ORBIT GALAXY 640CF0815Recalls & reported problems

Medos International Sàrl · ORBIT GALAXY Detachable Coil System with Tight Distal Loop technology 175cm d=2/3D D=8mm 15cm Contents: 1 detachable coil system and 1 luer valve Coil Type: Complex Fill Note: ONLY use with TRUFILL DCS Syringe II. · Class 2

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704030379), received between Jul 31, 2026 and Jul 31, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Separation Failure” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Separation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 31, 2026Separation Failure

    The healthcare professional reported that during an endovascular embolization procedure, the 8mm x 30cm Complex Frame ((b)(4)) was impeded in the introducer sheath and could not be inserted into the associated microcatheter. The physician found that the proximal end of the introducer broke into two pieces; the physician then switched to a second coil to pack the aneurysm and successfully detached. A third coil, 8mm x 15cm Orbit Galaxy Complex Fill ((b)(4)) was used to pack the aneurysm, and it was found that the third coil was unable to be detached. The physician retracted the coil and replaced it with a fourth coil to complete the procedure using the original microcatheter. The procedure was prolonged by about 10 minutes. There was no report of any negative patient impact.On 24-Jul-2026, additional information was received. Per the information, the procedure was targeting the internal carotid artery. The third coil was still attached to the delivery system when it was removed. The syringe was filled with saline from a dedicated source. Before attempting to deploy the third coil, the syringe had previously exceeded the Green Zone/position 3. With the attempt to deploy the third coi

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50100851 ↗