ORBIT GALAXY 640CR2030Recalls & reported problems

Medos International Sàrl · ORBIT GALAXY Detachable Coil System with Tight Distal Loop technology 175cm d=2/3D D=20mm 30cm Contents: 1 Detachable Coil System with Tight Distal Loop technology and 1 luer valve. Coil Type: Complex Frame Note: ONLY use with TRUFILL DCS Syringe II. · Class 2

All models of ORBIT GALAXY (26)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704030522), received between Jul 31, 2025 and Jul 31, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Failure to Advance” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Advance1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 31, 2025Failure to Advance; Failure to Advance

    THE HEALTHCARE PROFESSIONAL REPORTED THAT DURING AN ENDOVASCULAR EMBOLIZATION PROCEDURE, AFTER ABOUT HALF OF THE 20MM X 30CM ORBIT GALAXY COMPLEX FRAME COIL (640CR2030 / 31122650) WAS FILLED IN THE ANEURYSM, THE COIL WAS FOUND TO BE IMPEDED IN THE CONCOMITANT MICROCATHETER TIP AND COULD NOT ADVANCE ANY FURTHER. THE PHYSICIAN RETRACTED ONLY THE COIL AND REPLACED IT WITH ANOTHER 20MM X 30CM ORBIT GALAXY COMPLEX FRAME COIL (640CR2030 / 31122650) AND DELIVERED THIS SECOND COIL, BUT THE SAME ISSUE WAS ENCOUNTERED; THE COIL ALSO BECAME IMPEDED IN THE MICROCATHETER. THE PHYSICIAN RETRACTED THIS COIL AND REPLACED IT WITH ANOTHER COIL (COMPETITOR BRAND) TO COMPLETE THE PROCEDURE USING THE SAME ORIGINAL MICROCATHETER (COMPETITOR BRAND). THE PROCEDURE WAS PROLONGED BY ABOUT 30 MINUTES BUT WAS SUCCESSFULLY COMPLETED. THERE WAS NO NEGATIVE IMPACT ON THE PATIENT. ON 01-JUL-2025, ADDITIONAL INFORMATION WAS RECEIVED. PER THE INFORMATION, THE TARGET VESSEL WAS THE OPHTHALMIC SEGMENT OF THE INTERNAL CAROTID ARTERY (ICA). THERE WAS CIRCUMFLEXION OF THE ICA PROXIMAL TO THE BLOOD VESSELS. THE CONCOMITANT MICROCATHETER WAS AN ECHELON¿ 14 MICROCATHETER (MEDTRONIC). NO OTHER DEVICES PASSED THROUGH THE MIC

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22683563 ↗

Other Device, Vascular, for Promoting Embolization devices

All Device, Vascular, for Promoting Embolization devices →