ENVOYRecalls & reported problems across all models
Cerenovus, Inc. · 15 models in the FDA device registry
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 39
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls
- 0
We found 15 models of ENVOY by Cerenovus, Inc. in the FDA's device registry (GUDID). Together they are named in 39 adverse event reports in the FDA's MAUDE database, received between Jun 14, 2017 and Jun 16, 2026 — classified as 5 injuries, 34 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event. Widely used products collect more reports, so totals can't be used to compare products or estimate failure rates. Only reports that name a model's exact device identifier are counted. What reports can and can't tell you · How this data works
Reports received per month, all models
Most reported ENVOY problems
Device problems
- Fluid/Blood Leak7
- Material Twisted/Bent6
- Contamination /Decontamination Problem5
- Crack5
- Physical Resistance/Sticking5
- Material Separation3
- Split3
- Tear, Rip or Hole in Device Packaging3
Patient problems
- No Clinical Signs, Symptoms or Conditions24
- No Consequences Or Impact To Patient11
- Vasoconstriction2
- Injury1
- Insufficient Information1
- No Code Available1
ENVOY models
15 models, most reported first. Each model has its own page with its reports, recalls and device details.
- ENVOY 670-258-00CATHETER, PERCUTANEOUS12 reports
- ENVOY 670-258-90CATHETER, PERCUTANEOUS4 reports
- ENVOY 556-256-00CATHETER, PERCUTANEOUS3 reports
- ENVOY 670-256-00CATHETER, PERCUTANEOUS3 reports
- ENVOY 670-256-00BCATHETER, PERCUTANEOUS3 reports
- ENVOY 670-256-90BCATHETER, PERCUTANEOUS3 reports
- ENVOY 670-256-90CATHETER, PERCUTANEOUS2 reports
- ENVOY 670-260-90CATHETER, PERCUTANEOUS2 reports
- ENVOY 556-258-00CATHETER, PERCUTANEOUS1 report
- ENVOY 556-258-90CATHETER, PERCUTANEOUS1 report
- ENVOY 670-252-90CATHETER, PERCUTANEOUS1 report
- ENVOY 670-258-90BCATHETER, PERCUTANEOUS1 report
- ENVOY 670-260-00BCATHETER, PERCUTANEOUS1 report
- ENVOY 778-258-90CATHETER, PERCUTANEOUS1 report
- ENVOY 778-252-90CATHETER, PERCUTANEOUS1 report
Recent ENVOY adverse event reports
The 15 most recent reports across all models, in the reporter's own words as published by the FDA.
MalfunctionJun 16, 2026Material Twisted/Bent; Physical Resistance/Sticking
A HEALTHCARE PROFESSIONAL REPORTED THAT DURING A COIL EMBOLIZATION, AN ENVOY 6F, MPD 100CM GUIDE CATHETER (PRODUCT CODE: 67025800, LOT NUMBER: 31312323) WAS DELIVERED IN PLACE AND THEN AN UNSPECIFIED MICROCATHETER (MC) WAS DELIVERED IN THE GUIDE CATHETER. THE MICROCATHETER WAS IMPEDED IN THE DISTAL END OF THE GUIDE CATHETER AND COULD NOT PASS THROUGH THE GUIDE CATHETER. THE DOCTOR REMOVED THE GUIDE CATHETER AND MICROCATHETER FROM THE PATIENT, THE GUIDE CATHETER TIP WAS FOUND KINKED/BENT. THE DOCTOR SWITCHED TO A NEW GUIDE CATHETER TO COMPLETE SURGERY WITH THE ORIGINAL MICROCATHETER. THE SURGERY WAS PROLONGED BY ABOUT 10 MINUTES. PRIOR TO THE PROCEDURE, THE DEVICE OUTER PACKAGING AND THE DEVICE WERE INSPECTED AND FOUND IN GOOD CONDITION. ADDITIONAL EVENT INFORMATION RECEIVED ON 08-JUN-2026 INDICATED THAT THERE WAS FLUSHING DURING THE PROCEDURE. THERE WAS NO EVIDENCE OF PHYSICAL MATERIAL WITHIN THE DEVICE. THERE WAS NO EXCESSIVE FORCE USED WITH THE DEVICES. THERE WAS PROCEDURE PROLONGATION/DELAY DUE TO THE EVENT, HOWEVER, IT DID NOT RESULT IN A PATIENT ADVERSE CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 25523430 ↗MalfunctionFeb 23, 2026Contamination /Decontamination Problem; Physical Resistance/Sticking
