOMER REPORTED THAT THE TUBING DISCONNECTED FROM THE STOP COCK CAUSING THE PATIENT TO BLEED BACK UP INTO THE LINE AND ONTO THE FLOOR DURING AN OPERATING ROOM CASE. THERE WAS NO HARM.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 8057377 ↗

Other Set, administration, intravascular devices

All Set, administration, intravascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page