ENVOY 556-256-00Recalls & reported problems
Cerenovus, Inc. · ENVOY Guiding Catheter MPC 100 cm 5F (1.65 mm) .056 Inch (1.4 mm) · Class 2
All models of ENVOY (15)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 10886704027935), received between Aug 20, 2020 and Oct 13, 2020 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Fluid/Blood Leak3
Patient problems
- No Consequences Or Impact To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionOct 13, 2020Fluid/Blood Leak; Fluid/Blood Leak
AS REPORTED BY THE FIELD, DURING A CEREBRAL ANGIOGRAPHY, ASPIRATION AIR CAME IN AND DURING INJECTION WATER CAME OUT AT THE BEGINNING OF ON AN ENVOY 5F, MPC 100 CM CATHETER (55625600, 30247204). THERE WAS A PROCEDURAL DELAY OF FIVE MINUTES DUE TO THE EVENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT INJURY REPORTED. ADDITIONAL INFORMATION CLARIFIED THAT THE ASPIRATION WAS ¿RIGHT¿, THE CATHETER SUCK AIR BETWEEN THE HUB. THE DEVICE DID NOT APPEAR KINKED, COMPRESSED, CRACKED OR HAD ANY OTHER DAMAGE. THERE WAS NO EVIDENCE OF AIR BEING INJECTED INTO THE PATIENT DUE TO THE LEAKAGE. NO EXCESSIVE FORCE WAS APPLIED TO THE DEVICE. THE TARGET VESSEL/SITE WAS THE RIGHT VERTEBRAE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10670940 ↗MalfunctionAug 20, 2020Fluid/Blood Leak; Fluid/Blood Leak
AS REPORTED BY THE FILED, DURING A CEREBRAL ANGIOGRAPHY, ASPIRATION AIR CAME IN AND DURING INJECTION WATER CAME OUT AT THE BEGINNING OF ON AN ENVOY 5F, MPC 100 CM CATHETER (55625600, 30247204). THERE WAS A PROCEDURAL DELAY OF FIVE MINUTES DUE TO THE EVENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT INJURY REPORTED. ADDITIONAL INFORMATION CLARIFIED THAT THE ASPIRATION WAS ¿RIGHT¿, THE CATHETER SUCK AIR BETWEEN THE HUB. THE DEVICE DID NOT APPEAR KINKED, COMPRESSED, CRACKED OR HAD ANY OTHER DAMAGE. THERE WAS NO EVIDENCE OF AIR BEING INJECTED INTO THE PATIENT DUE TO THE LEAKAGE. NO EXCESSIVE FORCE WAS APPLIED TO THE DEVICE. THE TARGET VESSEL WAS THE RIGHT CAROTID.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10431087 ↗MalfunctionAug 20, 2020Fluid/Blood Leak; Fluid/Blood Leak
AS REPORTED BY THE FILED, DURING A CEREBRAL ANGIOGRAPHY, ASPIRATION AIR CAME IN AND DURING INJECTION WATER CAME OUT AT THE BEGINNING OF ON AN ENVOY 5F, MPC 100 CM CATHETER (55625600, 30289560). THERE WAS A PROCEDURAL DELAY OF FIVE MINUTES DUE TO THE EVENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT INJURY REPORTED. ADDITIONAL INFORMATION CLARIFIED THAT THE ASPIRATION WAS ¿RIGHT¿, THE CATHETER SUCK AIR BETWEEN THE HUB. THE DEVICE DID NOT APPEAR KINKED, COMPRESSED, CRACKED OR HAD ANY OTHER DAMAGE. THERE WAS NO EVIDENCE OF AIR BEING INJECTED INTO THE PATIENT DUE TO THE LEAKAGE. NO EXCESSIVE FORCE WAS APPLIED TO THE DEVICE. THE TARGET VESSEL/SITE WAS THE RIGHT VERTEBRATE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10430936 ↗
Other CATHETER, PERCUTANEOUS devices
- WATCHMAN FXD Curve™ Access System M635TU80020Boston Scientific Corporation · Catheter, percutaneous1 recall47 deaths654 reports
- NA C315HIS02Medtronic, Inc. · Catheter, percutaneous1 recall369 reports
- WATCHMAN TruSteer™ Access System M635TU90050Boston Scientific Corporation · Catheter, percutaneous1 recall28 deaths302 reports
- Guidezilla™ II H7493933515060Boston Scientific Corporation · CATHETER, PERCUTANEOUS1 recall3 deaths278 reports
- Velocity Delivery Microcatheter VEL160STR-APenumbra, Inc. · CATHETER, PERCUTANEOUS297 reports
- Guidezilla™ H7493924215050Boston Scientific Corporation · CATHETER, PERCUTANEOUS294 reports
- WATCHMAN™ TruSeal™ Access System M635TU70020Boston Scientific Corporation · Catheter, percutaneous1 recall11 deaths217 reports
- Lantern Delivery Catheter PXSLIMLAN135T45Penumbra, Inc. · CATHETER, PERCUTANEOUS220 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.