ON (B)(6) 2026, DURING AN EMBOLIZATION PROCEDURE TARGETING THE MIDDLE MENINGEAL ARTERY, UPON THE INSERTION OF THE 6F 90 CM, STRAIGHT ENVOY® GUIDING CATHETER (67026090 / 31740728), THERE WAS STRONG RESISTANCE BETWEEN THE ENVOY AND THE INNER CATHETER STARTING AROUND THE OPHTHALMIC ARTERY (AO). CONTINUOUS FLUSH WAS MAINTAINED. THE VESSEL COURSE WAS TORTUOUS. WHEN THE ENVOY WAS WITHDRAWN, AN UNIDENTIFIED MATERIAL WAS FOUND ATTACHED TO IT. THE ENVOY WAS REPLACED WITH A NEW ENVOY OF THE SAME SIZE, AND THE REPLACEMENT ENVOY CATHETER WAS USED WITH THE SAME INNER CATHETER WITHOUT ANY PROBLEMS. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO NEGATIVE IMPACT TO THE PATIENT. ON 09-FEB-2026, ADDITIONAL INFORMATION WAS RECEIVED. THE INFORMATION PROVIDED INCLUDES THE PHYSICIAN¿S COMMENTS ON THE REPORTED ISSUE AND DETAILS RELATED TO THE PROCEDURE. ¿THE AORTIC TORTUOSITY APPEARED TO HAVE SEVERAL MARKEDLY TORTUOUS SEGMENTS, WHICH I BELIEVE WAS ONE OF THE FACTORS CAUSING RESISTANCE DURING CATHETER INSERTION. THE TORTUOSITY AT THE [COMMON CAROTID ARTERY] CCA ORIGIN WAS SUCH THAT IT BENT ABOUT 90 DEGREES IMMEDIATELY AFTER ITS ORIGIN, AND I THOUGHT THIS WAS FAIRLY PRONOUNCED. THE INNER CATHETER U
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24415999 ↗InjuryFeb 19, 2026Difficult to Remove; Material Separation
IT WAS REPORTED, VIA EMAIL, THAT AN ENVOY, 7F, 90 CM, SIMMONS 2 (77825290/ 31708615) WAS USED FOR A MECHANICAL THROMBECTOMY PROCEDURE. DURING THE PROCEDURE, THE USER REPORTED ENVOY CATHETER- WITHDRAWAL DIFFICULTY FROM VESSEL AND SEPARATION WHILE IN PATIENT. THE PHYSICIAN USED A ZOOM55 REPERFUSION CATHETER (IMPERATIVE CARE, INC.) INSIDE THE ENVOY AND HAD AN 8FR SHEATH (UNSPECIFIED BRAND) FOR FEMORAL ACCESS. DUE TO SEVERE VESSEL TORTUOSITY, THE USER WAS ¿UNABLE TO SELECT TO ADVANCE.¿ THE PHYSICIAN DECIDED TO WITHDRAW THE ENVOY CATHETER BUT EXPERIENCED DIFFICULTY/RESISTANCE. ¿CATHETER DISTALLY BROKE OFF AND REMAINED INSIDE PATIENT.¿ THE EVENT WAS INITIALLY REPORTED AS SUCH, ¿AFTER TRYING TO SELECT IN A TYPE III ARCH WITH VERY TORTUOSITY VESSELS, UNABLE TO SELECT TO ADVANCE. WHEN, PHYSICIAN DECIDED TO PULL THE 7FR ENVOY CATHETER SIM 2 BY 90CM LENGTH, IT WAS HARD TO PULL CATHETER. CATHETER DISTALLY BROKE OFF AND REMAINED INSIDE PATIENT. PHYSICIAN HAD USED A ZOOM 55 INSIDE THE ENVOY AND HAD AN 8FR SHEATH FOR FEMORAL ACCESS.¿ ON 14-FEB-2026, ADDITIONAL EVENT INFORMATION WAS RECEIVED FROM THE SALES REPRESENTATIVE. SUMMARY: PER THE INFORMATION PROVIDED, IT WAS CONFIRMED THAT THE CATHETER ST
Patient problems: Insufficient Information
MAUDE report 24388305 ↗MalfunctionFeb 2, 2026Crack; Material Twisted/Bent
