CEREPAK FREEFORM MCR092555Recalls & reported problems

Cerenovus, Inc. · CEREPAK FREEFORM Mini Detachable Coil Delivery System Length - 190 cm Coil Diameter - 2.5 mm Coil Length - 5.5 cm · Class 2 · Implant

All models of CEREPAK FREEFORM (60)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 10886704083047), received between Oct 25, 2023 and Oct 25, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Separation Failure” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 2, 2025Class IOpen, Classified

    Detachable coils system may fail to detach, which could result in hemorrhagic and ischemic stroke, procedural delays, or the need for additional surgical intervention.

    Z-0434-2026 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Separation Failure1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 25, 2023Separation Failure; Separation Failure

    AS REPORTED BY THE FIELD, DURING A COIL EMBOLIZATION TO THE MIDDLE MENINGEAL ARTERY, A FREEFORM MINI COIL 2.5MM X 5.5CM (MCR092555, 31073453) FAILED TO DETACH. THE COIL WAS ADVANCED USING STEPS PER THE INSTRUCTIONS FOR USE (IFU) INTO DETACHMENT POSITION IN THE POSTERIOR BRANCH OF THE MIDDLE MENINGEAL ARTERY USING A SL-10 STRAIGHT MICROCATHETER (MC). THE CEREPAK DETACHMENT HANDLE WAS USED 3 TIMES TO DETACH, ALL OF WHICH WERE UNSUCCESSFUL WITH VERIFICATION BY PULLING BACK ON THE DELIVERY SYSTEM UNDER FLUORO. THE MANUAL BREAK METHOD WAS THEN ATTEMPTED AFTER RE-ADVANCING THE COIL INTO DETACHMENT POSITION PER THE IFU. THIS METHOD TOO WAS UNSUCCESSFUL WITH VERIFICATION BY PULLING BACK ON THE DELIVERY SYSTEM UNDER FLUORO. THE COIL WAS THEN RETRACTED FROM THE PARENT VESSEL INTO THE SL-10 AND THE ENTIRE SYSTEM (COIL, DELIVERY SYSTEM AND MICROCATHETER WITH RHV) WERE REMOVED FROM THE PATIENT, PLACED ON THE BACK TABLE FOR INSPECTION AND PLACED INTO A BIOHAZARD BAG FOR RETURN TO CERENOVUS FOR ANALYSIS. THERE WERE NO PROCEDURAL DELAYS DUE TO THE EVENT. THE PROCEDURE WAS SUCCESSFULLY COMPLETED. THERE WAS NO PATIENT INJURY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18003305 ↗