Skip to content

BD Pyxis 1148-00Recalls & reported problems

Carefusion 303, Inc. · BD Pyxis MedBank Mini Auxiliary · Class 1

All models of BD Pyxis (26)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 10885403517198), received between Jun 30, 2025 and May 11, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Communication or Transmission Problem” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 1 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Sep 30, 2025Open, Classified

    Potential fluid ingress of anesthesia station or med station may result in smoke, system downtime and/or fire.

    Z-0367-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Communication or Transmission Problem1
  • Failure to Eject1

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 11, 2026Communication or Transmission Problem

    IT WAS REPORTED THAT WHEN USING THE BD PYXIS¿ MEDBANK MINI AUX, CABINET WAS OFFLINE AND NOT SYNCHRONIZING WITH MYQLINK. THE CUSTOMER ATTEMPTED TO ISSUE A NARCOTIC THAT REQUIRES AN RXVERIFY CODE. THE CUSTOMER STATED THAT THIS MALFUNCTION OCCURRED WHILE DISPENSING THE MEDICATION. THERE WERE NO ADVERSE EVENTS OR INJURIES REPORTED BASED ON THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25135906 ↗
  • MalfunctionJun 30, 2025Failure to Eject; Failure to Eject

    IT WAS REPORTED BY THE CUSTOMER THAT BD PYXIS¿ MEDBANK MINI AUX WAS NOT ABLE TO PULL HYDROCHLOROTHIAZIDE (HCTZ) 25 MG TAB IN PROFILE, DESPITE USING OVERRIDE FUNCTION. PROFILE AMOUNT IS SET TO 0.5 AND SHOULD BE A WHOLE NUMBER. USER WILL CONTACTED THE PHARMACY FOR ASSISTANCE ON THAT MED ORDER. THERE WERE NO ADVERSE EVENTS OR INJURIES REPORTED BASED ON THIS INCIDENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22354307 ↗

Other CABINET, TABLE AND TRAY, ANESTHESIA devices

All CABINET, TABLE AND TRAY, ANESTHESIA devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page