IT WAS REPORTED, VIA EMAIL, THAT AN ENVOY 6F, XB MPD 90CM (67025890B / 31663293), WAS TO BE USED FOR A CAROTID STENTING PROCEDURE. DURING THE PROCEDURE, THE USER REPORTED A KINK AND A CRACK OF THE ENVOY. THE EVENT WAS INITIALLY REPORTED AS SUCH, ¿THE PRODUCT ARRIVED BROKEN IN ITS ORIGINAL PACKAGING. THE PRODUCT WAS INTENDED FOR USE IN A CAROTID STENTING PROCEDURE, BUT DUE TO DAMAGE TO THE PRODUCT, IT WAS NOT USED IN THE PATIENT, CAUSING A DELAY IN THE PROCEDURE. THE DEVICE HAS BENDING/BREAKAGE. THE DAMAGE WAS NOTICED BEFORE THE PRODUCT WAS USED ON THE PATIENT. NOTHING WAS OBSTRUCTING THE CATHETER. THE CATHETER WAS NOT FLUSHED. NO PATIENT HARM WAS REPORTED. NO FURTHER INFORMATION WAS MADE AVAILABLE AT THE TIME OF THIS REVIEW.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24234375 ↗MalfunctionJan 20, 2026Material Twisted/Bent; Physical Resistance/Sticking
A HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN ENDOVASCULAR EMBOLIZATION PROCEDURE, AN ENVOY 6F, MPD 100CM (PRODUCT CODE 67025800, LOT NUMBER 31438233) BECOME OBSTRUCTED AND KINKED/BENT. DURING THE PROCEDURE, THE GUIDE CATHETER WAS DELIVERED IN PLACE, FOLLOWED BY THE UNSPECIFIED MICROCATHETER (MC). THE MICROCATHETER WAS IMPEDED AT THE DISTAL END OF THE GUIDE CATHETER AND COULD NOT PASS THROUGH. BOTH THE GUIDE CATHETER AND MICROCATHETER WERE REMOVED, AND THE DISTAL TIP OF THE GUIDE CATHETER WAS OBSERVED TO BE KINKED OR BENT. THE PROCEDURE WAS COMPLETED USING A NEW GUIDE CATHETER FROM ANOTHER BRAND WITH THE ORIGINAL MICROCATHETER. THERE WAS NO REPORTED PATIENT CONSEQUENCE OR INVOLVEMENT. THE DEVICE'S OUTER PACKAGING AND THE DEVICE ITSELF WERE INSPECTED PRIOR TO USE AND FOUND TO BE IN GOOD CONDITION. NO ADDITIONAL INFORMATION IS AVAILABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24116813 ↗MalfunctionNov 14, 2025Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging
THE DISTRIBUTOR RECEIVED 3 BOXES THAT APPEARED TO HAVE BEEN OPENED, ENVOY 6F, XB MPC 100CM (67025600B / 31675240). A PERSON FROM THE QUALITY TEAM WENT TO INSPECT THE PRODUCTS INSIDE. THE PRODUCTS AND THEIR INTERNAL PACKAGING DO NOT APPEAR TO BE DAMAGED. ADDITIONAL INFORMATION WAS RECEIVED ON 10/21/2025 STATING THAT THE PRODUCTS INSIDE THE BOXES WERE INTACT, AND CONFIRMING THERE WAS DAMAGE TO THE SHIPPING BOX, THE SHIPPING CARTON WAS TORN RIGHT AT THE 3 OPEN BOXES, AS IF SOMEONE HAD OPENED THE CARTON TO SEE WHAT WAS INSIDE. UNFORTUNATELY, THEIR LOGISTICS DEPARTMENT DISCARDED THE SHIPPING CARTON BEFORE TAKING PICTURES OF THE OPEN BOXES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23554596 ↗MalfunctionNov 14, 2025Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging
THE DISTRIBUTOR RECEIVED 3 BOXES THAT APPEARED TO HAVE BEEN OPENED, ENVOY 6F, XB MPC 100CM (67025600B / 31675240). A PERSON FROM THE QUALITY TEAM WENT TO INSPECT THE PRODUCTS INSIDE. THE PRODUCTS AND THEIR INTERNAL PACKAGING DO NOT APPEAR TO BE DAMAGED. ADDITIONAL INFORMATION WAS RECEIVED ON 10/21/2025 STATING THAT THE PRODUCTS INSIDE THE BOXES WERE INTACT, AND CONFIRMING THERE WAS DAMAGE TO THE SHIPPING BOX, THE SHIPPING CARTON WAS TORN RIGHT AT THE 3 OPEN BOXES, AS IF SOMEONE HAD OPENED THE CARTON TO SEE WHAT WAS INSIDE. UNFORTUNATELY, THEIR LOGISTICS DEPARTMENT DISCARDED THE SHIPPING CARTON BEFORE TAKING PICTURES OF THE OPEN BOXES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23554557 ↗MalfunctionNov 14, 2025Tear, Rip or Hole in Device Packaging; Tear, Rip or Hole in Device Packaging
