Alaris, SmartSite 10404198Recalls & reported problems

BD Switzerland Sàrl · Pump Infusion Set, Back Check Valve, 3 Y-Sites 389 cm (153 in) · Class 2

All models of Alaris, SmartSite (160)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10885403232527), received between Mar 27, 2018 and Mar 27, 2018 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Break1
  • Detachment Of Device Component1
  • Failure to Deliver1
  • Failure to Prime1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 27, 2018Break; Detachment Of Device Component; Failure to Prime; Failure to Deliver

    COLLECTIVELY OVER THE PAST WEEK OR SO WE'VE HAD 10 INFUSION SETS AT ISSUE (SEE DESCRIPTIONS BELOW). THERE WAS NO PATIENT HARM SO THERE IS NO PATIENT INFORMATION IN THIS REPORT. ALL BUT ITEM 1 WERE ISSUES WITH NON-PRIMING CAPABILITIES; 3 OF WHICH WERE FROM EMERGENCY ROOM AND SIX WERE FROM PEDIATRICS/L&D. SINCE THE REFERENCE NUMBERS AND ID NUMBERS WERE IDENTICAL ON THE SAVED DEVICES THE CONSENSUS WAS TO GET THE FDA NOTIFIED OF THE TREND. 1. PUMP TUBING BROKE WHILE IN EMERGENCY PATIENT WAS IN CT. THE BLUE PIECE SNAPPED RIGHT AT THE END OF THE INFUSION. THE TUBING WAS NOT BEING PULLED ON IN ANY WAY; WE WERE IN THE CONTROL ROOM AND THE PUMP SAID INFUSION COMPLETE AND THEN SECONDS LATER THE TUBING SNAPPED LOOSE FROM THE TOP OF PUMP AND SHOT UP IN AIR AND DUMPED THE LAST LITTLE BIT OF ABX ONTO THE BED. 2, 3, & 4. MANY PUMP TUBINGS IN THE EMERGENCY ROOM HAVE PROBLEMS WITH INITIAL PRIMING OF LINE. FREE FLOW DOES NOT OCCUR UNTIL SOME PRESSURE IS APPLIED TO CAUSE THE BACKFLOW VALVE TO "POP" OPEN INTERNALLY. 5 & 6 FROM L&D AND 7-10 PEDIATRICS WITH THE SIMILAR ISSUE: IV TUBING WOULD NOT PRIME AND PUMP WAS UNABLE TO INFUSE IV FLUIDS. PUMP TUBING CHANGED 3 TIMES AND PUMP CHANNEL CHANGED TWICE.N

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7373269 ↗

Other Set, administration, intravascular devices

All Set, administration, intravascular devices →