THE DISTRIBUTOR RECEIVED 3 BOXES THAT APPEARED TO HAVE BEEN OPENED, ENVOY 6F, XB MPC 100CM (67025600B / 31675240). A PERSON FROM THE QUALITY TEAM WENT TO INSPECT THE PRODUCTS INSIDE. THE PRODUCTS AND THEIR INTERNAL PACKAGING DO NOT APPEAR TO BE DAMAGED. ADDITIONAL INFORMATION WAS RECEIVED ON 10/21/2025 STATING THAT THE PRODUCTS INSIDE THE BOXES WERE INTACT, AND CONFIRMING THERE WAS DAMAGE TO THE SHIPPING BOX, THE SHIPPING CARTON WAS TORN RIGHT AT THE 3 OPEN BOXES, AS IF SOMEONE HAD OPENED THE CARTON TO SEE WHAT WAS INSIDE. UNFORTUNATELY, THEIR LOGISTICS DEPARTMENT DISCARDED THE SHIPPING CARTON BEFORE TAKING PICTURES OF THE OPEN BOXES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23554501 ↗MalfunctionJun 17, 2025Physical Resistance/Sticking; Physical Resistance/Sticking
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING A STENT-ASSISTED ANEURYSM EMBOLIZATION PROCEDURE TARGETING AN ANEURYSM AT THE BIFURCATION OF THE MIDDLE CEREBRAL ARTERY, AN ENVOY® GUIDING CATHETER, 6F, 100 CM, MPD (67025800 / 31312321) WAS DELIVERED IN PLACE AND THEN THE 150CM X 5CM PROWLER SELECT PLUS MICROCATHETER (606S255X / LOT# UNKNOWN) WAS DELIVERED IN THE GUIDE CATHETER. THE MICROCATHETER WAS IMPEDED IN THE MIDDLE SECTION OF THE GUIDE CATHETER BUT IT STILL PASSED THROUGH THE GUIDE CATHETER AND WAS DELIVERED TO THE TARGET. LATER IN THE PROCEDURE, THE 4MM X 23MM NO TIP ENTERPRISE¿ 2 VASCULAR RECONSTRUCTION DEVICE (ENCR402300 / 9368822) WAS IMPEDED IN THE DISTAL END OF THE MICROCATHETER AND COULD NOT PASS THROUGH IT. THE PHYSICIAN REMOVED ALL THREE DEVICES FROM THE PATIENT AND REPLACED THE GUIDE CATHETER AND THE STENT TO COMPLETE THE PROCEDURE USING THE SAME MICROCATHETER. THERE WAS NO NEGATIVE IMPACT ON THE PATIENT. ON 16-JUN-2025, IT WAS INDICATED THAT ADDITIONAL INFORMATION CANNOT BE OBTAINED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22237673 ↗MalfunctionFeb 12, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem
AS REPORTED BY THE FIELD, BOTH ENVOY 6F, MPC 100CM CATHETERS (67025600, 31027256) HAD PROTRUDING PLASTIC RESIDUES FROM PRODUCTION ON THE THREADED PIECE. THE PROFESSOR DID NOT WANT TO USE THEM DUE TO THE RISK OF EMBOLIZATION. WE NOTICED THIS PROBLEM WHEN UNPACKING, SO THERE IS NO RISK OF INFECTION. NO PATIENT INJURY AS THE DEVICES WERE NOT CLINICALLY USED. ADDITIONAL EVENT INFORMATION RECEIVED ON 12-FEB-2025 INDICATED THAT THE POUCHES WERE SEALED PRIOR TO BEING OPENED. THERE WAS NOT BEEN ANY PACKAGING ISSUES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21364576 ↗MalfunctionFeb 12, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem
AS REPORTED BY THE FIELD, BOTH ENVOY 6F, MPC 100CM CATHETERS (67025600, 31027256) HAD PROTRUDING PLASTIC RESIDUES FROM PRODUCTION ON THE THREADED PIECE. THE PROFESSOR DID NOT WANT TO USE THEM DUE TO THE RISK OF EMBOLIZATION. WE NOTICED THIS PROBLEM WHEN UNPACKING, SO THERE IS NO RISK OF INFECTION. NO PATIENT INJURY AS THE DEVICES WERE NOT CLINICALLY USED. ADDITIONAL EVENT INFORMATION RECEIVED ON 12-FEB-2025 INDICATED THAT THE POUCHES WERE SEALED PRIOR TO BEING OPENED. THERE WAS NOT BEEN ANY PACKAGING ISSUES.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21364536 ↗MalfunctionJan 24, 2025Crack; Crack
AS REPORTED BY THE FIELD, WHEN UNPACKING THE ENVOY CATHETER (77825890, 31253144) THE HEALTH CARE PROFESSIONAL (HCP), NOTICED THAT IT WAS TORN AT THE TOP OF THE HUB AND THEN PLACED IT ON ITS SIDE. ADDITIONAL EVENT INFORMATION RECEIVED ON 23-JAN-2025 INDICATED THAT THE DEVICE WAS STORED AND HANDLED ACCORDING TO THE INSTRUCTIONS FOR USE (IFU). THERE WAS NO DAMAGE NOTED TO THE PACKAGING. THE INTEGRITY OF THE STERILE POUCH WAS NOT COMPROMISED. THERE WERE NO PROCEDURAL DELAYS DUE TO THE EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21230911 ↗MalfunctionDec 26, 2024Material Puncture/Hole; Material Puncture/Hole
THE HEALTHCARE PROFESSIONAL REPORTED THAT THERE WAS A ¿HOLE IN THE CATHETER.¿ THE CATHETER REPORTED WAS AN ENVOY® XB GUIDING CATHETER (67026000B / 31189199). THE ISSUE WAS OBSERVED PRIOR TO THE PROCEDURE. THERE WAS NO PATIENT INVOLVEMENT. ON 12-DEC-2024, ADDITIONAL INFORMATION WAS RECEIVED. PER THE INFORMATION, THE ISSUE OCCURRED ON (B)(6) 2024 PRE-OP TO A CEREBRAL DIAGNOSTIC PROCEDURE. THE ENVOY WAS REPLACED WITH ANOTHER ENVOY GUIDING CATHETER. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO NEGATIVE PATIENT IMPACT AND NO DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21019793 ↗MalfunctionDec 4, 2024Fluid/Blood Leak; Fluid/Blood Leak
AS REPORTED BY THE FIELD, THERE WAS A HUB LEAKAGE ON AN ENVOY 5F, MPD 90CM CATHETER (55625890, 31189193) WHEN IT WAS OPENED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20843990 ↗MalfunctionNov 5, 2024Fluid/Blood Leak; Fluid/Blood Leak
THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN INTERVENTIONAL ENDOVASCULAR PROCEDURE TARGETING AN ARTERIOVENOUS MALFORMATION (AVM), THE PHYSICIAN WAS GAINING ACCESS TO THE ARTERY WHILE ADVANCING A 6F 90 CM, STRAIGHT ENVOY® GUIDING CATHETER (67026090 / 31040775) WHEN IT WAS NOTICED THAT BLOOD WAS LEAKING AROUND THE HUB OF THE CATHETER WHERE THE YELLOW HUB MEETS THE WHITE ID BAND. THE ENVOY WAS REMOVED AND REPLACED WITH A NEW ONE AND THE PROCEDURE WENT FORWARD SUCCESSFULLY. THERE WAS NO NEGATIVE IMPACT TO THE PATIENT. ON 04-NOV-2024, ADDITIONAL INFORMATION WAS RECEIVED. PER THE INFORMATION, THE LOCATION OF THE AVM AND VESSEL CHARACTERISTICS (VESSEL TORTUOSITY OR ACUTE BENDS) ARE NOT KNOWN. THE REPLACEMENT DEVICE WAS ANOTHER ENVOY (67026090).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20613941 ↗
Other Cerenovus, Inc. products
- GALAXY G358 models · 1,386 reports · 1 recall
- CODMAN41 models · 107 reports · 22 recalls
- MICRUSFRAME47 models · 298 reports
- DELTAFILL29 models · 294 reports
- CEREPAK FREEFORM60 models · 166 reports · 1 recall
- CEREBASE3 models · 143 reports · 1 recall
- DELTAXSFT13 models · 130 reports
- CEREPAK UNIFORM58 models · 33 reports · 1 recall
Sources and updates
- Models: FDA GUDID, file dated Oct 13, 2026. Models are grouped by the brand name the manufacturer registered.
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page